Dimplex RXPW1 Manual


Læs nedenfor 📖 manual på dansk for Dimplex RXPW1 (2 sider) i kategorien Ikke kategoriseret. Denne guide var nyttig for 21 personer og blev bedømt med 4.5 stjerner i gennemsnit af 2 brugere

Side 1/2
Installation and Operating Instructions
TIDN7DP001 Issue 0
RXPW1 - 7 Day Timer/Programmer
IMPORTANT: THESE INSTRUCTIONS SHOULD BE READ CAREFULLY AND RETAINED FOR FUTURE REFERENCE
MODE PROG ENTER
12:13
MAN OFF
M
T
W
T
F
S
S
Fig. 1
General
The RXPW1 can only be used
in the PLX05 electronic range
of heaters.
They offer either individual
programming (each individual
heater has a programming
module) or group programming
from a master heater through
the pilot wire. Group
programming can drive up to
10 slave heaters.
Two heating positions are offered: comfort and off, with
temperatures set using the controls on the heater.
For default Screen see Fig. 1.
Installation
The RXPW1 is rated at 230V.
1. Switch the heater off.
2. Using a narrow bladed screwdriver, carefully release
the cover from the slot on right hand side of the
thermostat on the Panel Heater.
3. Remove the 7-day plug in timer from it’s box and plug
it into the slide in compartment now exposed - see Fig.
2 . Insert the programmer fully so that it clicks into
position. Switch the heater back on at the mains supply.
Individual Programming
Fit one programmer to each EPX heater. (Note: When the
heater is installed, the black pilot wire in the mains supply
cable should be trimmed back in accordance with the
Installation Instructions.
Programming for a Zone
The heater containing the RXPW1 is the Master heater and
connected by the black pilot wire to the Slave heaters. The
Master heater determines the Program and heating levels for
all the heaters (Comfort and Off), but the actual comfort
temperature should still be set on each individual heater (see
EPX Panel Heater instructions). The master heater will switch
between Comfort and Off according to the program.
Electrical Connection Master/Slave Heaters
DO NOT connect the BLACK (PILOT) SIGNAL WIRE to earth.
When the programmer drives other heaters, connect the pilot
wire from the ‘MASTER’ unit to the pilot wire of a ‘SLAVE’
heater and then from one ‘SLAVE’ heater to another (in series)
- see Fig. 3.
LEN
Fig. 2
LEN
MASTER SLAVE SLAVE
PIL OT WIRE
UP TO
10 UN ITS
Fig. 3
Any 240V insulated cable may be used to link pilot wires
around the ring main. The signal current is low. Suitable
connections would be either an additional single core wire
marked or colour coded appropriately or use a 4 core cable
throughout the heater ring.
Operating Instructions
The RXPW1 can be programmed either inserted directly into
the heater or out of the heater. If choosing the latter option,
the cassette must be first left in the heater for 2 days to charge
the battery. Remember that the battery only lasts for 24 hours.
Problem Solving
In the event that no display appears on your 7-day timer do
the following :
1. Press any button to reactivate the display. Failing this -
2. Return to the heater to charge battery (internal battery lasts
for 24 hours when timer is removed from heater). Display will
appear immediately but battery will be fully charged in 2 days.
Mode Selection
There are three different
operating modes. Press MODE
to cycle through these:
MAN OFF - heating is
permanently Off – see Fig. 4.
This is also the default screen.
MAN ON - heating is
permanently On - see Fig. 5.
AUTO - runs the programmed
times - see Fig. 6.
MODE PROG ENTER
12:13
MAN OFF
M
T
W
T
F
S
S
Fig. 4
MODE PROG ENTER
00:00
MAN ON
M
T
W
T
F
S
S
Fig. 5
MODE PROG ENTER
00:00
AUTO ON
M
T
W
T
F
S
S
Fig. 6


Produkt Specifikationer

Mærke: Dimplex
Kategori: Ikke kategoriseret
Model: RXPW1

Har du brug for hjælp?

Hvis du har brug for hjælp til Dimplex RXPW1 stil et spørgsmål nedenfor, og andre brugere vil svare dig




Ikke kategoriseret Dimplex Manualer

Ikke kategoriseret Manualer

Nyeste Ikke kategoriseret Manualer