TOOLS YOU WILL NEED MATERIALS YOU MAY NEED
Gas line shut-off valve
Pipe joint sealant or UL-approved pipe thread
tape with Teflon* that resists action of natural
and LP gases
Flexible metal appliance connector (1/2 I.D.).
A 5-foot length is recommended for ease of
installation but other lengths are acceptable.
Never use an old connector when installing a
new range.
Flare union adapter for connection to gas
supply line (3/4 or 1/2 NPT x 1/2 I.D.)
Flare union adapter for connection to pressure
regulator on range (1/2” ” NPT x 1/2 I.D.)
Liquid leak detector or soapy water.
*Teflon: Registered trademark of DuPont
Flat-blade
screwdriver
Pipe wrenches (2)
(one for backup)
Phillips
screwdriver
Open-end or
adjustable wrench
Pencil and ruler Level
Drill, awl or nail
IN THE COMMONWEALTH OF
MASSACHUSETTS
This product must be installed by a licensed
plumber or gas fitter.
When using ball type gas shut-off valves, they
shall be the T-handle type.
A flexible gas connector, when used, must not
exceed 3 feet.
Installation Instructions
Range
Questions? Call 1.800.GE.CARES (1.800.432.2737) or visit www.GEAppliances.com
BEFORE YOU BEGIN
,03257$17³ Save these instructions for
local inspector’s use.
,03257$17³ Observe all governing
codes and ordinances.
,03257$17³ Remove all packing
material and literature from oven before
connecting gas and electrical supply to range.
,03257$17³ To avoid damage to your
cabinets, check with your builder or cabinet
supplier to make sure that the materials used will
not discolor, delaminate or sustain other damage.
This oven has been designed in accordance with
the requirements of UL and CSA International
and complies with the maximum allowable wood
cabinet temperatures of 194°F (90°C).
Note to Installer – Be sure to leave these
instructions with consumer.
Note to consumer – Keep these instructions for
future reference.
Servicer – The electrical diagram is in an
envelope attached to the back of the range.
Proper installation is the responsibility of the
installer.
Product failure due to improper installation is not
covered under warranty.
Before installing your range on linoleum or any
other synthetic floor covering, make sure the
floor covering can withstand 180°F without
shrinking, warping or discoloring. Do not install
the range over carpeting unless a sheet of 1/4”
thick plywood or similar insulator is placed
between the range and carpeting.
Mobile Home - Additional Installation
Requirements
The installation of this range must conform to
the Manufactured Home Construction and Safety
Standard, Title 24 CFR, Part 3280 (formerly the
Federal Standard for Mobile Home Construction
and Saftey, Title 24, HUD Part 280). When such
standard is not applicable, use the Standard for
Manufactured Home Installations, ANSI A225.1/
NFPA 501A or with local codes.
In Canada, the installation of this range must
conform with the current standards CAN/CSA-
A240-latest edition, or with local codes.
When this range is installed in a mobile home, it
must be secured to the floor during transit. Any
method of securing the range is adequate as
long as it conforms to the standards listed above.
WARNING
FIRE OR EXPLOSION HAZARD
If the information in this manual is not followed
exactly, a fire or explosion may result causing
property damage, personal injury or death.
Installation must be performed by a qualified
installer.
Read these instructions completely and carefully.
Installation of this range must conform with
local codes, or in the absence of local codes,
with the National Fuel Gas Code, ANSI Z223.1/
NFPA.54, latest edition. In Canada, installation
must conform with the current Natural Gas
Installation Code, CAN/CGA-B149.1 or the current
Propane Installation Code, CAN/CGA-B149.2, and
with local codes where applicable. This range
has been design-certified by CSA International
according to ANSI Z21.1, latest edition and
Canadian Gas Association according to CAN/
CGA-1.1 latest edition.
When installing a gas appliance the use of old
flexible connectors can cause gas leaks and
personal injury. Always use a flexible NEW
connector.
Leak testing of the appliance shall be conducted
according to the manufacturer instructions.
The range must be electrically grounded in
accordance with local codes or, in the absence
of local codes, in accordance with the National
Electrical Code (ANSI/NFPA 70, latest edition).
In Canada, electrical grounding must be in
accordance with the current CSA C22.1 Canadian
Electrical Code Part 1 and/or local codes. See
Electrical Connections in this section.
Do not install this product with an air curtain
hood or other range hood that operates by
blowing air down on the cooktop. This airflow
may interfere with operation of the gas burners
resulting in fire or explosion hazard.
FOR YOUR SAFETY:
• A child or adult can tip the range and be killed.
• Install the anti-tip bracket to the wall or floor.
• Engage the range to the anti-tip bracket by sliding the
range back such that the foot is engaged.
• Re-engage the anti-tip bracket if the range is moved.
Failure to do so can result in death or serious burns
to children or adults.
Tip-Over Hazard
WARNING
WARNING
Before beginning
the installation, switch power off at
service panel and lock the service
disconnecting means to prevent power
from being switched on accidentally.
When the service disconnecting means
cannot be locked, securely fasten a
prominent warning device, such as a
tag, to the service panel.
If you did not receive an anti-tip bracket with your
purchase, call 1.800.626.8774 to receive one at no
cost. (In Canada, call 1.800.561.3344.) For installation
instructions of the bracket, visit: www.GEAppliances.com.
(In Canada, www.GEAppliances.ca.)
Anti-Tip Bracket
Kit Included


Produkt Specifikationer

Mærke: GE
Kategori: Komfur
Model: JGB450REKSS

Har du brug for hjælp?

Hvis du har brug for hjælp til GE JGB450REKSS stil et spørgsmål nedenfor, og andre brugere vil svare dig




Komfur GE Manualer

GE

GE JS645SLSS Manual

29 December 2026
GE

GE JGP3036DLBB Manual

28 December 2025
GE

GE JGS760BELTS Manual

23 December 2025
GE

GE JGP5536DLBB Manual

21 December 2025
GE

GE Profile PP9030SJSS Manual

15 November 2025
GE

GE ZDP36L4RDSS Manual

15 November 2025
GE

GE GRS500PVWW Manual

6 November 2025
GE

GE GRS500PVBB Manual

5 November 2025
GE

GE JGBS61DPCC Manual

15 Oktober 2025
GE

GE CHP90302TSS Manual

10 September 2025

Komfur Manualer

Nyeste Komfur Manualer

TriStar

TriStar PD-8975 Manual

29 December 2026
Technika

Technika TCI6040TE Manual

29 December 2026
AEG

AEG OIO84A00IT Manual

29 December 2026
Smeg

Smeg SIM3964N Manual

29 December 2026
Neff

Neff TMK4674 Manual

29 December 2026
Ilve

Ilve UP36 Manual

29 December 2026
AEG

AEG TH85IH50IB Manual

28 December 2025
Midea

Midea MIH740F98K0 Manual

28 December 2025
Pelgrim

Pelgrim IKA7193 Manual

28 December 2025