Læs gratis den danske manual til Hotpoint HTDX100GMWW (12 sider) i kategorien Tørretumbler. Denne vejledning er vurderet som hjælpsom af 14 personer og har en gennemsnitlig bedømmelse på 4.4 stjerner ud af 7.5 anmeldelser. Har du et spørgsmål om Hotpoint HTDX100GMWW, eller vil du spørge andre brugere om produktet?

Side 1/12
WARNING RISK OF FIRE
To reduce the risk of severe injury or death, follow all installation instructions.
&ORWKHVGU\HULQVWDOODWLRQPXVWEHSHUIRUPHGE\DTXDOL¿HGLQVWDOOHU
Install the clothes dryer according to these instructions and in accordance with local
codes. In the absence of local codes, installation must comply with National Fuel Gas
Code, ANSIZ223.1/NFPA 54 or the Canadian Natural Gas and Propane Installation
Code, CSA B149.1.
California Safe Drinking Water and Toxic Enforcement Act.
This act requires the governor of California to publish a list of substances known to
the state to cause cancer, birth defects or other reproductive harm and requires
businesses to warn customers of potential exposure to such substances. Gas
appliances can cause minor exposure to four of these substances, namely benzene,
carbon monoxide, formaldehyde and soot, caused primarily by the incomplete
combustion of natural gas or LP fuels. Properly adjusted dryers will minimize
incomplete combustion. Exposure to these substances can be minimized further by
properly venting the dryer to the outdoors.
This dryer must be exhausted to the outdoors.
Use only 4rigid metal ducting for exhausting the clothes dryer to the outdoors.
DO NOTLQVWDOODFORWKHVGU\HUZLWKÀH[LEOHSODVWLFGXFWLQJPDWHULDOV,IÀH[LEOHPHWDO
(semi-rigid or foil-type) duct is installed, it must be UL listed and installed in accordance
with the instructions found in “Connecting The Dryer To House Venton page 6 of this
manual. Flexible venting materials are known to collapse, be easily crushed, and trap
OLQW7KHVHFRQGLWLRQVZLOOREVWUXFWGU\HUDLUÀRZDQGLQFUHDVHWKHULVNRI¿UH
Do not install or store this appliance in any location where it could be exposed to
water and or weather.
Save these instructions. (Installers: Be sure to leave these instructions with the
customer).
In the state of Massachusetts:
,QVWDOODWLRQ PXVW EH SHUIRUPHG E\ D TXDOL¿HG RU OLFHQVHG FRQWUDFWRU
SOXPEHURUJDV¿WWHUTXDOL¿HGRUOLFHQVHGE\WKHVWDWH
 :KHQXVLQJEDOOW\SHJDVVKXWYDOYHVWKH\VKDOOEH7KDQGOHW\SH
 $ÀH[LEOHJDVFRQQHFWRUZKHQXVHGPXVWQRWH[FHHGIHHW
Installation
Instructions
Gas Dryer
01
BEFORE YOU BEGIN
Read these instructions completely and
FDUHIXOO\
,03257$17 Save these instructions
for local inspector’s use.
,03257$17 Observe all governing
codes and ordinances.
1RWHWR,QVWDOOHU Be sure to leave these
instructions with the customer.
1RWH WR &XVWRPHU  Keep these
instructions with your Owner’s Manual for
future reference.
Before the old dryer is removed from
service or discarded, remove the dryer
door.
Inspect the dryer exhaust outlet and
straighten the outlet walls if they are bent.
Service information and the wiring
diagram are located in the control console.
Do not allow children on or in the appliance.
Close supervision of children is necessary
when the appliance is used near children.
Install the dryer where the temperature is
above 50°F for satisfactory operation of
the dryer control system.
Product failure due to improper installation
is not covered under the Warranty.
LEVEL
8" PIPE WRENCH
10" ADJUSTABLE WRENCHES
(x2)
SLIP JOINT PLIERS FLAT BLADE SCREWDRIVER
M ATERIALS YOU WILL NEED
EXHAUST HOOD
FLEXIBLE GAS LINE CONNECTOR
SOAP SOLUTION
FOR LEAK DETECTION
PIPE
COMPOUND
DUCT TAPE
GLOVES
SAFETY GLASSES
4" DIAM METAL ELBOW
4" DUCT CLAMPS
OR
4" SPRING CLAMPS
(x2)
(x2)
4" DIA. FLEXIBLE METAL (SEMI-RIGID)
UL LISTED TRANSITION DUCT
(IF NEEDED)
KIT WX08X10077 (INCLUDES 2 ELBOWS)
