Kidde CV3106 Manual

Kidde Røgalarm CV3106

Læs gratis den danske manual til Kidde CV3106 (2 sider) i kategorien Røgalarm. Denne vejledning er vurderet som hjælpsom af 2 personer og har en gennemsnitlig bedømmelse på 4.6 stjerner ud af 1.5 anmeldelser. Har du et spørgsmål om Kidde CV3106, eller vil du spørge andre brugere om produktet?

Side 1/2
2. THE BEST AREAS TO INSTALL THE HEAT
ALARM:
Kitchen area
Garage or workshop
Additional alarms increase the security.
3. NOT AREAS WHERE TO INSTALL HEAT-
ALARMS:
In rooms where the temperature goes outside
-10ºC to +50ºC.
Lounge
Dining room
Hallway
Family room
NOTE: In areas where smoldering res occur
over aming res, photoelectric smoke alarms
are still the best to be installed.
4. PLACEMENT:
The heat alarm is design to be installed on a ceiling
or wall. Do not install to close to the oven/hob/
stove (see drawing).
For wall installation:
For celling installation:
5. INSTALLING THE HEAT ALARM:
Detach the alarm from the mounting base by
twisting counter clockwise.
MARK UP
SCREW HOLES
WITH A PEN
All alarms that need to be connected in the
house should be put into Learn Mode by sliding
the switch on the back of the alarm to the Learn
Mode position.
The red LED will light up to indicate that Learn
Mode has been selected.
Please note that when the alarms are placed
in Learn Mode they cant be inserted into the
mounting base.
Press and hold the test button at one alarm only,
until it beeps and the LED ashes. This alarm will
become the master and will start sending out a
specic house code to the other alarms.
As the other alarms receive the specic house
code, they will also ash the LED light.
When the red LED light flashes on all alarms,
they are connected and MUST BE SWITCHED
OUT OF LEARN MODEand installed.
Label the original Learn alarm in order to easily
add new CAVIUS Wireless Family alarms to the
system.
Thermal heat alarm device
Model no.: 3106
This Thermal Heat Alarm is designed for areas not
suitable for smoke alarms due to high risk of false
alarms such as; kitchens, garages or workshops.
PLEASE READ THE INSTALLATION GUIDE
CAREFULLY BEFORE INSTALLATION AND
RETAIN FOR FUTURE USE.
SAFETY INSTRUCTIONS:
The device comes with a 3V lithium battery. Bat-
teries are to be handled with care and battery pow-
ered devices should be kept out of reach of chil-
dren. Do not try to recharge or burn the batteries.
TECHNICAL INFORMATION:
Cavius heat alarm detects:
1) rapidly increased temperature level
2) absolute heat level of 58 degrees C.
The maximum number of alarms that can be inter-
linked within a house group are 32.
Please note: These must be alarms from the CAVIUS
The distance between interlinked alarms depends
on the house layout and they should always be
tested after installation. It is not advised to get
more than 10m distance between two alarms.
Diameter: 78mm. Height: 42mm.
The alarm is powered by a non-replaceable 3v
CR123A lithium battery.
1. HOW TO SET UP AND CONNECT ALARMS:
Please note: The product label must not be
removed as it contains important information
regarding the product.
UK
MOUNTING
BASE
TEST BUTTON
RED LED
THERMISTOR
Peak ceiling
Minimum 15cm
from peak
Minimum 15cm and
maximum 30cm from
ceiling
Wall
Ceiling
Minimum 30cm
and maximum 50cm
from stove
Ceiling
Minimum 30cm
from wall
Wall
Ceiling
LEARN MODE
NORMAL MODE
Heat
Siting of Heat alarms
Use the mounting base ring to mark the screw
holes on the ceiling or the wall.
Once the mounting base is installed, attach the
alarm by twisting clockwise until it clicks. If
the switch is in ‘Learn Mode’, the heat alarm will
not be able to click into the mounting base.
6. SAFETY LOCK:
7. TEST FUNCTION:
After installation, and at least once per quarter,
test all of your alarms to ensure they are operating
correctly and are within range of each other.
It is recommended to check visually every week if
the LED ashes correctly (every 48sec.)
Press the test button on any alarm for 2
sweeps of alarm signal. This will send out a
test signal from the alarm; all other connected
alarms should receive the signal within a short
time. The alarms will emit a short beep and the
LED will ash every 8 seconds for 2 minutes.
NOTE: Test function also allows to send a depleted
RF signal to ensure an optimal operation in normal
conditions.
When the test signal is sent out, the alarms will
respond in two ways:
1. A single beep every 8 seconds indicates that the
alarms are connected and functioning.
2. Three short beeps every 8 seconds indicates a
heat sensor fault.
If required this indication can be stopped early on
each alarm by a short press of the test button.
If the problem continues, please visit www.cavius.
com for any trouble shooting.
8. ADD EXTRA DEVICE:
All CAVIUS interconnected alarms within the
they run on the same frequency and use the same
data protocol.This means that the wireless system
can consist of a combination of smoke, heat etc.
Place all alarms into Learn Mode and repeat
section 1.
Always test connection to all devices by repeating
test function section 7 after adding devices.
The alarm effected by the low battery will only
beep, no other connected alarms will sound.
9. OTHER INFORMATION:
Do not paint the alarm.
Disposal: Please dispose properly at the end of
life. This is electronic waste which should be re-
cycled.
The heat alarm is not suitable for use as a re
safety device unless it is part of a planned re
safety system, i.e. when interconnected to one or
more smoke alarm(s).
RF Frequency: 868 MHz.
Maximum radio-frequency power transmitted: 20
mW
WARNING: All alarms should be assumed as due
to actual re and the dwelling should be evacuat-
ed immediately.
WARNING: To prevent injury, this apparatus must
be securely attached to the ceiling/wall in accor-
dance with the installation instructions.
WARNING: Batteries shall not be exposed to ex-
cessive heat such as shine, re, or the like.
Note the local country regulations regarding
installation.
Hereby, Carrier Fire & Security Danmark A/S de-
clares that the radio equipment type 3106 is in
compliance with Directive 2014/53/EU.
The full text of the EU declaration of conformity is
available at the following internet address: www.
cavius.com
The CE mark afxed to this product conrms its
compliance with the European Directives which
apply to the product.
BSI Kitemark™ certied.
Carrier assumes no responsibility for any errors,
which may appear in this manual. Furthermore,
Carrier reserves the right to alter the hardware,
software, and/or specications detailed herein
at any time without notice, and Carrier does not
make any commitment to update the infor mation
contained herein. ©2023 Carrier. All Rights Re-
served. All trademarks and service marks re-
ferred herein are property of their respective
owners.
Manufacturer: Carrier Fire & Security Danmark A/S,
Eller 9A, 2. Th, DK-2730. Made in China.
400147 rev7
CLICK THE HEAT ALARM
FIRMLY INTO THE BASE
TO LOCK
HEAT ALARM
SM ALARMOKE
M N REDAI S POWE
SM ALARMOKE
M N REDAI S POWE
HEAT ALARM
USE THE
ENCLOSED
SCREWS AND
PLUGS
MOUNT THE
SAFETY LOCK
BS 5446-2:2003
Class A1
KM 737251


