AMX DX-TX-DWP Manual


Læs gratis den danske manual til AMX DX-TX-DWP (2 sider) i kategorien Ikke kategoriseret. Denne vejledning er vurderet som hjælpsom af 81 personer og har en gennemsnitlig bedømmelse på 4.5 stjerner ud af 41 anmeldelser. Har du et spørgsmål om AMX DX-TX-DWP, eller vil du spørge andre brugere om produktet?

Side 1/2
QUICK START GUIDE
DXLink™ Multi-Format Wallplate Transmitter and
DXLink™ Multi-Format Decor Style Wallplate Transmitter (US)
Overview
The DXLink Multi-Format Wallplate TX and DXLink Multi-Format Decor Style Wallplate TX
are used in conjunction with switchers that support DXLink Technology for transmission
of HDMI or analog video over twisted pair cable. Both TXs are compatible with the
DXLink HDMI RX and support InstaGate Pro® Technology. The Hardware Reference
Manual – DXLink Twisted Pair Transmitters /Receiver contains complete documentation
(including full specifications and supported input and output resolutions); for details,
see
www.amx.com.
Installation
System Setup
These Transmitters receive an HDMI signal (or DVI via a cable adapter) or an analog
video signal plus an audio signal from the source device. The audio can be either digital
audio embedded with the HDMI signal or analog stereo audio. Both the video and audio
are transmitted over twisted pair cable to a DXLink Input Board in a switcher that
supports DXLink Technology (see the example in FIG. 2). From the Input Board, the
signal can be routed through an output board. If the output board is a DXLink Output
Board, a DXLink HDMI RX is required between the board and the destination.
DIP Switch #3 Toggle
Before mounting the Transmitter – If a network connection is required, DIP switch #3
Toggle must be set to ON. #3 Toggle is shipped in the OFF position. When flipped ON
(up), the Transmitter will attempt a DHCP connection. Flipping the #3 Toggle ON is the
only way to access the Wallplate TX and Decor TX in NetLinx Studio. For both types of
Transmitters, #1, #2, and #4 Toggles are non-functional (must remain OFF). For
Auto-setup with an Enova DGX 100 Series Switcher, set #3 Toggle to OFF and see the
switcher’s manual.
IP Addressing Modes
DHCP Mode (enabled when #3 Toggle is flipped ON)
In DHCP Mode, the Transmitter attempts to get a DHCP lease (consisting of an IP
address, gateway, and other network parameters). If the attempt fails, the Transmitter
configures itself for a link-local address, but periodically re-tries DHCP and re-assigns
the IP to a valid DHCP grant if successful. At any time, if the Transmitter determines
that its IP address has changed, it will disconnect and reconnect to the Master.
Static IP Mode (set with ID button or Telnet command)
With #3 Toggle set to ON, press ID for 10 seconds to assign an address of 192.168.1.2
or use a Telnet command to set unit to Static IP Mode (see the Hardware Reference
Manual).
Mounting the Wallplate TX and Decor Wallplate TX
Wallplate TX – The holes in the Wallplate TX mounting bracket are designed to
accommodate a variety of gang boxes using 2 or 4 screws (standard and metric are
provided). Be sure to orient mounting bracket as shown in FIG. 4.
Decor Wallplate TX – The Decor Wallplate TX mounts into a standard US double-gang
back box. Decor style front cover plate is customer provided.
Technical Ground
If the system is experiencing problems with delivery of DXLink signals to/from an Enova
DGX Digital Media Switcher or Enova DVX Solution, adding a ground wire from the TX/
RX to the switcher may improve performance (see FIG. 7 on the next page). Technically
this type of grounding is only required when a DXLink Transmitter or Receiver is
connected to an ungrounded device, but this added grounding measure can be used at
the discretion of the installer (for instructions, see the Hardware Reference Manual).
Twisted Pair Cable Pinouts and RJ-45 LEDs
The DXLink port (RJ-45 connector) on the rear of the Transmitters uses twisted pair
cable. FIG. 5 shows two pinouts that can be used. FIG. 6 shows LEDs for the port.
Before installing the Transmitter:
Wallplate TX – remove mounting bracket.
If a network connection is required, set #3 Toggle to ON.
If gang box is not already installed, install it now.
To install the Wallplate Tx:
1. Attach the Wallplate TX mounting bracket to the gang box.
2. Attach a twisted pair cable from the DXLink Input Board on the switcher through
the mounting bracket to the DXLink connector on rear of Wallplate TX (FIG. 7).
3. Reattach the unit to the mounting bracket.
To install the Decor Wallplate TX:
1. Attach a twisted pair cable from the DXLink Input Board on the switcher to the
DXLink connector on the rear of the Decor Wallplate TX.
2. Attach unit to back box with four screws through the large screw holes.
3. Check LEDs for normal display (see table on the next page).
FIG. 1
WALLPLATE TX: FG1010-320-WH (LEFT) AND DECOR TX: FG1010-325-WH (RIGHT)
FIG. 2 WALLPLATE TX (FRONT & REAR) USED W/DXLINK INPUT BOARD IN ENOVA DGX 16
FIG. 3 DIP SWITCH ON REAR OF WALLPLATE TX (LEFT); ON FRONT OF DECOR TX (RIGHT)
Both available
in white (WH)
and black (BL)
Twisted pair cable
HDMI cable
Enova DGX 16
Source device
DXLink
Multi-Format
Wallplate TX
(Front) (Rear)
DXLink
Input Board
DIP switch
FIG. 4
WALLPLATE TX MOUNTING BRACKET
FIG. 5 RJ-45 CONNECTOR PINOUTS
FIG. 6 DXLINK PORT LEDS
Wallplate TX
mounting bracket
Use screw holes indicated with “X”s below:
US flush mount inside wall
EU flush mount inside wall
UK surface mount exterior wall or
UK flush mount inside wall
Green LED
On - Connection is active
Off - Connection is not active
Yellow LED
On - Authenticated HDCP
Blinking - Video active; no HDCP
Off - No Video
Wallplate TX
Decor Wallplate TX


