Side 1/4
AR500FS
Rear Exhaust
to atmosphere
Side Exhaust
to atmosphere
Recirculating
Installation
Top Exhaust
to atmosphere
AR125RC
AR125F
AR125FD
Roof cowl
Flue
1200mm length
Alternative flue connection
1 metre flexible duct with joiners
Flashing
Not Supplied
90º bend
AR125B
AR500RK
AR125WV
Wall vent
(includes 400mm of flue)
600-900 Canopy Installation and Operation Manual
The instructions in this manual are for cooker hood models: CS601S,CS602S, CS902S, CS901S, WRF600, WRF600CS, WRF900CS,
WRG630CW,WRG630CS,WRG930CW,WRG930CS,RCD690S,RCD990S
Safety Warnings
Electrical Connection
Accessories
Cleaning
Part Numbers: Description:
These cooker hoods are domestic appliances which have been manufactured and tested to comply with Australian and New Zealand
Standard AS/NZS 3350.2.31.
These appliance are intended to be used in household and similar applications such as: Staff kitchen areas in shops, ofces and other
working environments; Farm Houses; By clients in hotels, motels and other residential type environments; Bed and breakfast type
environments.
This appliance is not intended for used by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience
and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
Children should be supervised to ensure that they do not play with the appliance.
Ensure the cooker hood is switched off before carrying out maintenance, to avoid any possibility of electric shock.
Grease lters must be removed every four weeks (maximum) for cleaning to reduce the risk of re.
Do not amb’e under the cooker hood.
This cooker hood is not recommended for barbeques.
The exhaust air from the cooker hood must not be discharged into any heating ue, which may carry combustion products from other sources.
Exhaust air must not be discharged into a wall cavity, unless the cavity is designed for the purpose.
There must be adequate ventilation of the room when the cooker hood is used at the same time as appliances burning gas or other fuels.
Always cover lit gas burners with pots or pans when the cooker hood is in use.
Always switch off gas burners before you remove pots or pans.
CAUTION: Accessible parts may become hot when used with cooking appliance.
Regulations concerning the discharge of air have to be fullled.
Check that the mains voltage matches with the voltage on the data plate inside the cooker hood.
Check that the installation complies with standards of local gas and electricity authorities.
If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similarly qualied person in order to avoid a hazard.
Use 125mm round exhaust ducting for best performance.
When using exible duct always install duct with the wire helix pulled taut to minimise pressure loss.
Try to keep exhaust duct short and straight.
Keep bends in the exhaust duct to a minimum.
Do not reduce the size or restrict exhaust duct.
Wipe the cooker hood body and ue with a sponge or soft cloth soaked in warm soapy water. Do not use oven cleaners or other abrasive materials.
AR125RC
AR125B
AR125F
AR125FD
AR125VW
AR500FS
AR500RK
AR500CF
Roof Cowl
90º Bend
Flue 1200mm Long
Flexible Duct - 1 Metre Long When Expanded
Wall Vent Kit
Extra Length Flue Cover 1100mm Length Brushed Stainless Steel
Recirculating Kit
Replacement Carbon Filters
DUCTING ACCESSORIES
INSTALLATION OPTIONS
Page 1


Produkt Specifikationer

Mærke: Chef
Kategori: Emhætte
Model: CS902S

Har du brug for hjælp?

Hvis du har brug for hjælp til Chef CS902S stil et spørgsmål nedenfor, og andre brugere vil svare dig




Emhætte Chef Manualer

Chef

Chef RRE934W Manual

5 September 2025
Chef

Chef CG920FGS Manual

5 September 2025
Chef

Chef RFD602S Manual

5 September 2025
Chef

Chef RRE634S Manual

5 September 2025
Chef

Chef CRF610WA Manual

4 September 2025
Chef

Chef CRF610SA Manual

4 September 2025
Chef

Chef CG950CGS Manual

4 September 2025
Chef

Chef CRI514DB Manual

4 September 2025
Chef

Chef REHR6S Manual

4 September 2024
Chef

Chef RRE635W Manual

4 September 2024

Emhætte Manualer

Nyeste Emhætte Manualer

Faber

Faber LINE36ST Manual

2 November 2025
Witt

Witt WVL 60 B Manual

2 November 2025
Faber

Faber INSM21GR240 Manual

2 November 2025
Faber

Faber CRIS36SS400 Manual

2 November 2025
Faber

Faber CHLO28GR600 Manual

2 November 2025
Faber

Faber OSTR36SS400 Manual

2 November 2025
Faber

Faber STRTIS48WHNB Manual

1 November 2025
Witt

Witt Elevate 90 Manual

1 November 2025
Witt

Witt Think 90 W Manual

1 November 2025
Faber

Faber INLT28SSV Manual

1 November 2025