Produkt Specifikationer

Mærke: Kidde
Kategori: Røgalarm
Model: CV3106

Har du brug for hjælp?

Hvis du har brug for hjælp til Kidde CV3106 stil et spørgsmål nedenfor, og andre brugere vil svare dig




Røgalarm Kidde Manualer

Kidde

Kidde CV3106 Manual

19 August 2025
Kidde

Kidde 3SFW Manual

19 August 2025
Kidde

Kidde i9060CA Manual

19 August 2025
Kidde

Kidde K10LLCO Manual

19 August 2025
Kidde

Kidde KF30LL Manual

19 August 2025
Kidde

Kidde Pi9010CA Manual

19 August 2025
Kidde

Kidde 900-0119 Manual

19 August 2025

Røgalarm Manualer

Nyeste Røgalarm Manualer

Emos

Emos P56503 Manual

15 August 2025
ORNO

ORNO OR-DC-640 Manual

12 August 2025
Schneider

Schneider FX101S Manual

11 August 2025
Schneider

Schneider FX101A Manual

10 August 2025
Hager

Hager WXH202 Manual

9 August 2025
FireAngel

FireAngel FS1226 Manual

2 August 2025
FireAngel

FireAngel SB1-R Manual

2 August 2025
FireAngel

FireAngel ST-625 Manual

2 August 2025