Kenwood CAX-AD100 Manual


Læs gratis den danske manual til Kenwood CAX-AD100 (4 sider) i kategorien Ikke kategoriseret. Denne vejledning er vurderet som hjælpsom af 13 personer og har en gennemsnitlig bedømmelse på 4.6 stjerner ud af 7 anmeldelser. Har du et spørgsmål om Kenwood CAX-AD100, eller vil du spørge andre brugere om produktet?

Side 1/4
BEFORE USE
To ensure proper use, please read through this manual before using this product.
It is especially important that you read and observe WARNING and CAUTION in this manual.
Please keep the manual in a safe and accessible place for future reference.
Features of this product
This product measures the concentration of ethanol contained in exhaled breath and displays it as a digital number. You can
check for the presence of alcohol by simply blowing on the sensor part.
IMPORTANT SAFETY INSTRUCTION
# WARNING
The numerical value displayed on the breath alcohol tester "CAX-AD100" is a guide, it does not judge whether you can
drive a car or work on a machine. It cannot be used intentionally as a tool to help any illegal activity such as drunk driving,
or directly used for finding legal facts in an accident or damage case. Regardless of whether or not this product is used, the
parties involved in manufacturing and sales are not responsible for any acts or damages that are not legally permitted.
When using this product for operation management and business management, never operate or make a judgment
that depends only on this measurement results. We are not responsible for any damage or trouble caused by using this
product.
Do not use this product while driving a vehicle. Also, never use this product in games such as compete for the alcohol
concentration in the breath. There is a risk of death or serious injury if you deliberately drink alcohol to increase alcohol
levels.
# CAUTION
Precautions for use
1. Do not disassemble, modify or wash with water.
2. This product is a precision electronic device. Avoid any strong impact.
3. Do not sit down with this product in your trouser or skirt pocket as it may be damaged.
4. Do not handle with wet hands.
5. When you blow into it, please try not to release saliva from your mouth.
6. When using the hand strap, do not swing the main unit by holding the hand strap. It may cause harm to you or anyone
nearby, or it may cause a malfunction of this product.
7. Do not spray cigarette smoke or spray gas on the sensor. It may cause a malfunction.
8. Do not spray high concentration alcohol (ethanol) continuously. It may cause a malfunction.
9. Be careful not to pinch your fingers when opening or closing the cover or attaching the attachment.
10. Avoid measuring in places with odors, windy places, and hot and humid places.
(Appropriate operating temperature 0 °C to 35 °C)
Precautions for storage
1. Avoid humidity and direct sunlight, and do not store in a potential hot place such as in a car during a sunny day.
(Storage temperature -10 °C to 60 °C)
2. Do not put perfume, cosmetics, etc. in a bag or case together, or store in a place with a strong odor.
3. Keep out of the reach of children.
4. Do not store near an air conditioner.
5. If you do not use the product for a long time, remove the battery.
Breath Alcohol Tester
CAX-AD100
INSTRUCTION MANUAL
© 2021 JVCKENWOOD Corporation
# CAUTION
Precautions for cleaning
1. If the display panel becomes dirty, immediately wipe it with a soft, dry cloth.
* Do not use boiling water, water, thinner, etc.
Precautions when using after opening a new product or after long-term storage
Due to its characteristics, this product may be in a kind of standby state at the time of shipment or when it has not been
used for several days. When using this product after opening a new product or storing it for a long period of time, do the
following before measuring:
Slide the sensor cover to the top and shake this product 2-3 times to remove odors and moisture accumulated inside.
Perform "blank measurement" (press the ON / OFF switch to operate once or twice).
Even if it is stored in a bag or case, some odorous components may adhere to the sensor and it may not be possible to
measure accurately. Please use after performing blank measurement as described above.
If the product is used after opening a new product or after long-term storage without performing blank measurement,
an error message may be displayed even if exhaled breath is blown normally. Therefore, perform blank measurement
before use.
For continuous measurement
When measuring continuously, shake the main body lightly 2-3 times to remove the miscellaneous gas accumulated
inside it (Do not shake strongly).
If alcohol is detected, please measure it after a while (Errors are likely to occur until the sensor is in the initial state).
Understanding Breath Alcohol Tester
This product uses a high-sensitivity gas sensor that detects alcohol (ethanol). The gas sensor is a consumable item, not a
permanent one. When using the product daily, any deposits on the surface of the sensor element (saliva, atmospheric gas, dust,
condensation, tobacco tar, etc.) can cause erroneous measurements and measurement errors (no reaction).
In addition, due to the characteristics of the sensor, accuracy cannot be maintained if more than one year has passed since it was
purchased or used, or if it is measured more than 5,000 times. If you want to continue using this product, we recommend that you
replace it with a new one.
There are individual differences in exhalation. Depending on your physical condition, constitution, time of day, etc., this product
may detect alcohol (ethanol) even though you are not drinking alcohol.
Please use it after understanding these things as well.
* Things that may react with something other than alcohol :
1 After meals (especially fermented foods) / Immediately after ingesting energy drinks and beverages / Immediately 2 3
after smoking / After taking some medicine / Immediately after eating gum or tablet / After using toothpaste or 4 5 6
mouthwash / If you have bad breath / Fermentation gas from inside the body.7 8
If you experience any abnormalities such as "alcohol reaction does not occur even though you are drinking" or "alcohol reaction
occurs even though you are not drinking", discontinue use. If the troubleshooting does not help, please contact the store where
you purchased the product or the JVCKENWOOD Customer Support Center.
Information on Disposal of Old electrical and electorinic Equipment and Batteries (applicable for EU countries that
have adopted separate waste collection systems)
Products and batteries with the symbol (crossed-out wheeled bin) cannot be disposed as household wasete.
Old electrical and electorinic equipment and batteries should be recycled at a facility capable of handling
these items and their waste byproducts.
Contact your local authority for details in locating a recycle facility nearest to you.
Proper recycling and waste disposal will help conserve resources whilst preventing detrimental effects on
our health and the envitonment.


