Extech MO210 Manual


Læs gratis den danske manual til Extech MO210 (6 sider) i kategorien Måleudstyr. Denne vejledning er vurderet som hjælpsom af 8 personer og har en gennemsnitlig bedømmelse på 4.6 stjerner ud af 4.5 anmeldelser. Har du et spørgsmål om Extech MO210, eller vil du spørge andre brugere om produktet?

Side 1/6
USERGUIDE
Moisture Meter
Model MO210
MO210-EU-EN V2.1 8/12
2
Introduction
Thank you for selecting the Extech Model MO210. This device is shipped fully tested and calibrated
and, with proper use, will provide years of reliabl website (www.extech.com) e service. Please visit our
to check for the latest version of this User Guide, Product Updates, and Customer Support.
Safety
International Safety Symbols
This symbol, adjacent to another symbol or terminal, indicates the user must refer to the
manual for further information.
This symbol, adjacent to a terminal, indicates that, under normal use, hazardous voltages
may be present
Double insulation
Safety Notes
Do not exceed the maximum allowable input range of any function.
Set the function switch OFF when the device is not in use.
Remove the battery if the device is to be stored for longer than 60 days.
Never dispose of batteries in a fire. Batteries may explode or leak.
Never mix battery types. Always install new batteries of the same type.
Warnings
Set function switch to the appropriate position before measuring.
Do not measure current on a circuit whose voltage exceeds 600V.
When changing ranges always om the circuit under test. disconnect the test leads fr
Cautions
Improper use of this meter can cause damage, shock, injury or death. Read and understand
this user manual before operating the meter.
Always remove the test leads before replacing the battery.
Inspect the condition of the test leads and the meter itself for any damage before operating the
meter. Repair or replace any damage before use.
Use great care when making measurements if the voltages are greater than 25VAC rms or
35VDC. These voltages are considered a shock hazard.
Voltage checks on electrical outlets can be difficult and misleading because of the uncertainty
of connection to the recessed electrical contacts. Other means should be used to ensure that
the terminals are not "live".
If the equipment is used in a manner not specified by the manufacturer, the protection provided
by the equipment may be impaired.


Produkt Specifikationer

Mærke: Extech
Kategori: Måleudstyr
Model: MO210

Har du brug for hjælp?

Hvis du har brug for hjælp til Extech MO210 stil et spørgsmål nedenfor, og andre brugere vil svare dig




Måleudstyr Extech Manualer

Extech

Extech CO15 Manual

30 Januar 2025
Extech

Extech PRC20 Manual

5 September 2024
Extech

Extech PRC30 Manual

5 September 2024
Extech

Extech SD900 Manual

5 September 2024
Extech

Extech PRC15 Manual

5 September 2024
Extech

Extech 412300A Manual

5 September 2024
Extech

Extech 412400 Manual

5 September 2024
Extech

Extech 433201A Manual

5 September 2024
Extech

Extech SD910 Manual

5 September 2024
Extech

Extech 407119 Manual

2 September 2024

Måleudstyr Manualer

Nyeste Måleudstyr Manualer

Uni-T

Uni-T UT220 Manual

3 April 2025
Uni-T

Uni-T UT681C Manual

3 April 2025
Uni-T

Uni-T UT216C Manual

3 April 2025
Uni-T

Uni-T UT611 Manual

3 April 2025
Uni-T

Uni-T UT210D Manual

3 April 2025
Uni-T

Uni-T UT210C Manual

3 April 2025
Uni-T

Uni-T UT210B Manual

3 April 2025
Uni-T

Uni-T UT682 Manual

3 April 2025
Uni-T

Uni-T UT275 Manual

3 April 2025
Uni-T

Uni-T UT08A Manual

3 April 2025