Frigidaire LRA12HZU2 Manual


Læs nedenfor 📖 manual på dansk for Frigidaire LRA12HZU2 (19 sider) i kategorien Klimaanlæg. Denne guide var nyttig for 33 personer og blev bedømt med 4.0 stjerner i gennemsnit af 17 brugere

Side 1/19
TA B L E O F C O N T E N T S
www.frigidaire.com USA 1-800-944-9044 www.frigidaire.ca Canada 1-800-265-8352
All about the
Use&Care
Care and Cleaning
.............................................. 9
Energy Saving Ideas ........................................... 9
2020213A0497 (June 2009)
Product Registration
...........................................................
3
Packaging 3
Normal Sounds .................................................... 3
.............................................
Air Conditioner Features 4.......................................
Important Safety Instructions ............................... 2 Operating Instructions 4-9.........................................
of your
Room Air Conditioner
Before You Call ................................................... 10
Major Appliance Warranty ................................... 11
Important Safety Instructions
READ THIS SECTION BEFORE ATTEMPTING TO OPERATE AIR CONDITIONER.
Unit must be upright for one hour prior to operating.
Plug in &
press RESET
The power supply cord contains a current device that senses damage to the power cord. To test
your power supply cord do the following:
Plug in the Air Conditioner.
The power supply cord will have TWO buttons on the plug head. Press the TEST button. You will
notice a click as the RESET button pops out.
Press the RESET button. Again you will notice a click as the button engages.
The power supply cord is now supplying electricity to the unit. (On some products this is also indi-
cated by a light on the plug head).
WARNING
For Your Safety
Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any
other appliance. Read product labels for flammability and other warnings.
WARNING
Prevent Accidents
To reduce the risk of fire, electrical shock, or injury to persons when using your air conditioner,
follow basic precautions, including the following:
Be sure the electrical service is adequate for the model you have chosen. This information
can be found on the serial plate, which is located on the side of the cabinet and behind the
grille.
If the air conditioner is to be installed in a window, you will probably want to clean both
sides of the glass first. If the window is a triple-track type with a screen panel included,
remove the screen completely before installation.
Be sure the air conditioner has been securely and correctly installed according to the
separate installation instructions provided with this manual. Save this manual and the
installation instructions for possible future use in removing or reinstalling this unit.
When handling the air conditioner, be careful to avoid cuts from sharp metal fins on front
and rear coils.
The complete electrical rating of your new room air conditioner is stated on the serial plate.
Refer to the rating when checking the electrical requirements.
Be sure the air conditioner is properly grounded. To minimize shock and fire hazards,
proper grounding is important. The power cord is equipped with a three-prong grounding
plug for protection against shock hazards.
Your air conditioner must be used in a properly grounded wall receptacle. If the wall
receptacle you intend to use is not adequately grounded or protected by a time delay fuse
or circuit breaker, have a qualified electrician install the proper receptacle.
Do not run air conditioner without outside protective cover in place. This could result in
mechanical damage within the air conditioner.
Do not use an extension cord or an adapter plug.
WARNING
Electrical Information
WARNING
Avoid fire hazard or electric shock. Do not
use an extension cord or an adaptor plug. Do
not remove any prong from the power cord.
NOTE:
The power supply cord with
this air conditioner contains a current
detection device designed to reduce the risk
of fire.
Please refer to the section ‘Operation of
Current Device’ for details.
In the event that the power supply cord is
damaged, it cannot be repaired. It must be
replaced with a cord from the product
manufacturer.
NOTE:
Do not use this device to turn the unit on or off.
Always make sure the RESET button is pushed in for correct operation.
The power supply cord must be replaced if it fails to reset when either the TEST button is pushed,
or it cannot be reset. A new one can be obtained from the product manufacturer.
If power supply cord is damaged, it CANNOT be repaired. It MUST be replaced by one obtained
from the product manufacturer.
22009 Electrolux Home Products, Inc. All rights reserved.
NOTE:
This USE & CARE MANUAL provides specific operating instructions for your model. Use the room air conditioner only as
instructed in this USE & CARE MANUAL. These instructions are not meant to cover every possible condition and situation that
may occur. Common sense and caution must be practiced when installing, operating, and maintaining any appliance.
115V
15A 230V
15A
230V
20A
Do not, under any
circumstances, cut,
remove or bypass the
grounding prong.
230V
30A
Grounding Prong
Record Your Model and Serial Numbers
Record in the space provided below the model and serial numbers. On all models, the
serial plate is located on the outside of the cabinet.
Model No.
Serial No.
Register Your Product
The self-addressed PRODUCT REGISTRATION CARD should be filled in completely,
signed and returned to the Frigidaire Company.
Packaging
Normal Sounds
Remove all packaging from inside the carton, along with any
inserts placed into the side louvers.
Remove the plastic ties and foam pad that secure the
compressor to the fan shroud (where applicable). See diagram.
Today’s high efficiency compressors
may have a high pitched chatter
during the cooling cycle.
High pitched Chatter
Unit may vibrate and make noise
because of poor wall or window
