BEFORE YOU BEGIN
Read these instructions completely and
carefully.
IMPORTANT Save these
instructions for local inspector’s use.
IMPORTANT Observe all
governing codes and ordinances.
Note to Installer Be sure to leave these
instructions with consumer.
Note to consumer Keep these
instructions for future reference.
Skill level Installation of this appliance
requires a qualified installer or electrician.
Proper installation is the responsibility of the
installer.
Product failure due to improper installation is
not covered under warranty.
FOR YOUR SAFETY:
If you did not receive an anti-tip bracket with your purchase,
call 1-800-626-8774 to receive one at no cost. (In Canada,
call 1-800-561-3344.) For installation instructions of the bracket,
visit: www.geappliances.com. (In Canada, www.geappliances.ca.)
Installation Instructions
Free-Standing Electric Ranges
MATERIALS YOU MAY NEED TOOLS YOU WILL NEED
Anti-Tip Bracket
Kit Included
(UL Listed 40 AMP)
4-Wire Cord 4‘ long OR
3-Wire Cord 4‘ long
Squeeze Connector
(For Conduit
Installations Only)
REMOVE PACKAGING MATERIALS: Failure to remove packaging
materials could result in damage to the appliance. Remove all packing parts from oven,
racks, heating elements and drawer. Also, remove protective film and labels on the outer
door, cooktop and control panel.
1
Drill with 1/8” Bit
Safety Glasses
Adjustable Wrench
Level
Tin Snips
Tape Measure
Pliers
1/4” Nut Driver
Questions? Call 1-800-GE-CARES (1-800-432-2737) or visit www.geappliances.com
In Canada, call 1-800-
561-3344
or visit www.geappliances.ca
WARNING
Before
beginning the installation, switch
power off at service panel and
lock the service disconnecting
means to prevent power from
being switched on accidentally.
When the service disconnecting
means cannot be locked,
securely fasten a prominent
warning device, such as a tag,
to the service panel.
PREPARE THE OPENING (FOR INDOOR USE ONLY)
See illustrations for all rough-in and spacing dimensions. The range may be placed with 0
clearance (flush) at the back wall and side walls of the cabinet.
2
21
2
21
2
712
25”
47
25
3
8
7”
141
2
On models with baking
or warming drawers,
electrical outlet must
not be in this area.
31
4
31
4
734
231
2
47”
297
8
253
8
45”
36”
SINGLE OVEN DOUBLE OVEN
A
NOTE C
B
A
C
Both
Sides
NOTE: Use a 4power cord to prevent interference
with the storage drawer. Power cords 412 to 6long
may have to be dressed to allow for proper drawer
closing.
MINIMUM DIMENSIONS BETWEEN COOKTOP,
WALLS AND ABOVE THE COOKTOP:
A. Make sure the wall covering, countertop, flooring
and cabinets around the range can withstand
the heat (up to 200°F) generated by the range.
B. Allow 30” minimum clearance between surface
units and bottom of unprotected wood or metal
cabinet, or allow a 24” minimum when bottom of
wood or metal cabinet is protected by no less
than 1/4” thick flame retardant millboard covered
with not less than No 28 MSG sheet metal,
(.015”), .015” thick stainless steel, .024”
aluminum or .020” copper.
Acceptable electrical outlet area.
Orient electrical receptacle so the
length is parallel to floor.
*GE-branded models have control
panels 30-
7⁄8” wide.
30”
47
5
8
30”
C. This appliance has been approved for 0” spacing to adjacent surfaces above the cooktop.
However, a 6minimum spacing to surfaces less than 15” above the cooktop and adjacent
cabinet is recommended to reduce exposure to steam, grease splatter and heat.
To reduce the risk of burns or fire when reaching over hot surface elements, cabinet storage
space above the cooktop should be avoided. If cabinet storage space is to be provided above the
cooktop, the risk can be reduced by installing a range hood that projects at least 5” beyond the
front of the cabinets. Cabinets installed above the cooktop must be no deeper than 13”.
