Læs gratis den danske manual til Broil King Porta-Chef Pro (24 sider) i kategorien Grill. Denne vejledning er vurderet som hjælpsom af 23 personer og har en gennemsnitlig bedømmelse på 4.6 stjerner ud af 12 anmeldelser. Har du et spørgsmål om Broil King Porta-Chef Pro, eller vil du spørge andre brugere om produktet?

Side 1/24
GAS BARBECUES
OWNER'S MANUAL
FOR USE WITH L.P. GAS (LIQUIFIED PETROLEUM GAS)
IN CANADA - PROPANE GAS
DANGER
If you smell gas:
1. Shut off gas to the appliance.
2. Extinguish any open flame.
3. Open lid.
4. If odor continues, keep away from the
appliance and immediately call your gas
supplier or your fire department.
WARNING
1. Do not store or use gasoline or other
flammable liquids or vapors in the vicinity
of this or any other appliance.
2. An LP cylinder not connected for use shall
not be stored in the vicinity of this or any
other appliance.
ANSI Z21.58b-2012 / CSA 1.6b-2012
CONTENTS
SAFETY .............................................................2
INSTALLATION .................................................2
L.P. GAS CYLINDER.........................................3
OPD EQUIPPED CYLINDER.............................4
HOSE & REGULATOR......................................4
LEAK TESTING .................................................5
VENTURI TUBES ..............................................5
LIGHTING ..........................................................6
OPERATION ......................................................7
COOKING TECHNIQUES..................................7
MAINTENANCE...............................................10
TROUBLE SHOOTING....................................11
WARRANTY ....................................................12
Please record your model and
serial number here.
Model number
Serial number
Date of purchase
READ ALL INSTRUCTIONS CAREFULLY BEFORE OPERATING YOUR GAS BARBECUE
RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE
1-800-265-2150
info@omcbbq.com
10094-LP REV L 04/13
SAFETY INSTALLATION
Your new OMC gas grill is a safe, convenient appliance
when assembled and used properly. However, as with all
gas-fired products, certain safeguards must be observed.
Failure to follow these safeguards may result in
damage or injury. If you have questions concerning
assembly or operation, consult your dealer, gas appliance
serviceman, your gas company or our direct customer
service line at 800-265-2150.
CAUTION
FOR OUTDOOR USE ONLY.
IF STORED INDOORS, DETACH AND LEAVE
CYLINDER OUTDOORS.
THIS APPLIANCE MUST NOT BE OPERATED
UNATTENDED.
SPECIAL CARE MUST BE TAKEN TO KEEP
SMALL CHILDREN AWAY FROM HEATED
SURFACES.
2
Use caution when handling or transporting this
product. Metal edges can present a hazard. Use
appropriate gloves when lifting or handling. Before
lifting, remove side shelves and grids and grates.
ELECTRICAL CAUTION
1. If any accessory is used on this appliance that
requires an external electrical power source, the
accessory when installed must be electrically
grounded in accordance with local codes. In the
absence of local codes, the following standards apply:
(U.S.A.) ANSI/NFPA No. 70-Latest Edition
and
(CANADA) CSA C22.1 Canadian Electrical Code
2. Do not cut or remove the grounding prong from the
plug.
3. Keep the electrical supply cord and fuel supply hose
away from any heated surface.
PROPOSITION 65 WARNING
Handling the brass material on this product exposes you to
lead, a chemical known to the state of California to cause
cancer, birth defects or other reproductive harm. WASH
YOUR HANDS AFTER HANDLING THIS PRODUCT.
WARNING
Fuels used in gas or oil-fired appliances, and the products
of combustion of such fuels, contain chemicals known to
the State of California to cause cancer, birth defects or
other reproductive harm.
“This warning is issued pursuant to California Health and
Safety Code Sec. 25249.6
1. In Canada, this appliance must be installed in
accordance with the local code and the relevant
CSA standards:
CSA-B149.1 Natural Gas and Propane installation Code
In the U.S.A., this appliance must be installed in
accordance with the local code and the relevant
national code.
ANSI Z223.1/NFPA 54 - Latest Edition National Fuel Gas
Code and Latest Local Codes where Applicable
2. The appliance must be located away from combustible
surfaces by at least 76cm/30” from each side, and
76cm/30” from the rear.
76cm / 30
76cm / 30
3. Do not operate this appliance under any overhead
roof construction or foliage.
4. This appliance is for OUTDOOR USE ONLY, DO NOT
operate in garage, shed, balcony or other such
enclosed areas.
5. DO NOT restrict the flow of air to the appliance.
6. Keep the area surrounding the appliance free of
combustible materials, gasoline, and all flammable
liquids and vapours.
7. This appliance is not intended to be installed in, or on,
recreational vehicles and/or boats.
8. Keep the ventilation opening(s) of the cylinder
enclosure free and clear from debris.
LP GAS CYLINDER PLACEMENT
9. LP gas cylinders must be installed according to
assembly instructions using retainer provided. Do not
store a spare cylinder under or near this appliance. All
cylinders used must be compatible with supplied
means of cylinder retention.