Læs gratis den danske manual til Dimplex WFC3NS (4 sider) i kategorien Ikke kategoriseret. Denne vejledning er vurderet som hjælpsom af 34 personer og har en gennemsnitlig bedømmelse på 4.6 stjerner ud af 17.5 anmeldelser. Har du et spørgsmål om Dimplex WFC3NS, eller vil du spørge andre brugere om produktet?

Side 1/4
Installation and Operating Instructions
Dimplex Wall-mounted Fan Convector 08/18724/0 Issue 0
Models : WFC 3NB and WFC 3NS
350mm min
571mm 120mm
350mm
Dimensions
Model(s) Specification
WFC 3NB 3kW, Switch, Thermostat & Neon - Black
WFC 3NS 3kW, Switch, Thermostat & Neon - Silver
Fig. 1
Installation
Before undertaking installation work, ensure the electricity supply
is disconnected from any relevant fixed wiring.
Supply cable is not provided with this appliance, and a competent
electrician should therefore install it.
The appliance must be fitted horizontally with the cable or conduit entry
at bottom right. It should be mounted such that the underside is at least
350mm above the floor and the top of the heater is 150mm below any
overhanging shelf or obstruction.
This heater must be used on an A.C.~ supply only and the voltage
marked on the heater must correspond to the supply voltage.
To comply with the I.E.E. Wiring Regulations, the appliance must be
earthed; the supply circuit must be adequate for the input of the
appliance, and the circuit protected by a suitable 13A fuse. A suitable
termination to the fixed wiring of the premises must be provided adjacent
to the final position of the appliance. In this instance, such a termination
can be a double-pole switch with a contact separation of at least 3mm in
all poles.
The heater must not be located immediately below a socket-outlet.
Electrical
WARNING : THIS APPLIANCE MUST BE EARTHED.
After ensuring the electricity supply is not live, electrical connections can
be made, either to an adjacent double-pole switch having a contact
separation of at least 3mm in all poles or to a plug-top for use in a
standard 13A socket.
If the latter: Connect Green and Yellow wire to plug terminal marked E
or Green
or Green and Yellow
. Connect Blue wire to plug terminal
marked N or Black. Connect Brown wire to plug terminal marked L or
Red.
Refit cover, first hooking top over the back of the unit and then securing
the bottom by refitting the two screws under the bottom edge. The
appliance is now ready for use and the electricity supply can be
reinstated.
THESE INSTRUCTIONS SHOULD BE READ CAREFULLY AND RETAINED FOR FUTURE REFERENCE.
IMPORTANT SAFETY ADVICE
WARNING – THIS APPLIANCE MUST NOT BE USED IN A
BATHROOM.
WARNING DO NOT USE THIS HEATER IN THE IMMEDIATE
SURROUNDINGS OF A BATH, A SHOWER OR A SWIMMING
POOL.
WARNING THIS HEATER MUST NOT BE LOCATED
IMMEDIATELY BELOW A FIXED SOCKET OUTLET.
DO NOT USE THE HEATER UNTIL IT IS WALL MOUNTED
CORRECTLY.
The heater carries a warning 'Do Not Cover' to alert the user
to the risk of overheating that exists if the heater is
accidentally covered.
NEVER cover or obstruct in any way the air inlet slots at the
front of the heater or the heat outlet slots in the base of the
heater.
Keep combustible materials such as drapes and other
furnishings clear from the front of the heater. Do not use
heater to dry your laundry.
If young children, the aged, or infirm are likely to be left in
the vicinity of the heater, we advise that adequate
precautions should be taken. We recommend that a guard
be fitted to ensure contact with the heater is avoided and
objects cannot be inserted into the product.
If you use this heater in conjunction with a thermal control, a
programme controller, a timer or any other device which
switches on the heater automatically, remember to observe
all safety warnings at all times.
Do not use where excessive dust or moisture is present.
