Læs gratis den danske manual til GE Profile P2S975BEMBB (52 sider) i kategorien Komfur. Denne vejledning er vurderet som hjælpsom af 9 personer og har en gennemsnitlig bedømmelse på 5.0 stjerner ud af 5 anmeldelser. Har du et spørgsmål om GE Profile P2S975BEMBB, eller vil du spørge andre brugere om produktet?

Side 1/52
TOOLS YOU WILL NEED
1/4” Nut Driver Level Pipe Wrench
Tape Measure Drill Safety Glasses
Phillips Head Flat Head Wrench or Pliers
Screwdriver Screwdriver (for 1 7/16” Nut)
1
MATERIALS YOU MAY NEED
31-10641-3 03-09 JR
Printed in the United States
Questions? Call 800.GE.CARES (800.432.2737) or Visit our Website at: GEAppliances.com
In Canada, call 1.800.561.3344 or Visit our Website at: www.GEAppliances.ca
Installation
Self-Cleaning Dual Fuel
Instructions
Slide-In Range
P2S975
BEFORE YOU BEGIN
Read these instructions completely
and carefully.
IMPORTANT Save these
instructions for local inspector’s use.
IMPORTANT Observe all
governing codes and ordinances.
Note to Installer Be sure to leave these
instructions with the Consumer.
Note to Consumer Keep these
instructions for future reference.
Product failure due to improper installation
is not covered under the Warranty.
WARNING This appliance must
be properly grounded.
Proper installation is the responsibility
of the installer and product failure due
to improper installation is NOT covered
under warranty.
WARNING
Before beginning
the installation, switch power off at service
panel and lock the service disconnecting means
to prevent power from being switched on
accidentally. When the service disconnecting
means cannot be locked, securely fasten
a prominent warning device, such as a tag,
to the service panel.
IN THE COMMONWEALTH OF
MASSACHUSETTS:
This product must be installed by
a licensed plumber or gas fitter.
When using ball-type gas shut-off valves,
they shall be the T-handle type.
A flexible gas connector, when used,
must not exceed 3 feet.
PARTS INCLUDED
Anchor SleevesLag Bolts
(For Concrete Floors Only)
Shut Off ValvePipe Fittings
CSA-Approved Flexible Gas Line
3/8Min. ID, 1/2NPT Connection,
3-foot Maximum Length (Massachusetts only)
Joint Sealant
Screws
Rear Filler
2 Screws
FOR YOUR SAFETY
If you did not receive an anti-tip bracket with your
purchase, call 1.800.626.8774 to receive one at no cost.
(In Canada, call 1.800.561.3344.)
For installation instructions of the bracket, visit:
GEAppliances.com. (In Canada, www.GEAppliances.ca.)
Anti-Tip Bracket
Kit Included
2
Installation Instructions
FOR YOUR SAFETY:
WARNING If the information
in this manual is not followed exactly, a fire,
explosion or gas leak may result causing
property damage, personal injury or death.
Do not store or use gasoline or other
flammable vapors and liquids in the vicinity
of this or any other appliance!
WHAT TO DO IF YOU
SMELL GAS:
Do not try to light any appliance. Do not
touch any electrical switch; do not use any
phone in your building.
Immediately call your gas supplier from a
neighbors phone. Follow the gas supplier’s
instructions.
If you cannot reach your gas supplier,
call the fire department.
Installation and service must be performed
by a qualified installer, service agency or
the gas supplier.
IMPORTANT SAFETY INSTRUCTIONS
This range has been design certified by
UNDERWRITERS LABORATORIES for use in
the United States and Canada. You’ll find
safety precautions in your Owner’s Manual.
Read them carefully.
Installation of this range must conform with
local codes or in the absence of local codes
with the National Fuel Gas Code, ANSI
Z223.1–Latest edition.
Be sure your range is installed properly by
a qualified installer or service technician.
To eliminate reaching over surface burners,
cabinet storage above burner should be
avoided.
Do not install the unit near an outside door
or where a draft may affect its use.
FOR YOUR SAFETY:
WARNING For personal safety,
remove house fuse or open circuit breaker
before beginning installation. Failure to do so
could result in serious injury or even death.
All rough-in and spacing dimensions must be
met for safe use of your range. Electricity to
the range can be disconnected at the outlet
without moving the range if the outlet is in
the preferred location (remove lower drawer).
To reduce the risk of burns or fire when
reaching over hot surface elements, cabinet
storage space above the cooktop should be
avoided. If cabinet storage space is to be
provided above the cooktop, the risk can
be reduced by installing a range hood that
protrudes at least 5” beyond the front of the
cabinets. Cabinets installed above a cooktop
must be no deeper than 13”.
Be sure your appliance is properly installed
and grounded by a qualified technician.
Rating
plate location
ELECTRICAL REQUIREMENTS
This appliance must be supplied with the
proper voltage and frequency and connected
to an individual, properly grounded branch
circuit, protected by a circuit breaker or fuse
having a recommended amperage rating per
the table below.
BREAKER OR FUSE SIZE
240V 40 Amps
208V 40 Amps
NOTE: Check Local Codes for required
breaker size.
Rating plate is located above the storage drawer
below the oven frame.
We recommend you have the electrical wiring
and hookup of your range connected by a
qualified electrician. After installation, have the
electrician show you where your main range
disconnect is located.