construction or incorrect installation.
Vibration
Pinging or Swishing
Droplets of water hitting condenser
during normal operation may cause
“pinging or swishing” sounds.
Sound of Rushing Air
At the front of the unit, you may
hear the sound of rushing air
being moved by the fan.
Gurgle/Hiss
“Gurgling or hissing” noise may be heard
due to refrigerant passing through
evaporator during normal operation.
Product Registration
3
Product Registration, Packaging & Normal Sounds
foam pad + plastic ties Packing Inserts
2009 Electrolux Home Products, Inc. All rights reserved.
4
Air Conditioner Features & Operating Instructions
Before you begin, thoroughly familiarize yourself with the control panel and remote
as shown below and all its functions, then follow the symbol for the functions you
desire. The unit can be controlled by the touch pad alone or with the remote.
ELECTRONIC CONTROL
NOTE
The following instructions represent the Touch Pad, the same instructions can be used for the Remote Control.
Air Conditioner Features
TO TURN UNIT ON: YOU WILL SEE:
Operating Instructions
2009 Electrolux Home Products, Inc. All rights reserved.
ADJUSTS
TEMPERATURE
OR TIME
DISPLAYS
TEMPERATURE/TIME
SETS FAN
SPEED
SETS MODE
TURNS UNIT
ON OR OFF
ACTIVATES
TIMER
CHECK FILTER
RESET BUTTON
SLEEP MODE
PRESS ON/OFF
BUTTON
DO THIS:
Turn Remote Control upside down. Squeeze tab and
pull to remove battery tray. Place battery in tray with
POSITIVE(“+”) side facing UP, according to diagram.
Re-insert battery tray.
Battery Size: CR2025
TO REPLACE BATTERY
TAB
REMOTE CONTROL
6
Operating Instructions
Operating Instructions
(continued)
TO OPERATE ON FAN ONLY: YOU WILL SEE:
Note: Use this function only when cooling is not desired, such as for room air circulation or to exhaust stale air on some models.
(Remember to open the vent during this function, but keep it closed during cooling for maximum cooling efficiency.) You can
choose any fan speed you prefer. (Except “Auto Fan”).
During this function, the display will show the actual room temperature, not the set temperature as in the cooling mode. Fan Only
cannot be selected when the unit is in the “Remote Sensing” mode. (on those units with that feature).
TO USE THE ENERGY SAVER FEATURE: YOU WILL SEE:
TIMER: DELAY STOP / START FEATURE YOU WILL SEE HOW MUCH TIME IS
CHOSEN:
Note: In this mode, the fan will continue to run for 1 minute after the compressor shuts off. The fan then cycles on for 20 seconds
at 10 minute intervals until the room temperature is above the set temperature, at which time the compressor turns back on.
Note: For Delay Stop, the unit must be in the On position
Note: For Delay Start, the unit must be in the Off position.
2009 Electrolux Home Products, Inc. All rights reserved.
DO THIS:
PRESS
MODE BUTTON
CHOOSE
FAN ONLY
CHOOSE
ENERGY SAVER
DO THIS:
PRESS
MODE BUTTON
THEN
DO THIS:
PRESS
UP/DOWN
SET BUTTONS
FIRST
DO THIS:
PRESS
TIMER BUTTON
First, Press TIMER button, then adjust timer setting, tap or hold the UP arrow ( ) or the DOWN arrow ( ) to change delay
timer at 0.5 hour increments, up to 10 hours, then at 1 hour increments up to 24 hours. The control will count down the time
remaining until start (8, 7.5, 7, etc.). The Delay Start Operation automatically selects cooling with maximum Fan speed (if Cool,
Energy Saver, or Fan Only was the last mode selected) or heating with maximum Fan speed (if Heat was the last mode selected.
Note: On 115V models only low speed can be selected.) The temperature maintained will be the same as previously set. To change
the set temperature, press "COOL" then Up or Down arrows until the desired temperature is indicated on the display. After 5
seconds, the control will automatically change the display back to the hours remaining until the unit will start/stop. Pressing the
unit On/Off button at any time will cancel the Delay Start/Stop function. The Delay Start/Stop Feature will work until the unit either
starts or stops. Once that happens the above steps have to be repeated again.
8
Operating Instructions
Operating Instructions
(continued)
2009 Electrolux Home Products, Inc. All rights reserved.
ADDITIONAL THINGS YOU SHOULD KNOW
Now that you have mastered the operating procedure, here are more features in your control that you should become familiar with.
The "Cool" circuit has an automatic 3 minute time delayed start if the unit is turned off and on quickly.
This prevents overheating of the compressor and possible circuit breaker tripping. The fan will continue
to run during this time.
The control will maintain the set temperature within 2 degrees Fahrenheit, between 60F and 90F degrees (in cool mode), 55F
and 80F degrees (in heat mode).
There is a 2-Second delay for the compressor shutting down when selecting FAN ONLY/HEAT. This is to cover the possibility of
having to roll through to select another mode.
After a power outage, the unit will memorize the last setting and return the unit to the same setting once power is restored.
Fresh Air Vent Control (on some models 15~28.5K BTU)
The Fresh Air Vent allows the air conditioner to:
1. Recirculate inside air - Vent Closed (see Fig. 1)
2. Draw fresh air into the room - Fresh Air (see Fig. 2)
3. Exchange air from the room - Vent Open (see Fig. 3)
Fig. 1 (VENT CLOSED) Fig. 2 (FRESH AIR) Fig. 3 (VENT OPEN)
Note: When unit is shut off in the Heat Mode, the fan will continue to run for a few seconds to dissipate residual heat within the unit.
TO TURN UNIT OFF:
DO THIS:
PRESS
ON/OFF BUTTON
YOU WILL SEE:
TO CHANGE TEMPERATURE DISPLAY:
Note: The control is capable of displaying temperature in degrees Fahrenheit or degrees Celsius.
YOU WILL SEE:
DO THIS:
PRESS AND HOLD THE
UP/DOWN BUTTONS
TOGETHER FOR 3 SECONDS


Produkt Specifikationer

Mærke: Frigidaire
Kategori: Klimaanlæg
Model: LRA12HZU2

Har du brug for hjælp?

Hvis du har brug for hjælp til Frigidaire LRA12HZU2 stil et spørgsmål nedenfor, og andre brugere vil svare dig