APPA 62T Manual


Læs gratis den danske manual til APPA 62T (3 sider) i kategorien Multimeter. Denne vejledning er vurderet som hjælpsom af 19 personer og har en gennemsnitlig bedømmelse på 3.5 stjerner ud af 10 anmeldelser. Har du et spørgsmål om APPA 62T, eller vil du spørge andre brugere om produktet?

Side 1/3
<300MM
SELV
>50MM
>35MM
3-10MM
Disable Auto Power Off
NCV
1. Volt sense switch will be activated on any function
or at OFF status.
2. Test leads are not used for the Volt sense test.
3. Press the Volt sense button. The display goes
black, a tone sounds and the red LED lights up to
verify the instrument is operational. The Volt sense
button must be held down to detect the presence
of voltage without use of the leads.
4. If a voltage of 50V to 600V (50 to 500Hz) is
detected near the top of meter a continuous tone
sounds and the red LED near the top of meter
Illuminates.
Fuse Replacement (For 62, 62T, 62R only)
Refer to the following figure to replace fuse :
Battery Replacement
Refer to the following figure to replace the batteries :
Caution
˙ Replace the batteries as soon as the low batteries
indicator "<" appears, to avoid false reading.
˙ Batteries 1.5V x 2
Caution
˙ Use only a fuse with the amperage, interrupt,
voltage, and speed rating specified.
˙ Fuse rating : 10A, 500V
Non-Contact Voltage (Volt sense)
Auto Power Off (Battery Saver)
Manual Ranging and Auto Ranging
10 min
Specifications
General Specifications
Display : 2000 counts.
Polarity Indication : Automatic, positive implied,
negative indicated.
Overrange Indication : “OL” or “-OL”.
Batteries
Life : Alkaline 250 hours
Low Batteries Indication : <” is displayed when
the batteries voltage drops below operating voltage.
Auto Power Off : Approx 10 minutes.
Operating Ambient : Non-condensing
50F,
51.8F ~ 86F (
80% R.H) 87.8F ~ 104F (
75% R.H),
105.8F ~ 122F (
45% R.H)
Storage Temperature : -4F to 140F , 0 to 80%
R.H. when battery removed from Meter.
Temperature Coefficient :
0.15 x (Spec.Accy) / F ,< 64.4F or > 82.4F.
Measure : Samples 2 times per second nominal.
Altitude : 6561.7 ft (2000m)
Safety : Complies with EN61010-1, UL61010-1,
IEC 61010-1,
V/
:
CAT.III. 600V, CAT.II. 1000V.
A : CAT.III. 500V (for 62/62T/62R only)
Pollution degree : 2
Power Requirements :
1.5V x 2 IEC LR03, AM4 or AAA size
Dimensions (W x H x D) : 74mm x 156mm x 44mm
Weight : (320g) including battery.
Accessories : Battery (installed), Test leads and
user manual.
Measuring DC / AC Current
(For 62, 62T, 62R only)
Disconnect
Temperature °C ,°F
R
DCV
Display Hold


Produkt Specifikationer

Mærke: APPA
Kategori: Multimeter
Model: 62T

Har du brug for hjælp?

Hvis du har brug for hjælp til APPA 62T stil et spørgsmål nedenfor, og andre brugere vil svare dig




Multimeter APPA Manualer

APPA

APPA 62 Manual

13 September 2024
APPA

APPA 91 Manual

21 Juli 2024
APPA

APPA 93N Manual

18 Juli 2024
APPA

APPA 607 Manual

6 Juli 2024
APPA

APPA 99 II Manual

4 Juli 2024
APPA

APPA 106 Manual

4 Juli 2024
APPA

APPA 97R Manual

10 December 2023
APPA

APPA 62R Manual

19 Maj 2023
APPA

APPA 71 Manual

7 December 2022
APPA

APPA 73 Manual

12 Oktober 2022

Multimeter Manualer

Nyeste Multimeter Manualer

Brymen

Brymen BM867s Manual

24 Juni 2025
Sanwa

Sanwa CD800a2 Manual

24 Juni 2025
Sanwa

Sanwa CD800a3 Manual

23 Juni 2025
Brymen

Brymen BM829s Manual

22 Juni 2025
Brymen

Brymen BM525s Manual

22 Juni 2025
Draper

Draper 52320 Manual

8 Juni 2025
VOREL

VOREL 81780 Manual

7 Juni 2025
Brymen

Brymen BM878 Manual

7 Juni 2025
Brymen

Brymen BM789 Manual

6 Juni 2025
Draper

Draper 16232 Manual

6 Juni 2025