Læs gratis den danske manual til Fluke i2000 Flex (10 sider) i kategorien Ikke kategoriseret. Denne vejledning er vurderet som hjælpsom af 14 personer og har en gennemsnitlig bedømmelse på 4.7 stjerner ud af 7.5 anmeldelser. Har du et spørgsmål om Fluke i2000 Flex, eller vil du spørge andre brugere om produktet?

Side 1/10
i3000s/i2000 Flex
AC Current Probe
Instructions
Introduction
The i3000s 24 Flex, i3000s 36 Flex, and i2000 Flex AC Current Probes
(the Probe) are used with oscilloscopes, digital multimeters, recorders
or data loggers. The i3000s probes can be used to measure AC current
up to 3000 A. The i2000 can be used to measure AC current up to
2000 A. The flexible measuring head allows current measurements on
conductors that are hard to reach or inaccessible using typical clamp-
on current probes.
The Probes provide a low-voltage (3 V ac for i3000s models, and 2 V ac
for i2000) output that is proportional to the current being measured.
The Probes provide full-scale direct readings for 30 A, 300 A, and
3000 A when using the i3000s models, and 20 A, 200 A, and 2000 A
when using the i2000.
Safety Information
A Warning identifies hazardous conditions and procedures that are
dangerous to the user. A Caution identifies conditions and procedures
that can cause damage to the Product or the equipment under test.
XW Warning
To prevent possible electrical shock, fire, or personal injury:
Read all safety information before you use the Product.
Carefully read all instructions.
Do not alter the Product and use only as specified, or the
protection supplied by the Product can be compromised.
Do not use the Product if it operates incorrectly.
Do not use the Product if it is altered or damaged.
PN 2560447 (English)
March 2006 Rev. 3, 02/22
©2021-2022 Fluke Corporation. All rights reserved. Specifications are
subject to change without notice. All Product names are trademarks of their
respective companies.
2
Have an approved technician repair the Product.
If the Probes are used in a manner not specified in these
operating instructions, protection provided by the Probes
may be impaired.
Use the Probes only if qualified.
Use caution during installation and use of the Probe; high
voltages and currents may be present in circuit under test.
Protect the probe against water and humidity.
Wear protective clothing and gloves as required.
Do not install this product on live conductors. Always de-
energize the circuit under test before installing the flexible
measuring head.
Always inspect the electronics unit, connecting cable, and
flexible measuring head for damage before using the
Probe.
Do not use the Probe if damaged.
Always connect Probe to display device before installing
the flexible measuring head.
Never change batteries while measurement head is
installed on conductor.
Use only the provided original or specified accessories.
Comply with local and national safety codes. Use personal
protective equipment (approved rubber gloves, face
protection, and flame-resistant clothes) to prevent shock
and arc blast injury where hazardous live conductors are
exposed.
CAT III equipment is designed to protect against the
transients in the equipment in fixed equipment
installations, such as distribution panels, feeders and short
branch circuits, and the lighting systems in large buildings.


Produkt Specifikationer

Mærke: Fluke
Kategori: Ikke kategoriseret
Model: i2000 Flex

Har du brug for hjælp?

Hvis du har brug for hjælp til Fluke i2000 Flex stil et spørgsmål nedenfor, og andre brugere vil svare dig




Ikke kategoriseret Fluke Manualer

Fluke

Fluke 1555 Manual

18 Juni 2025
Fluke

Fluke SB140 Manual

14 Juni 2025
Fluke

Fluke Pro3000 Manual

11 Marts 2025
Fluke

Fluke 438-II Manual

8 Oktober 2024
Fluke

Fluke 1670 Manual

8 Oktober 2024
Fluke

Fluke ii905 Manual

8 Oktober 2024
Fluke

Fluke ii915 Manual

8 Oktober 2024
Fluke

Fluke ii500 Manual

7 Oktober 2024
Fluke

Fluke T5-1000 Manual

4 Oktober 2024

Ikke kategoriseret Manualer

Nyeste Ikke kategoriseret Manualer