Faber Agio 36BK Manual

Faber Emhætte Agio 36BK

Læs gratis den danske manual til Faber Agio 36BK (13 sider) i kategorien Emhætte. Denne vejledning er vurderet som hjælpsom af 30 personer og har en gennemsnitlig bedømmelse på 3.9 stjerner ud af 15.5 anmeldelser. Har du et spørgsmål om Faber Agio 36BK, eller vil du spørge andre brugere om produktet?

Side 1/13
Version 7/11 - Page 1
READ THESE INSTRUCTIONS BEFORE YOU START INSTALLING THIS RANGEHOOD
WARNING: - TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE: a) Never leave surface units unattended at high
settings. Boilovers cause smoking and greasy spillovers that may ignite. Heat oils slowly on low or medium setting. b)
-







-

published by NFPA.
ALL WALL AND FLOOR OPENINGS WHERE THE RANGEHOOD IS INSTALLED MUST BE SEALED.
This rangehood requires at least 24" of clearance between the bottom of the rangehood and the cooking surface or countertop.
This minimum clearance may be higher depending on local building code. For example, for gas ranges, a minimum of 30" may
be required. The maximum depth of overhead cabinets is 13". Overhead cabinets on both sides of this unit must be a minimum
of 18" above the cooking surface or countertop. Consult the cooktop or range installation instructions given by the manufacturer
before making any cutouts. MOBILE HOME INSTALLATION The installation of this rangehood must conform to the Manufactured
Home Construction and Safety Standards, Title 24 CFR, Part 3280 (formerly Federal Standard for Mobile Home Construction and
Safety, Title 24, HUD, Part 280).


un élément de la table de cuisson fonctionner sans surveillance à la puissance de chauffage maximale; un renversement/













TOUTE OUVERTURE DANS LE MUR OU LE PLANCHER À PROXIMITÉ DE LA HOTTE DOIT ÊTRE SCELLÉ
Gardez 24 po. de hauteur entre le bas de la hotte et la surface de cuisson. Cette hauteur minimum peut être plus haute suivant le
code municipal. Par exemple, les cuisinières à gaz peuvent requérir 30 po. de hauteur. Les armoires au-dessus ne dépasseront
pas 13 po. de profondeur. Les armoires au-dessus de chaque côté devront être au moins à 18 po. au-dessus de la surface
de cuisson. Consultez la che technique avant de découper les armoires. L'installation de cette hotte doit être conforme aux
Réglements de Manufactured Home Construction and Safety Standards, titre 24 CFR, Section 3280 (anciennement Federal
Standard for Mobile Home Construction and Safety Standards, titre 24 CFR, Section 3280 (anciennement Federal Standard for
Mobile Home Construction and Safety, titre 24, HUD, Section 280).
AGIO
Under Cabinet Tiltout Rangehood
• Installation Instructions
• Use and Care Information

The Installer must leave these instructions with the homeowner.
The homeowner must keep these instructions for future refer-
ence and for local electrical inspectors' use.
Version 7/11 - Page 2

Determine which venting method is best for your application.
Ductwork can extend either through the wall or the roof.
The length of the ductwork and the number of elbows should
be kept to a minimum to provide efcient performance. The
size of the ductwork should be uniform. Do not install two
elbows together. Use duct tape to seal all joints in the ductwork
system. Use caulking to seal exterior wall or oor opening
around the cap.
Flexible ductwork is not recommended. Flexible ductwork
creates back pressure and air turbulence that greatly
reduces performance.
Make sure there is proper clearance within the wall or oor
for exhaust duct before making cutouts. Do not cut a joist or
stud unless absolutely necessary. If a joist or stud must be
cut, then a supporting frame must be constructed.
FOR MORE SPECIFIC DUCTWORK INFORMATION, GO
TO PAGE 4.

Ductwork.

A 120 volt, 60 Hz AC-only electrical supply is required on a separate
15 amp fused circuit. A time-delay fuse or circuit breaker is recom-
mended. The fuse must be sized per local codes in accordance with
the electrical rating of this unit as specied on the serial/rating plate
located inside the unit near the eld wiring compartment. THIS UNIT
MUST BE CONNECTED WITH COPPER WIRE ONLY. Wire sizes
must conform to the requirements of the National Electrical Code,
ANSI/NFPA 70 - latest edition, and all local codes and ordinances.
Wire size and connections must conform with the rating of the appli-
ance. Copies of the standard listed above may be obtained from:
National Fire Protection Association
Batterymarch Park
Quincy, Massachusetts 02269
• Venting system MUST terminate outside
the home.
• DO NOT terminate the ductwork in an attic
or other enclosed space.
• DO NOT use 4" laundry-type wall caps.
• Flexible-type ductwork is not
recommended.
• DO NOT obstruct the ow of combustion
and ventilation air.
• Failure to follow venting requirements may
result in a re.
This appliance should be connected directly to the fused
disconnect (or circuit breaker) through exible, armored or
nonmetallic sheathed copper cable. Allow some slack in the
cable so the appliance can be moved if servicing is ever nec-
essary. A UL Listed, 1/2" conduit connector must be provided
at each end of the power supply cable (at the appliance and
at the junction box).
When making the electrical connection, cut a 1 1/4" hole
in the wall. A hole cut through wood must be sanded until
smooth. A hole through metal must have a grommet.
WARNING - TO REDUCE THE RISK OF FIRE OR ELECTRIC

control device.
-

FOLLOWING: Use this unit only in the manner intended

the manufacturer.
     
service panel and lock the service disconnecting means
to prevent power from being switched on accidentally.



        


-

FOLLOWING: Installation Work And Electrical Wiring Must


Construction.
       

burning equipment to prevent backdrafting. Follow the

standards such as those published by the National Fire



-
age electrical wiring and other hidden utilities.
Ducted fans must always be vented to the outdoors.
WARNING
• Electrical ground is required on this rangehood.
• If cold water pipe is interrupted by plastic,
nonmetallic gaskets or other materials, DO NOT
use for grounding.
• DO NOT ground to a gas pipe.
• DO NOT have a fuse in the neutral or grounding
circuit. A fuse in the neutral or grounding circuit
could result in electrical shock.
• Check with a qualied electrician if you are in doubt
as to whether the rangehood is properly grounded.
• Failure to follow electrical requirements may result
in a re.
WARNING
For residential use only.
!
!
Cold Weather installations
An additional back draft damper should be installed to minimize
backward cold air ow and a nonmetallic thermal break should
be installed to minimize conduction of outside temperatures
as part of the vent system. The damper should be on the cold
air side of the thermal break. The break should be as close as
possible to where the vent system enters the heated portion
of the house.


Produkt Specifikationer

Mærke: Faber
Kategori: Emhætte
Model: Agio 36BK

Har du brug for hjælp?

Hvis du har brug for hjælp til Faber Agio 36BK stil et spørgsmål nedenfor, og andre brugere vil svare dig