4" DIA. METAL DUCT
(RECOMMENDED)
4" DIA. FLEXIBLE METAL (FOIL TYPE)
UL LISTED TRANSITION DUCT
(IF NEEDED.)
234D2217P001 31-16735 10-13 GE
D
E
S
I
G
N
C
E
R
T
I
F
I
E
D
4XHVWLRQV"&DOO*(&$5(6RUYLVLWRXU:HEVLWHDW*($SSOLDQFHVFRP
,Q&DQDGDFDOORUYLVLWZZZ*($SSOLDQFHVFD
TOOLS YOU WILL
NEED
Installation Instructions
2
0LQLPXP&OHDUDQFH2WKHU7KDQ$OFRYHRU&ORVHW,QVWDOODWLRQ
Minimum clearance to combustible surfaces and for air opening are: 0 in. clearance both sides and 1 in. rear.
Consideration must be given to provide adequate clearance for installation and service.
GAS REQUIREMENTS
WARNING
Installation must conform to local codes and
RUGLQDQFHVRULQWKHLUDEVHQFHWKH1$7,21$/)8(/
*$6&2'($16,=
 7KLV JDV GU\HU LV HTXLSSHG ZLWK D 9DOYH  %XUQHU
$VVHPEO\ IRU XVH RQO\ ZLWK QDWXUDO JDV 8VLQJ
FRQYHUVLRQ NLW :(; \RXU ORFDO VHUYLFH
RUJDQL]DWLRQ FDQ FRQYHUW WKLV GU\HU IRU XVH ZLWK
SURSDQH/3JDV$//&219(56,2160867%(0$'(
BY PROPERLY TRAINED AND QUALIFIED PERSONNEL
AND IN ACCORDANCE WITH LOCAL CODES AND
25',1$1&(5(48,5(0(176
7KHGU\HUPXVWEHGLVFRQQHFWHGIURPWKHJDVVXSSO\
SLSLQJ V\VWHP GXULQJ DQ\ SUHVVXUH WHVWLQJ RI WKDW
V\VWHPDWDWHVWSUHVVXUHLQH[FHVVRI36,.3D
7KHGU\HUPXVWEHLVRODWHGIURPWKHJDVVXSSO\SLSLQJ
V\VWHP E\ FORVLQJ WKH HTXLSPHQW VKXWRȹ YDOYH
GXULQJDQ\SUHVVXUHWHVWLQJRIWKHJDVVXSSO\SLSLQJ
RIWHVWSUHVVXUHHTXDOWRRUOHVVWKDQ36,.3D
GAS SUPPLY
A 1/8-in.National Pipe Taper thread plugged tapping,
accessible for test gauge connection, must be installed
immediately upstream of the gas supply connection to
the dryer. Contact your local gas utility should you have
questions on the installation of the plugged tapping.
Supply line is to be 1/2-in. rigid pipe and equipped with
DQDFFHVVLEOHVKXWRȺZLWKLQIWRIDQGLQWKHVDPH
room with the dryer.
 8VH SLSH WKUHDG VHDOHU FRPSRXQG RU 7HÀRQ WDSH
appropriate for natural or LP gas.
 <RXPXVWXVHZLWKWKLVGU\HUDÀH[LEOHPHWDOFRQQHFWRU
listed connector ANSI Z21.24 / CSA 6.10. The length of
the connect shall not exceed 3 ft.
 &RQQHFWÀH[LEOHPHWDOFRQQHFWRUWRGU\HUDQGJDVVXSSO\
 2SHQVKXWRȺYDOYH
INTERNAL DUCT
OPENING CHECK THA T EXHAUST
HOOD DAMPER OPENS
AND CLOSES FREE LY.
WALL
TILT THE DRYER SIDEWAYS
AND REMOVE THE FOAM
SHIPPING PADS BY
PULLING AT THE SIDES
AND BREAKING THEM
AWAY FROM THE DRYER
LEGS. BE SURE TO
REMOVE ALL OF THE
FOAM PIECES AROUND
THE LEGS.
1PREPARING FOR INSTALLATION OF
NEW DRYER
7,3,QVWDOO\RXUGU\HUEHIRUHLQVWDOOLQJ\RXUZDVKHU
7KLVZLOODOORZEHWWHUDFFHVVZKHQLQVWDOOLQJGU\HU
H[KDXVW
DISCONNECTING GAS
5(029,1*/,17)520:$//(;+$867
OPENING
5HPRYHDQGGLVFDUGH[LVWLQJSODVWLFRUPHWDOIRLO
WUDQVLWLRQGXFWDQGUHSODFHZLWK8/OLVWHGWUDQVLWLRQ
GXFW
DISCONNECT AND DISCARD OLD
FLEXIBLE GAS CONNECTOR AND
OLD TRANSITION DUCTING
MATERIAL. REPLACE WITH NEW
CSA(AGA) APPROVED FLEXIBLE
GAS LINE CONNECTOR AND UL
APPROVED TRANSITION DUCT.
TURN GAS
SHUT-OFF VALVE
TO THE OFF
POSITION.
:$51,1* 1(9(55(86(2/'
)/(;,%/(&211(&7256
7KHXVHRIROGÀH[LEOHFRQQHFWRUVFDQFDXVHOHDNVDQG
SHUVRQDOLQMXU\$OZD\VXVHQHZÀH[LEOHFRQQHFWRUV
when installing gas appliances.
DRYER GAS SUPPLY CONNECTION
2"
2-5/8" 3/8" NPT MALE THREAD GAS SUPPLY
NOTE: Add to vertical dimension
the distance between cabinet
bottom to floor.
Gas clothes dryers input ratings are based on sea level
operation and need not be adjusted for operation at or
below 2000 ft. elevation.
For operation at elevations above 2000 ft., input ratings
should be reduced at a rate of 4 percent for each 1000
ft. above sea level.
Installation must conform to local codes and ordinances or,
in their absence, the NATIONAL FUEL GAS CODE, ANSI Z223.
$'-867,1*)25(/(9$7,21


Produkt Specifikationer

Mærke: Hotpoint
Kategori: Tørretumbler
Model: HTDX100GMWW

Har du brug for hjælp?

Hvis du har brug for hjælp til Hotpoint HTDX100GMWW stil et spørgsmål nedenfor, og andre brugere vil svare dig