Fluke SureGrip 80PK-25 Manual

Fluke Ikke kategoriseret SureGrip 80PK-25

Læs gratis den danske manual til Fluke SureGrip 80PK-25 (5 sider) i kategorien Ikke kategoriseret. Denne vejledning er vurderet som hjælpsom af 24 personer og har en gennemsnitlig bedømmelse på 3.7 stjerner ud af 12.5 anmeldelser. Har du et spørgsmål om Fluke SureGrip 80PK-25, eller vil du spørge andre brugere om produktet?

Side 1/5
®
80PK-25
SureGripTM Piercing
Temperature Probe
Instruction Sheet
XWWarning
To avoid electrical shock, do not use this
probe when voltages exceeding 24 V ac rms
or 60 V dc are present. The probe tip is
electronically connected to the output
terminals.
Introduction
The 80PK-25 SureGripTM Piercing Temperature Probe is
designed for use in liquids, gels, soft, and semi-hard
materials. The probe is made of 316 stainless steel, which
is suitable for food service use. The thermocouple junction
of the probe is protected from tip to handle by the stainless
steel sheath. The 40-inch (1-meter) cable is terminated
with a Type K miniature thermocouple connector with
0.792-mm (.312-inch) pin spacing. The 80PK-25 can be
used with any temperature-measuring instrument that is
designed to accept Type K thermocouples and has a
miniature connector input.
Specifications
Type
K, Standard grade Ni-Cr vs Ni-Al (Chromel vs Alumel)
Measurement Range of Stainless Steel Probe
-40 °C to 350 °C (-40 °F to 662 °F)
Accuracy
(With respect to ANSI MC96.1 Standard Limits of Error)
Note
All error calculations should be done in °C, then
scaled to °F.
Range Accuracy
(% of reading)
-40 °C to 0 °C
(-40 °F to 32 °F)
±2.2 °C
0 °C to 350 °C
(32 °F to 662 °F)
±1.1 °C
November 2004 Rev.2, 10/09
© 2004-2009 Fluke Corporation. All rights reserved.
All product names are trademarks of their respective companies
Output
@ 25 °C (77 °F) =1.00 mV (reference junction at 0 °C)
Seebeck Coefficient
@ 25 °C (77 °F) = 40.50 μV / °C
Measurement Time
(Time Constant): 3.0 seconds in 100 °C still water at sea
level pressure (5 time constants = 1 complete step
change, i.e., 15 seconds)
Maximum Voltage
24 V ac rms or 60 V dc
Maximum Temperature of Tip 816 °C (1500 °F)
Sheath
Material: 316 Stainless Steel Dimensions
Diameter: 3.4036 mm (.134 in)
Length: 10.16 cm (4 in)
Tip: 25 ° conical
Grounding
Junction welded to sheath
Cable
Length: 40 inches (1 meter)
Insulation
Material: PVC
Maximum Temperature: 105 °C (221 °F)
Jacket Color: Gray
Food Service Limitation: The cable should not come in
contact with food.
Conductors
Type: K
Size: AWG #24 stranded (7 strands of #32)
Handle
Material: Hytrel (food service grade)
Maximum Temperature of Food in Contact with
Handle: 65 °C (150 °F)
Connector
Type: Mini-thermocouple connector with .792 mm (.0312
in) pin spacing
Material: Yellow Hytrel (food service grade)
Maximum Temperature: 125 °C (257 °F)
Overall Probe Length
22.23 cm (8.75 in) from tip to end of cable strain relief
Protection
Class 3. Relates solely to insulation and grounding
properties defined in IEC 348.


Produkt Specifikationer

Mærke: Fluke
Kategori: Ikke kategoriseret
Model: SureGrip 80PK-25

Har du brug for hjælp?

Hvis du har brug for hjælp til Fluke SureGrip 80PK-25 stil et spørgsmål nedenfor, og andre brugere vil svare dig




Ikke kategoriseret Fluke Manualer

Fluke

Fluke 1555 Manual

18 Juni 2025
Fluke

Fluke SB140 Manual

14 Juni 2025
Fluke

Fluke Pro3000 Manual

11 Marts 2025
Fluke

Fluke 438-II Manual

8 Oktober 2024
Fluke

Fluke 1670 Manual

8 Oktober 2024
Fluke

Fluke ii905 Manual

8 Oktober 2024
Fluke

Fluke ii915 Manual

8 Oktober 2024
Fluke

Fluke ii500 Manual

7 Oktober 2024
Fluke

Fluke T5-1000 Manual

4 Oktober 2024

Ikke kategoriseret Manualer

Nyeste Ikke kategoriseret Manualer