Honeywell 3310D Manual


Læs gratis den danske manual til Honeywell 3310D (14 sider) i kategorien Vault. Denne vejledning er vurderet som hjælpsom af 30 personer og har en gennemsnitlig bedømmelse på 4.6 stjerner ud af 15.5 anmeldelser. Har du et spørgsmål om Honeywell 3310D, eller vil du spørge andre brugere om produktet?

Side 1/14
LOST OR FORGOTTEN USER CODES
LOSS OF PRIMARY USER CODE
If the 3-8 digit Primary user code is lost or forgotten you can enter a new 3-8 digit Primary
user code by opening the safe with the 3-8 digit secondary user code and using red reset
button located on the inside edge of the door.
Once the safe is open follow the instruction on how to REPROGRAM A NEW PRIMARY
USER CODElocated at the bottom of page 1
LOSS OF SECONDARY USER CODE
If the 3-8 digit Secondary user code is lost or forgotten you will not be able to reprogram a
new Secondary user code.
You will be able to continue using the safe with the 3-8 digit Primary user code but will lose
the ability to have a Secondary user code.
IMPORTANT: To avoid losing the ability to continue using a Secondary user code it is very
important that the 3-8 digit Secondary user code is recorded when it is programmed and
kept in a secure location away from the safe.
LOSS OF BOTH PRIMARY AND SECONDARY USER CODES
If both the Primary user code and Secondary user codes are lost, you may open the safe
using the Emergency Override Access key and use the red user code reset button to
reprogram the 3-8 digit Primary user code.
The instructions for opening the safe with the Emergency Override Access key are below.
OVERRIDE ACCESS KEY
Your safe is equipped with an emergency override access key lock which allows immediate
access in case you forget your User codes or the batteries need replacing.
1. To access the compartment, locate the
tab at the top of the keypad.
2. Place your hand on the keypad tab and
pull forward.
3. With the tab pulled forward, rotate the
keypad counterclockwise to the left and
pull keypad out.
4. Insert the override key into the keyhole
on the inside of the lock and turn the key
to the right to unlock the safe.
5. Once the safe is opened, position the
keypad back onto the mounted bracket
and rotate clockwise to the right to lock
in place.
1.
2.
3.
4.
SECURE LOCKOUT PERIOD
If the wrong user code is entered into the keypad 4 consecutive times in a row, the keypad
will automatically revert to the lockout mode and you will not be able to open the safe using
the digital keypad for 3 minutes. During the lockout period entry can be made using the
emergency override key. Continued entry of the wrong user code will cause additional 3
minute lockouts until the proper user code is entered.
3
ATTENTION!
This Honeywell Executive Safe includes a new
Dual User Code Digital Lock. This update replaces
the User Code Programming Instructions located
on Page 3 of the Owner’s Manual for Executive
Safe Models 3014D, 3018D, 3024D, 3032D,
3114D, 3118D, 3124D, 3132D, 3310D, 3330D,
3350D, 3410D, 3430D, & 3450D
DUAL USER CODE DIGITAL LOCK
PRIMARY & SECONDARY USER CODE
PROGRAMMING INSTRUCTIONS
IMPORTANT UPDATE!
PRIMARY & SECONDARY USER CODES
Your new safe is equipped with a digital lock that can be operated with two separate user
codes. You will need to program these user codes with your own 3-8 digit user codes. It is
recommended that you record your new user codes and keep in a secure location away
from the safe. You must program the Primary user code first. After the Primary user code
is programmed and tested you can then proceed to program the Secondary user code.
PRIMARY USER CODE
UNLOCK AND OPEN SAFE
IMPORTANT: Always make sure that the spindle handle is turned counterclockwise to the
left before entering user code.
1. Open your new safe by entering 1-2-3-4-5-6 followed by the # key on the keypad.
2. After user code is entered, the keypad will beep once and the green LED will light up.
!
3. Turn the spindle handle to the right (clockwise) to open. !
NOTE: You must open the safe within 5 seconds or the safe will relock.!
PROGRAM THE PRIMARY USER CODE
1. With door open, locate and press the red reset button
located on the inside edge of the door (see illustration), the
keypad will beep twice and the green LED will light up.
2. Enter a new 3-8 digit Primary user code followed by the #
key. The green LED will light up and the keypad will beep.
3. Immediately re-enter the new 3-8 digit user code a second