2978
*
*
4”
4”
31-10677 08-08 JR
ELECTRICAL REQUIREMENTS
WARNING: This appliance must be properly grounded.
WARNING:
All new constructions, mobile homes, recreational vehicles and installations
where local codes do not allow grounding through neutral, require a 4-conductor UL-listed range cord.
WARNING: To prevent fire or shock, do not use an extension cord with this appliance.
WARNING: To prevent shock, remove house fuse or open circuit breaker before
beginning installation.
We recommend you have the electrical wiring and hookup of your range connected by a qualified
electrician. After installation, have the electrician show you how to disconnect power from the
range.
You must use a single-phase, 120/208 VAC or 120/240 VAC, 60 hertz electrical system. If you
connect to aluminum wiring, properly installed connectors approved for use with aluminum wiring
must be used.
Effective January 1, 1996, the National Electrical Code requires that new construction (not
existing) utilize a 4-conductor connection to an electric range. When installing an electric range
in new construction, mobile home, recreational vehicle, or an area where local codes prohibit
grounding through the neutral conductor, refer to the section on four-conductor branch circuit
connections.
Check with your local utilities for electrical codes which apply in your area. Failure to wire your
oven according to governing codes could result in a hazardous condition. If there are no local
codes, your oven must be wired and fused to meet the National Electrical Code, NFPA No.
70 latest edition, available from the National Fire Protection Association.
This appliance must be supplied with the proper voltage and frequency, and connected to an
individual, properly grounded, 40 amp (minimum) branch circuit protected by a circuit breaker
or time-delay fuse.
Use only a 3-conductor or a 4-conductor UL-listed range cord. These cords may be provided with
ring terminals on wire and a strain relief device.
A range cord rated at 40 amps with 125/250 minimum volt range is required. A 50 amp range
cord is not recommended but if used, it should be marked for use with nominal 1
38 diameter
connection openings. Care should be taken to center the cable and strain relief within the
knockout hole to keep the edge from damaging the cable.
The rating plate is located on the oven frame or on the side of the drawer frame.
3
Rating plate
SINGLE OVEN
Rating plate
DOUBLE OVEN
POWER CORD AND CONDUIT INSTALLATION
Remove wire cover (on the back of range) by removing screws using a 1/4” nut driver.
Do not discard these screws.
For power cord and 1” conduit only,
remove
the knockout ring (138) located on bracket
directly below the terminal block. To remove
the knockout, use a pair of pliers to bend the
knockout ring away from the bracket and
twist until ring is removed.
For 3/4” conduit installations only, purchase a squeeze connector matching the diameter
of your conduit and assemble it in the hole. Insert the conduit through the squeeze connector
and tighten. Allow enough slack to easily attach the wires to the terminal block.
NOTE: Do not install the conduit without a squeeze connector. The squeeze connector MUST
be installed before reinstalling the rear range wiring cover.
D
B
A
4
Wire cover
5 screws to
remove
wire cover
Knockout
ring in
bracket
Knockout ring
removed
Retaining
tabs
Back of range
Terminal block
(appearance
may vary)
Terminal block cover
Screw to
remove
terminal
block cover
Back of range
SINGLE OVEN DOUBLE OVEN
For power cord installations only
(see the next step if using conduit),
assemble the strain relief in the hole.
Insert the power cord through the strain
relief and tighten. Allow enough slack
to easily attach the cord terminals to
the terminal block. If tabs are present at
the end of the winged strain relief, they
can be removed for better fit.
NOTE: Do not install the power cord
without a strain relief. The strain relief
bracket MUST be installed before
reinstalling the rear range wiring
cover.
C
Power cord
Strain relief
Terminal
block
Bracket
Squeeze
connector Terminal block
Conduit Bracket
PROCEED TO STEP 5 OR 6.