Fluke i410 Manual


Læs gratis den danske manual til Fluke i410 (10 sider) i kategorien Ikke kategoriseret. Denne vejledning er vurderet som hjælpsom af 12 personer og har en gennemsnitlig bedømmelse på 4.5 stjerner ud af 6.5 anmeldelser. Har du et spørgsmål om Fluke i410, eller vil du spørge andre brugere om produktet?

Side 1/10
PN 642733 December, 1996 1996 Fluke Corporation. All rights reserved. Printed in U.S.A. Product names are trademarks of their respective companies.
i410/i1010
AC/DC Current Clamp
Service Information
WWarning
To avoid electric shock:
Do not service this Current Clamp unless you are qualified to do so.
The service information provided in this document is for use by quali-
fied personnel only.
Always remove input signals from the Current Clamp before opening
the case.
Be careful when working with voltages that exceed 30V ac rms, 42.4V
pk, or 60V dc.
The Current Clamp is protected throughout by double insulation. When
servicing the Current Clamp, use only specified replacement parts.
Caution
If the Current Clamp is to be Calibrated, you must have a replacement
decal. See the Replacement Parts section for further details.
This Current Clamp contains parts that can be damaged by static dis-
charge. Follow the standard practices for handling static sensitive de-
vices.
Introduction
Service Information covers the following service-related areas for the i410/i1010 AC/DC Current
Clamps:
Product specifications
Required equipment
Performance test procedure and test values
Preparing for calibration
Calibration procedure
Reassembly procedure
Replacement parts
Usually, service information in this document applies to both models (i410 and i1010). Information ap-
plicable to only one model is so noted. For operating information, refer to the Instruction Sheet that came
with the Current Clamp.
®
i410/i1010
AC/DC Current Clamp
2
Service Under Warranty
The Current Clamp is warranted to be free from defects in material and workmanship for one year.
The warranty does not cover abuse, batteries, or damage caused by using the Current Clamp outside its
rated specifications or operating environment. The complete warranty statement appears in the Current
Clamp Instruction Sheet.
For repairs:
In the USA or Canada, call 1-800-323-5700
Outside the USA, contact your nearest Fluke Distributor or Service Center.
Service, repairs, and replacement parts are warranted for 90 days.
Specications
General specifications are shown in Table 1. Range and accuracy specifications are shown in Table 2.
The accuracy of the Current Clamp is specified for one year after calibration, at 1C to 28°C (64°F to
82°F), with relative humidity to 90%.
Table 1. General Specifications
Operating Temperature -10 to 50°C (14 to 12F) Current x Hz Product 240,000
Storage Temperature Output Signal-20 to 60°C (-4 to 140°F) 1 mV per amp dc or ac
Relative Humidity 0 to 95% (0 to 30°C)
0 to 75% (30 to 4C)
0 to 45% (40 to 5C)
Working Voltage 600V CAT. III
maximum at input
Altitude
Operating
Non-operating
0 - 2000m
0 - 12000m
Maximum Conductor
Size
1 ea. 30 mm (1.18 in.)
diameter
2 ea. 25 mm (0.98 in.)
diameter
Battery Type 9V (alkaline) Load Impedance ≥ Ω1 M , 100 pF
Battery Life 60 hrs typical (continuous
with alkaline)
Temperature
Coefficient
+/-(0.05 x accuracy per °C
(0 -18°C, 28-50°C)
Safety s Double Insulation, 600V,
CAT. III
Size 209 x 78 x 48 mm (3.09 x
8.21 x 1.87 in.)
Weight 0.5 kg (17.6 oz.)
Table 2. Range and Accuracy Specifications
i410 i1010
Specied Current Range 1 - 400A ac rms *
1 - 400A dc
1 - 600A ac rms *
1 - 1000A dc
Usable Current Range 0.5 - 400A 0.5 - 1000A
DC Accuracy (zero adjusted,
conductor centered)
3.5% + 0.5A (0 - 400A) 2.0% + 0.5A (0-1000A)
AC Accuracy 3.5% + 0.5A, 45 - 400 Hz, Crest
Factor 3.
(1 - 400A)
2.0% + 0.5A, 45 - 400 Hz, Crest Factor 3.
3.0% + 0.5A, 400 Hz - 2 kHz sine wave.
(1 - 600A)
Bandwidth 3 kHz 10 kHz
*
With a true-rms DMM, the minimum ac current is limited to the low end of the specified mV ac range.


Produkt Specifikationer

Mærke: Fluke
Kategori: Ikke kategoriseret
Model: i410

Har du brug for hjælp?

Hvis du har brug for hjælp til Fluke i410 stil et spørgsmål nedenfor, og andre brugere vil svare dig




Ikke kategoriseret Fluke Manualer

Fluke

Fluke 1555 Manual

18 Juni 2025
Fluke

Fluke SB140 Manual

14 Juni 2025
Fluke

Fluke Pro3000 Manual

11 Marts 2025
Fluke

Fluke 438-II Manual

8 Oktober 2024
Fluke

Fluke 1670 Manual

8 Oktober 2024
Fluke

Fluke ii905 Manual

8 Oktober 2024
Fluke

Fluke ii915 Manual

8 Oktober 2024
Fluke

Fluke ii500 Manual

7 Oktober 2024
Fluke

Fluke T5-1000 Manual

4 Oktober 2024

Ikke kategoriseret Manualer

Nyeste Ikke kategoriseret Manualer