Produkt Specifikationer

Mærke: AMX
Kategori: Ikke kategoriseret
Model: DX-TX-DWP
Type: AV sender
Bredde: 103.1 mm
Dybde: 88.4 mm
Højde: 57.2 mm
Vægt: 340 g
Antal pr. pakke: 1 stk
Produktfarve: Sort
Opbevaringstemperatur (T-T): -30 - 70 °C
Relativ luftfugtighed ved drift (H-H): 5 - 85 %
Relativ luftfugtighed ved opbevaring (H-H): 0 - 90 %
HDCP: Ja
Driftstemperatur (T-T): 0 - 40 °C
Maksimal opløsning: 1920 x 1200 pixel
Forbindelsesteknologi: Ledningsført
LED-indikatorer: Ja
Antal USB-porte: 1
Lydindgang: 1
Maksimal overførselsafstand: 100 m
Maksimal opdateringshastighed: 60 Hz
USB-stik type: Mini-USB B
HSMI-indgang: 1
VGA (D-Sub) indgangsporte: 1
Understøttede kabeltyper: Cat6, Cat6a, Cat7
Båndbredde: 10.2 Gbit/sek.

Har du brug for hjælp?

Hvis du har brug for hjælp til AMX DX-TX-DWP stil et spørgsmål nedenfor, og andre brugere vil svare dig




Ikke kategoriseret AMX Manualer

AMX

AMX NMX-DEC-N1233A Manual

26 November 2025
AMX

AMX DGX-O-DXF-MMS Manual

14 September 2025
AMX

AMX DVX-2250HD Manual

14 September 2025
AMX

AMX Vision² Manual

14 September 2025
AMX

AMX NMX-ENC-1100 Manual

14 September 2025
AMX

AMX UPC20+ Manual

14 September 2025
AMX

AMX DGX-I-DXL Manual

14 September 2025
AMX

AMX DGX-O-HDMI Manual

14 September 2025
AMX

AMX EXB-MP1 Manual

14 September 2025
AMX

AMX DGX-I-DXF-SMD Manual

14 September 2025

Ikke kategoriseret Manualer

Nyeste Ikke kategoriseret Manualer

Vevor

Vevor LX-PMMA-24*36 Manual

29 November 2025
Twelve South

Twelve South BookBook Manual

29 November 2025
Vevor

Vevor SSH-1S-100-2 Manual

29 November 2025
Vevor

Vevor GYZU-6T Manual

29 November 2025
Vevor

Vevor H10263-57 Manual

29 November 2025
Yamaha

Yamaha PLG150-DR Manual

29 November 2025
Extech

Extech 380460 Manual

29 November 2025
Blumfeldt

Blumfeldt Versagrow Manual

29 November 2025
Vevor

Vevor EVS-15L Manual

29 November 2025