Læs gratis den danske manual til GE Profile JGP336AEVAA (8 sider) i kategorien Komfur. Denne vejledning er vurderet som hjælpsom af 20 personer og har en gennemsnitlig bedømmelse på 4.8 stjerner ud af 10.5 anmeldelser. Har du et spørgsmål om GE Profile JGP336AEVAA, eller vil du spørge andre brugere om produktet?

Side 1/8
INSTALLATION INSTRUCTIONS FOR YOUR NEW
30 s EALED GAS COOKTOP
Before you andbegin—Read these instructions completely carefully.
IMPORTANT-Save these instructions for local inspector’s use.
IMPORTANT-QBSER~ ALL GOVERNING CODES AND ORDINANCES.
Note Consumer.to toInstaller-Be sure leave these instructions with the
Note to Consumer—Keep these instructions with your CareUse and Book for future reference.
Note—This appliance must be properly grounded.
......... .. ................ . ............. ..
~:::j~ ,.:::::
#!WARNING: if the information in this manual is ~
%%...
# #not followed exactly, a fire or explosion may
# result causing property damage, personal [
~ injury or death. ::,::
,.,.,
:::::
::::
IMPORTANT SAFETY INSTRUCTIONS
This cooktop has been Americandesign certified by The
Gas Association according to ANSI 221.1 latest edition
and The Canadian Gas Association according to CAN/
CGA- 1.1 Latest Edition. You’ll find safety precautions
in your Use and Care book. Read them carefully.
Q Installation of this cooktop must conform with local
codes, codes,or in the absence of local with the Na-
tional Fuel Gas Code, ANSI 2223. 1-Latest Edition.
o In Canada, installation must conform with the
current Natural Gas Installation Code, CAN/CGA-
B149. 1 or Propanethe current Installation Code, CAN/
CGA-B 149.2, and with local codes where applicable.
Be sure your cooktop is installed properly by a
qualified installer or sexwice technician.
Pub. No. 31-10172
229c4053P038-1 1
~ This cooktop must be electrically grounded in accor-
dance with withlocal codes, or in their absence, the
National Electrical Code ANSI /NFPA No. 70-Latest
Edition. See Grounding Instructions on page 6.
In Canada, electrical grounding must be in accor-
dance with the current CSA/C22. 1 Canadian Electrical
Code Part 1 and/or local codes. See Electrical Connec-
tions.
Be sure mobilethe installation of this cooktop in a
home conforms with the Manufactured Home Construc-
tion and Safety Standard, Title 24 CFR, Part 3280. If this
standard standarddoes not apply, you must follow the
for Manufactured Home Installations ANSI A225. 1 and
Manufactured Home Installations, Sites, and Communi-
ties ANSI /NFPA 501A, or with local codes.
. In Canada, mobile home installation must be in
accordance with the current CAN/CSA Z240/MH Mobile
Home Installation Code.
Q Do not store items of interest to children in cabinets
above the cooktop. They could be seriously burned
climbing on the cooktop to reach them.
. To eliminate reaching over surface cabinetburners,
storage above burner should be avoided.
Adjust surface burner flame stze so it does not extend
beyond the theedge of cooking utensil.
o Never use your cooktop for warming or heating the
room. Prolonged use of the cooktop without adequate
ventilation can be hazardous.
TOOLS YOU WILL NEED
For cutting countertop—saber saw
For gas supply connection—pipe wrenches
For conversion from Natural to Propane gas-adjustable
open-end wrench and 7mm socket driver or 9/32”
nutdriver
For burner flame adjustment-Phillips head and blade-
type screwdrivers
ADDITIONAL MATERIALS YOU MAY NEED
. Gas line shut-off valve
@ Pipe joint sealant
1/2” pipe nipple
STEP 1: PREPARE THE OPENING. Provide adequate clearances between cooktop and
adjacent combustible surfaces.
I
1
1“ FROM BACKWALL
A
+12 1/2”4
j FROM CUTOUT
CENTER LINE
,
I
; M’ MIN. I
, TO CABINET 1 3314” MIN. ~
I
1CUARANCE
1
I
I
I
CLEARANCE
TO SIDE WALL
Make sure the wall coverings, countertop and cabinets
around the thecooktop can withstand heat (up 200”F)to
generated by the cooktop. 2
Forjlexible connection where Zocal codes permit:
c Flexible metal tubing (same 3/4” 1/2”or I.D. as
gas supply line)
. Adapter or union
For rigid connection: Pipe fittings as required.
STEP 2: PROVIDE ADEQUATE GAS SUPPLY
This cooktop is designed to operate naturalon gas
at 4“ of water column pressure. It is shipped from
the factory set for natural gas.
FOR PROPER OPERATION, THE MAXIMUM INLET
PRESSURE TO THE REGULATOR MUST BE NO
MORE THAN 14” OF WATER COLUMN PRESSURE.
For checking the theregulator, inlet pressure must
be at least 1“ (or 3.4 KPA) greater than the
regulator regulatoroutput setting. If the is set for
4“ of water column pressure, the inlet pressure
must be at least is5“. If the regulator set for 10’,
the inlet pressure must be at least 11”.
The gas supply line to the cooktop should be l/2”
or 3/4” pipe.
In Canada, flexible connectors must be single wall
metal connectors no Ionger than 6 feet in length.
PROPANE GAS ADJUSTMENTS
NOTE: The pressure regulator is set for natural
f$Ls. TO use Propane Gas, the regulator must be
converted.