Produkt Specifikationer

Mærke: Kenwood
Kategori: Ikke kategoriseret
Model: CAX-AD100

Har du brug for hjælp?

Hvis du har brug for hjælp til Kenwood CAX-AD100 stil et spørgsmål nedenfor, og andre brugere vil svare dig




Ikke kategoriseret Kenwood Manualer

Kenwood

Kenwood KSC-50CR Manual

25 Marts 2025
Kenwood

Kenwood KRK-15B Manual

24 Marts 2025
Kenwood

Kenwood VGS-1 Manual

24 Marts 2025
Kenwood

Kenwood KSC-25LS Manual

24 Marts 2025
Kenwood

Kenwood KPG-46U Manual

24 Marts 2025
Kenwood

Kenwood KPG-43U Manual

24 Marts 2025
Kenwood

Kenwood CAX-AD100 Manual

18 Marts 2025
Kenwood

Kenwood kMix FPX935 Manual

22 Februar 2025
Kenwood

Kenwood kMix FPX937 Manual

22 Februar 2025
Kenwood

Kenwood kMix FPX934 Manual

22 Februar 2025

Ikke kategoriseret Manualer

Nyeste Ikke kategoriseret Manualer

Rival

Rival CN753-W Manual

15 Juni 2025
Acopa

Acopa 553WSMKE Manual

15 Juni 2025
Atosa

Atosa RDCS-35 Manual

15 Juni 2025
Gourmia

Gourmia GAF692 Manual

15 Juni 2025
Taylor

Taylor 5315856 Manual

15 Juni 2025
Watts

Watts LF8B Manual

15 Juni 2025
Watts

Watts PLT-5 Manual

15 Juni 2025
ToiToiKids

ToiToiKids Fay Manual

15 Juni 2025
Aiphone

Aiphone JP-8Z Manual

15 Juni 2025