time followed by the # key and the green LED will flash
twice and the keypad will beep twice.
4. This new Primary user code is now active.
TEST THE PRIMARY USER CODE
1. With door open, rotate handle counterclockwise to put door bolts in lock position.
2. Enter the new 3-8 digit Primary user code followed by the # key. The green LED will
light up and the keypad will beep.
3. Rotate the spindle handle clockwise within 5 seconds.
4. The lock bolts should recede into the unlocked position when the handle is turned.
REPROGRAM A NEW PRIMARY USER CODE
In the future, this user code can always be changed by opening the safe and using the
reset button.
1. Once the safe door is open, locate and press the small reset button located on the
inside edge of the door, the keypad will beep twice and the green LED will light up.
2. Enter a new 3-8 digit Primary user code followed by the # key, the green LED will
again light up and the keypad will beep.
3. Immediately re-enter the new 3-8 digit user code a second time followed by the # key
and the green LED with flash twice and the keypad will beep twice.
4. This new Primary user code is now active and the old Primary user code is deleted.
1
SECONDARY USER CODE
PROGRAM THE SECONDARY USER CODE
Once you have successfully programmed the Primary user code, you can proceed to
programming the Secondary user code. The Secondary user code is programmed using
the Digital Keypad and it is not necessary to open the safe to proceed.
1. Using the keypad, press the
! button twice (!-!)
2. Enter the factory default user code 1-2-3-4-5-6 followed by the # key into the keypad.
3. The green LED with light up once and the keypad will beep twice.
4. Enter a new 3-8 digit Secondary user code followed by the # key and the green LED
will again light up and the keypad will beep.
5. Immediately re-enter the new 3-8 digit Secondary user code a second time followed
by the # key and the green LED will flash twice and the keypad will beep twice.
6. After the new secondary user code is programmed, the factory preset user code will be
erased and the safe can only be unlocked using your new Primary or Secondary user
codes.
IMPORTANT: To change the secondary user code, the current user code will be
required. For this reason, it is very important that it is recorded and kept in a
secure location away from the safe.
TEST THE SECONDARY USER CODE
1. With door open, rotate handle counterclockwise to put door bolts in lock position.
2. Enter the new 3-8 digit Secondary user code followed by the # key. The green LED
will light up and the keypad will beep.
3. Rotate handle clockwise within 5 seconds.
4. The lock bolts should recede into the unlocked position when the handle is turned.
REPROGRAM A NEW SECONDARY USER CODE
1. Using the keypad, press the ! button twice (!-!)
2. Enter the current 3-8 digit Secondary user code followed by the # key into the keypad.
3. The green LED with light up once and the keypad will beep twice.
4. Enter a new 3-8 digit secondary user code followed by the # key and the green LED
will again light up and the keypad will beep.
5. Immediately re-enter the new 3-8 digit secondary user code a second time followed by
the # key and the green LED will flash twice and the keypad will beep twice.
OPENING/CLOSING SAFE WITH USER CODES
1. Make sure the spindle handle is positioned to the left and enter your new user code
into the keypad followed by the # key.
2. The keypad will beep once, green LED will light up and the lock will click. Turn the
handle clockwise to the right to open the safe.
3. To lock, close the door and turn the spindle handle counterclockwise to the left.
2


Produkt Specifikationer

Mærke: Honeywell
Kategori: Vault
Model: 3310D

Har du brug for hjælp?

Hvis du har brug for hjælp til Honeywell 3310D stil et spørgsmål nedenfor, og andre brugere vil svare dig




Vault Honeywell Manualer

Honeywell

Honeywell 5005P Manual

29 December 2024
Honeywell

Honeywell 1533 Manual

2 September 2024
Honeywell

Honeywell 5605W Manual

31 August 2024
Honeywell

Honeywell 5605 Manual

31 August 2024
Honeywell

Honeywell 5605B Manual

31 August 2024
Honeywell

Honeywell 5605P Manual

31 August 2024
Honeywell

Honeywell 1553 Manual

30 August 2024
Honeywell

Honeywell 5705 Manual

28 August 2024
Honeywell

Honeywell 5912 Manual

28 August 2024
Honeywell

Honeywell 1106W Manual

28 August 2024

Vault Manualer

Nyeste Vault Manualer