Læs gratis den danske manual til Fluke SureGrip 80PK-22 (5 sider) i kategorien Ikke kategoriseret. Denne vejledning er vurderet som hjælpsom af 19 personer og har en gennemsnitlig bedømmelse på 4.7 stjerner ud af 10 anmeldelser. Har du et spørgsmål om Fluke SureGrip 80PK-22, eller vil du spørge andre brugere om produktet?

Side 1/5
®
80PK-22
SureGripTM Immersion
Temperature Probe
Instruction Sheet
XWWarning
To avoid electrical shock, do not use this probe
when voltages exceeding 24 V ac rms or 60 V dc
are present. The probe tip is electronically
connected to the output terminals.
Introduction
The 80PK-22 SureGripTM Immersion Temperature Probe is
designed for use in liquids or gels. The probe can also be used
as a general purpose temperature probe. The thermocouple
junction is protected from tip to handle by an Inconel sheath.
The 40-inch (1 meter) cable is terminated with a Type K
miniature thermocouple connector with 0.792-mm (0.312-in)
pin spacing. The 80PK-22 can be used with any temperature-
measuring instrument that is designed to accept Type K
thermocouples and has a miniature connector input.
Note
The 80PK-22 is not recommended for use in food or
beverage preparation. Use 80PK-25 for food
preparation.
Specifications
Type
K Standard grade Ni-Cr vs. Ni-Al (Chromel vs. Alumel)
Measurement Range
-40 °C to 1090 °C (-40 °F to 1994 °F)
Accuracy
(With respect to ANSI MC96.1-1982-Standard Limits of Error)
Note
All error calculations should be done in °C, then
scaled to °F.
Range Accuracy
(% of reading)
-40 °C to 293 °C
(-40 °F to 559.4 °F)
±2.2 °C
293 °C to 1090 °C
(559.4 °F to 1994 °F)
±0.75 %
November 2004 Rev.2, 9/09
© 2004-2009 Fluke Corporation. All rights reserved
All product names are trademarks of their respective companies.
Output
@ 25 °C (77 °F) =1.00 mV (reference junction @ 0 °C)
Seebeck Coefficient
@ 25 °C (77 °F) = 40.50 μV / °C
Measurement Time
(Time Constant): 3.0 seconds in 100 C still water at sea level °
pressure. Complete step change equals 5 time constants (3.75
seconds).
Maximum Voltage
24 V ac rms or 60 V dc
Maximum Temperature of Tip
1090 ° °C (1994 F)
Sheath
Material: Alloy 600
Dimensions:
Diameter: 3.175 mm (1/8 in)
Length: 212.725 mm (8.375 in)
Grounding
Junction welded to sheath.
Cable
Length: 40 inches (1 meter)
Insulation
Material: PVC
Maximum Temperature: 105 °C (220 °F)
Jacket Color: Gray
Conductors
Type: K
Size: AWG #24 stranded (7 strands of #32)
Handle
Material: Hytrel
Maximum Temperature: 125 °C (257 °F)
Connector
Type: Mini-thermocouple connector with .792 mm (0.312 in)
pin spacing
Material: Yellow Hytrel
Maximum Temperature: 125 °C (257 °F)
Overall Length
31.75 cm (12.5 in) from probe tip to end of cable strain relief.
Protection
Class 3. Relates solely to insulation and grounding properties
defined in IEC 348.


Produkt Specifikationer

Mærke: Fluke
Kategori: Ikke kategoriseret
Model: SureGrip 80PK-22

Har du brug for hjælp?

Hvis du har brug for hjælp til Fluke SureGrip 80PK-22 stil et spørgsmål nedenfor, og andre brugere vil svare dig




Ikke kategoriseret Fluke Manualer

Fluke

Fluke 1630-2 FC Manual

25 August 2025
Fluke

Fluke 1746 Manual

2 August 2025
Fluke

Fluke P5510 Manual

2 August 2025
Fluke

Fluke 802EN Manual

2 August 2025
Fluke

Fluke T+Pro Manual

2 August 2025
Fluke

Fluke P5513 Manual

2 August 2025
Fluke

Fluke 6531 Manual

2 August 2025
Fluke

Fluke IRR2-BT Manual

2 August 2025

Ikke kategoriseret Manualer

Nyeste Ikke kategoriseret Manualer

Salton

Salton MP1206 Manual

31 August 2025
Pardini

Pardini K58 Manual

31 August 2025
Salton

Salton SCG-4 Manual

31 August 2025
Salton

Salton JK-1103 Manual

31 August 2025
Salton

Salton WC-2040 Manual

31 August 2025
Salton

Salton WC-2070 Manual

31 August 2025
Salton

Salton SP1963 Manual

31 August 2025
Gram

Gram EFI 8060-91 B Manual

31 August 2025