For further information, please contact our guard supplier
direct on Tel. No. 01603 667957, or in the case of difficulty or
for further advice contact the Customer Helpline.
Operation
Fixing dimensions
cable or
conduit entry
35mm
510mm
571mm
f
280
Ø10m
shel
150mm min
350mm min.
8mm
350mm
mm
m
6mm
Fig. 2 - Controls &
Control Panel Layout
Fig. 3
Procedure
The Dimplex WFC 3NB and WFC 3NS have a total loading of 3 kW.
They are fitted with two control knobs and a pilot light. The air inlet is in
the front panel, and the outlet on the underside.
Release the front cover from the unit by undoing the two screws under the
bottom edge. The upper knob operates a six-position switch, giving a choice of
operating characteristics as follows :
Carefully remove cover by pulling bottom-front forward, and then lift to
release top from retaining slots.
Off
Mark screw fixing positions on wall in accordance with the dimensions
shown on the diagram. The unit must be secured to the wall with four
screws through the holes provided. The two upper holes are keyhole
shaped to enable the two upper screws to be positioned first. The unit can
then be hung on these screws while the two lower screws are positioned.
Before finally tightening all four screws, ensure the unit is truly horizontal.
. 1kW of heat, low fan speed
2kW of heat, medium fan speed.
3kW of heat, high fan speed.
Fit a 3 core 1.5 square millimetre flexible cord through the cable entry
bush, connect wires to the appropriate terminals and tighten cable clamp.
Alternatively the heater may be connected with conduit through the base
after removing the knockout containing the cable entry bush (see Fig. 4
Wiring Diagram).
Fan only, low speed.
.Fan only, high speed
The lower knob operates a thermostat which enables the temperature of
the room to be regulated.
Wiring Diagram
The pilot light indicates when the appliance is connected to the electricity
supply.
Component Wire
A. Cross flow fan 1. White 1mm
2 Additionally, a cut-out is incorporated in the unit which will switch the
electricity supply off if for any reason the appliance overheats.
B. Cut –out 2. Pink 1mm
2
C. Selector switch 3. Violet 1mm
2 If the cut-out has operated because the air flow has been obstructed in
some way, the heater will switch on once the obstruction has been
removed. If the cut-out continues to operate intermittently the heater
should be switched off and a service agent should be called.
D. Neon light 4. Brown 1mm2
E. Thermostat 5. Red 1mm
2
F. Resistor 6,7. Blue 1.5mm2
G. Earth Terminal 8,9. Red 1.5mm
2
H. Terminal Block 10. Grey 0.75mm
2 To control the room temperature, set the mark on the thermostat knob to
the required temperature on the visually graduated scale (see Fig. 2).
The thermostat will monitor continuously the temperature of the air
returning to the inlet grille, and the appropriate heater element(s) will be
selected automatically to achieve or maintain the chosen level efficiently
and economically.
J. Cable Clamp
Fig. 4


Produkt Specifikationer

Mærke: Dimplex
Kategori: Ikke kategoriseret
Model: WFC3NS

Har du brug for hjælp?

Hvis du har brug for hjælp til Dimplex WFC3NS stil et spørgsmål nedenfor, og andre brugere vil svare dig




Ikke kategoriseret Dimplex Manualer

Dimplex

Dimplex QRAD200E Manual

12 Januar 2025
Dimplex

Dimplex CFH90 Manual

5 Oktober 2024
Dimplex

Dimplex OCR20Tie Manual

1 Oktober 2024
Dimplex

Dimplex OPH13 Manual

29 September 2024
Dimplex

Dimplex GLN20BR Manual

18 September 2024
Dimplex

Dimplex SRX120EM Manual

17 September 2024
Dimplex

Dimplex CAB10ER Manual

12 September 2024
Dimplex

Dimplex RFM Manual

6 September 2024
Dimplex

Dimplex CAS400NH Manual

31 August 2024

Ikke kategoriseret Manualer

Nyeste Ikke kategoriseret Manualer