Installation Guide Smart-UPS™ X
2000/2200/3000 VA Tower/Rack-Mount 4U
Important Safety Messages
Read the instructions carefully to become familiar with the equipment before trying to install, operate,
service or maintain it. The following special messages may appear throughout this manual or on the
equipment to warn of potential hazards or to call attention to information that clarifies or simplifies a
procedure.
The addition of this symbol to a Caution product safety label indicates that a hazard exists that can result in
injury and product damage if the instructions are not followed.
The following safety messages may appear throughout this manual to warn of potential hazards.
Safety and General Information
Read the Safety Guide supplied with this unit before installing the UPS.
• Adhere to all local and national electrical codes.
• This UPS is intended for indoor use only.
• Do not operate this UPS in direct sunlight, in contact with fluids, or where there is excessive dust or
humidity.
• Be sure the air vents on the UPS are not blocked. Allow adequate space for proper ventilation.
• The battery typically lasts for two to five years. Environmental factors impact battery life. Elevated
ambient temperatures, poor quality utility power, and frequent short duration discharges will shorten
battery life.
• Connect the UPS power cable directly to a wall outlet. Do not use surge protectors or extension cords.
• The batteries are heavy. Remove the batteries prior to installing the UPS in a rack.
• Always install external battery packs (XLBPs) at the bottom of the rack. The UPS must be installed
above the XLBPs.
• The UPS display interface will recognize as many as 10 external battery packs connected to the UPS.
However there is no limit to the number of XLBPs that can be used with the UPS.
• Refer to Specifications in the Operation manual for UPS and battery weight.
CAUTION
CAUTION indicates a potentially hazardous situation which, if not avoided, can result in equipment damage and minor or
moderate injury.
CAUTION
CAUTION indicates a potentially hazardous situation which, if not avoided, can result in equipment damage.
Produkt Specifikationer
Mærke: | APC |
Kategori: | Server |
Model: | SMX2200HVNC |
Bredde: | 178 mm |
Dybde: | 483 mm |
Højde: | 432 mm |
Vægt: | 38560 g |
Produktfarve: | Sort |
Batterikapacitet: | 702 At |
Skærmtype: | LED |
Pakkevægt: | 47630 g |
Pakkedybde: | 633 mm |
Pakkebredde: | 586 mm |
Pakkehøjde: | 330 mm |
Batteriteknologi: | Blybatterier (VRLA) |
Formfaktor: | Reolbeslag/tårn |
Responstid: | 10 ms |
Opbevaringstemperatur (T-T): | -15 - 45 °C |
Relativ luftfugtighed ved drift (H-H): | 0 - 95 % |
Relativ luftfugtighed ved opbevaring (H-H): | 0 - 95 % |
Ethernet LAN-porte (RJ-45): | 1 |
Antal USB 2.0-porte: | 1 |
Driftstemperatur (T-T): | 0 - 40 °C |
Hurtig installationsvejledning: | Ja |
Kabler inkluderet: | Input power cable, USB cable |
Støjniveau: | 55 dB |
Udgangseffekt: | 1980 W |
Certificering: | CE, EAC, EN/IEC 62040-1, EN/IEC 62040-2, GS Mark, IRAM, RCM, VDE, WEEE |
Produkter pr. palle: | 6 stk |
Webbaseret administration: | Ja |
LED-indikatorer: | Ja |
Udgangsspænding: | 230 V |
Kabellængde: | 2 m |
Harmoniseret systemkode (HS): | 85078000 |
Opladningstid for batteri: | 3 t |
Bæredygtighedscertifikater: | RoHS |
Driftshøjde: | 0 - 3000 m |
Ikke-drift højde: | 0 - 15000 m |
Indgangsfrekvens: | 50/60 Hz |
Lydalarmer: | Ja |
Strømstik: | C20 forbinder |
Rack monteringskit: | Ja |
AC udgange, antal: | 10 AC stikkontakt(er) |
AC stikkontakt typer: | C13 coupler, C19 coupler, C20 coupler |
Indgående driftsspænding (maks.): | 280 V |
Ressource CD: | Ja |
Rackkapacitet: | 2U |
Output strømkapacitet (VA): | 2.2 kVA |
Indgående driftsspænding (min.): | 140 V |
Udgangs driftsspænding (min.): | 208 V |
Udgangs driftsspænding (maks.): | 240 V |
UPS topologi: | Interaktivt indgangsstik |
Regulering af udgangsfrekvens: | +/- 3 Hz |
Beskyttelse ved overspænding: | Ja |
Bølgeform: | Sine |
Hørbare alarmtilstande: | Erstatningsbatteri |
Automatisk batteritest: | Ja |
Koldstart: | Ja |
Hot-swap batteri: | Ja |
Automatisk genstart: | Ja |
Uddgående frekvens: | 50/60 Hz |
Nødstrøm Off (EPO): | Ja |
EMI/RFI støjfiltrering: | Ja |
Regulering af udgangsspænding: | 5 % |
Har du brug for hjælp?
Hvis du har brug for hjælp til APC SMX2200HVNC stil et spørgsmål nedenfor, og andre brugere vil svare dig
Server APC Manualer
23 April 2024
9 April 2024
22 Januar 2024
10 September 2023
8 Maj 2023
20 April 2023
17 April 2023
13 Marts 2023
10 Januar 2023
4 December 2022
Server Manualer
- Server QNAP
- Server Bosch
- Server Acer
- Server HP
- Server Asus
- Server Gigabyte
- Server Toshiba
- Server Lenovo
- Server Planet
- Server Black Box
- Server TRENDnet
- Server Buffalo
- Server Cisco
- Server Seagate
- Server Netgear
- Server Tripp Lite
- Server Western Digital
- Server Digitus
- Server Dell
- Server Fujitsu
- Server FLIR
- Server ZyXEL
- Server Eaton
- Server ELAC
- Server Synology
- Server Hikvision
- Server Monacor
- Server AVerMedia
- Server Asustor
- Server LaCie
- Server Naim
- Server Teo
- Server Promise Technology
Nyeste Server Manualer
26 Maj 2024
25 Maj 2024
20 Maj 2024
14 Maj 2024
11 Maj 2024
8 Maj 2024
5 Maj 2024
4 Maj 2024
2 Maj 2024
30 April 2024