Læs gratis den danske manual til Dimplex DPRC26ECO-A (24 sider) i kategorien Klimaanlæg. Denne vejledning er vurderet som hjælpsom af 35 personer og har en gennemsnitlig bedømmelse på 4.5 stjerner ud af 18 anmeldelser. Har du et spørgsmål om Dimplex DPRC26ECO-A, eller vil du spørge andre brugere om produktet?

Side 1/24
Portable Air Conditioner
Model: DPRC26ECO-A
For domestic household use only.
INSTRUCTION MANUAL
2
Please read the operating instructions carefully before using your Portable Air
Conditioner for the first time and keep them in a safe place.
WARNING This appliance must not be used in a bathroom.
WARNING Do not use this appliance in the immediate surroundings of a bath,
a shower or a swimming pool.
If the mains lead is damaged it must only be replaced by the manufacturers
service agent or a similarly qualified person in order to avoid a hazard.
This appliance is not intended for use by persons (including children) with
reduced physical, sensory or mental capabilities, or lack of experience
and knowledge, unless they have been given supervision or instruction
concerning use of the appliance by a person responsible for their safety.
Children should be supervised to ensure they do not play with the appliance.
Prior to cleaning or other maintenance, the appliance must be disconnected
from the supply mains.
Never immerse the appliance in water or other liquids.
Operate this unit only on a firm, flat surface to avoid the risk of water
leakage. Ensure that the unit is kept upright at all times.
Do not place on soft, unstable or non-horizontal/angled surfaces.
Never operate the appliance if a cable or connector has been damaged,
after appliance malfunction or if the appliance was dropped or is otherwise
damaged.
Please ask a professional service agent to repair the product. Improper repair
may cause danger to users.
Disconnect the appliance from mains power whenever it is not in use, before
relocating it, and before cleaning.
Operate the appliance only at the voltage specified on the rating label.
Only connect the unit to a properly installed and easily accessible socket so
that you can quickly disconnect the plug if necessary.
Do not connect this product to the mains using an extension lead.
This product is only intended for applications. INDOOR RESIDENTIAL
This product should not be used for commercial or industrial or leisure
applications or in small enclosed spaces.
Never use the mains lead as a carrying strap or pulling lead.
CAUTION: FAILURE TO FOLLOW THESE INSTRUCTIONS MAY CAUSE
INJURY AND/OR DAMAGE AND MAY INVALIDATE YOUR WARRANTY
IMPORTANT
THESE INSTRUCTIONS SHOULD BE READ CAREFULLY AND
RETAINED FOR FUTURE REFERENCE.
Note also the information presented on the appliance
5
1. Transport of equipment containing flammable refrigerants - see transport
regulations
2. Marking of equipment using signs - see local regulations
3. Disposal of equipment using flammable refrigerants - see national regulations.
4. Storage of equipment/appliances - The storage of equipment should be in
accordance with the manufacturer’s instructions.
5. Storage of packed (unsold) equipment - storage package protection should be
constructed such that mechanical damage to the equipment inside the package
will not cause a leak of the refrigerant charge. The maximum number of pieces of
equipment permitted to be stored together will be determined by local regulations.
6. Information on servicing
Checks to the area
Prior to beginning work on systems containing flammable refrigerants, safety
checks are necessary to ensure that the risk of ignition is minimised. For repair to
the refrigerating system, the following precautions shall be complied with prior to
conducting work on the system.
Work procedure
Work shall be undertaken under a controlled procedure so as to minimise the risk of
a flammable gas or vapour being present while the work is being performed.
General work area
All maintenance staff and others working in the local area shall be instructed on the
nature of work being carried out. Work in confined spaces shall be avoided. The
area around the workspace shall be sectioned off. Ensure that the conditions within
the area have been made safe by control of flammable material.
Checking for presence of refrigerant
The area shall be checked with an appropriate refrigerant detector prior to
and during work, to ensure the technician is aware of potentially flammable
atmospheres. Ensure that the leak detection equipment being used is suitable for
use with flammable refrigerants, i.e. non-sparking, adequately sealed or intrinsically
safe.
Presence of fire extinguisher
If any hot work is to be conducted on the refrigeration equipment or any associated
parts, appropriate fire extinguishing equipment shall be available to hand. Have a
dry powder or CO2 fire extinguisher adjacent to the charging area.
No ignition sources
No person carrying out work in relation to a refrigeration system which involves
exposing any pipe work that contains or has contained flammable refrigerant shall
use any sources of ignition in such a manner that it may lead to the risk of fire or
explosion. All possible ignition sources, including cigarette smoking, should be kept
sufficiently far away from the site of installation, repairing, removing and disposal,
during which flammable refrigerant can possibly be released to the surrounding
space. Prior to work taking place, the area around the equipment is to be surveyed
to make sure that there are no flammable hazards or ignition risks. No Smoking
signs shall be displayed.
Ventilated area
Ensure that the area is in the open or that it is adequately ventilated before
breaking into the system or conducting any hot work. A degree of ventilation shall
continue during the period that the work is carried out. The ventilation should
safely disperse any released refrigerant and preferably expel it externally into the
atmosphere.
9
Recovery
When removing refrigerant from a system, either for servicing or decommissioning,
it is recommended good practice that all refrigerants are removed safely. When
transferring refrigerant into cylinders, ensure that only appropriate refrigerant
recovery cylinders are employed. Ensure that the correct number of cylinders
for holding the total system charge is available. All cylinders to be used are
designated for the recovered refrigerant and labelled for that refrigerant (i.e.
special cylinders for the recovery of refrigerant). Cylinders shall be complete with
pressure relief valve and associated shut-off valves in good working order. Empty
recovery cylinders are evacuated and, if possible, cooled before recovery occurs.
The recovery equipment shall be in good working order with a set of instructions
concerning the equipment that is at hand and shall be suitable for the recovery
of flammable refrigerants. In addition, a set of calibrated weighing scales shall
be available and in good working order. Hoses shall be complete with leak-free
disconnect couplings and in good condition. Before using the recovery machine,
check that it is in satisfactory working order, has been properly maintained and
that any associated electrical components are sealed to prevent ignition in the
event of a refrigerant release. Consult manufacturer if in doubt. The recovered
refrigerant shall be returned to the refrigerant supplier in the correct recovery
cylinder, and the relevant Waste Transfer Note arranged. Do not mix refrigerants
in recovery units and especially not in cylinders. If compressors or compressor oils
are to be removed, ensure that they have been evacuated to an acceptable level
to make certain that flammable refrigerant does not remain within the lubricant.
The evacuation process shall be carried out prior to returning the compressor to
the suppliers. Only electric heating to the compressor body shall be employed to
accelerate this process. When oil is drained from a system, it shall be carried out
safely.
11
Parts
1. Control panel
2. Air outlet with adjustable louvre
3. Handle
4. Air inlet with air filter
5. Caster
6. Drainage Hole
7. Air Exhaust
2
34
5
6
7
Note: The appearance is only for reference. Please see the real product
for detailed information.
1
UNPACKING
Unpack the carton and take the appliance and accessories out.
Check the device after unpacking for any damage or scratches on it.
Accessories:
1. Exhaust hose
2. Hose connector
3. Window kit adapter
4. Remote control
5. Drainage hose
6. Swing window kit
1 432
High
Low
Timer Power
Sleep
Heat Fan
Down
Up Cool
Dry
C/ F
5 6
Window Seal
Velcro Tape


Produkt Specifikationer

Mærke: Dimplex
Kategori: Klimaanlæg
Model: DPRC26ECO-A

Har du brug for hjælp?

Hvis du har brug for hjælp til Dimplex DPRC26ECO-A stil et spørgsmål nedenfor, og andre brugere vil svare dig




Klimaanlæg Dimplex Manualer

Klimaanlæg Manualer

Nyeste Klimaanlæg Manualer