1. ad a instructions b ore wiring or using thisRe ll ef
heater.
2. WARNING: This heater is hot wh in use. Toen
avoid burns, do not let bare skin touch hot sur-
faces. Keep combustible materials, such as furni-
ture, pillows, bedding, paper clothes, boxes,s,
etc., and curtains at least 3ft (.9 m) from the
front of the heater and keep them away from the
sides and rear.
heater is used by or near children or in lids andva
wh
enever the heater is left operating and at-un
tended.
4. Do not operate any heater after it malfunctions.
D co ect power at service panel and h eis nn av
heater inspected by qualied electrician for re-
pair before reusing.
5. Do not use outdoors.
6. WARNING: To disconnect heater,
turn controls to OF and turnF,
OFF power to heater circuit at
IMPORTANT INSTRUCTIONS
ELECTRIC S CK OR FIRE HAZARDHO
DANGER
!
!
WARNING
!
!
Re efad Car ully - These instructions are written in an eort to prevent potential diculties that m ht arise during ig
insta at n. Studying the instructions rst may s e you considerable time and money later. Observing the fo owing ll io av ll
procedures will keep inst lat n time to a minimum. . al io Save these instructions for future use
1
Covers a W Se s models ll rie
W Fan Force Electric
Space Heater
King Electrical Mfg. Co. 9 th Ave So. Seattle, WA 9 206- 2- 00 www.king-electric.com 131 10 8108 76 04
IMPORTANT INSTRUCTIONS
When usin electrical heatin a liances asic precautio should always e ollowed to g g pp , b ns b f
reduce he risk of re, electric shock and injury to perso includin the ollowing: t ns, g f
main disconnect panel.
7. WARNING: Do not insert or allow foreign objects
to enter any ventilation or exhaust opening as this
may cause an electric shock, re, or damage to
the heater.
8. To prevent a possible of re, do not block air in-
takes or exhaust in any manner.
9. A heater has hot and arching or sparking parts
inside. Do not use it in areas where gasoline,
paint, or ammable vapors or liquids are used or
stored.
10. WARNING: Use this heater only as described in this
manual. Any other use is not recommended by the
manufacturer and may cause re, electric shock,
explosion or injury to people and or property.
!
SAVE T SE INSTRUCTIONS HE
Figure 1
!
!
!
Figure 2
!
ELECTRIC SHOCK OR FIRE HAZARD
!
!
Figure 3
2
W INSTALLATION INSTRUCTIONS
CAUTION!
Turn OFF all electrical power
to install heater
Rating Label Location
Total Amps
Minimum AWG. Wire
Size (Copper
Circuit Breaker or
Fuse Size
0 thru 12 15 amp #14
12.1 thru 16 20 amp #12
16.1 thru 24 30 amp #10
Minimum Clearances for heater: Table 1
Front TOP BOTTOM SIDES
36 in 12 in 4 in 6 in
0.9 m 30.5 cm 10.2 cm 15.2 cm
Selecting A Location For Your Heater:
DO NOT install less than 6” (15cm) from vertical side
walls or open edge of door. This heater must have an
unrestricted airflow. DO NOT select a location where it
is likely to be blocked by furniture, curtains, etc. Be
sure the location selected allows sufficient space for the
heater as shown by Table 1. DO NOT locate this heater
in an area where combustible vapors, gases liquids, or
excessive lint, dust or moisture is present.
The wire and breaker sizing chart will give a general rule
of installation size. Consult an electrician if you are not
knowledgeable about wiring codes.
Wire and Breaker Sizing: Table 2
WIRING: Branch Circuit Connection
1. Connect heater only to the voltage, amperage and
frequency specified on the nameplate.
2. Wiring procedures and connections shall be in accor-
dance with all National and local codes having juris-
diction.
3. Set the bag containing the grille and packet with
two (2) grille screws aside.
4. Loosen mounting screw and remove fan heater as-
sembly.
5. A knockout of 1/2 inch conduit size (7/8 inch /
2.2cm) is provided in the back and side of the heater
for power to enter. Provide proper strain relief con-
nectors for your wire entering the wallbox.
6. Install wallbox a minimum of 6” from vertical side-
walls and 4” above floor. The front edge of wall
can MUST extend 1/2” beyond finished wall sur-
face.
7. Secure wallbox to the 2 x 4 studs using the two (2)
holes on the side of the wallbox. Secure to wall stud
on opposite side if required.
8. Connect supply wires, attach ground feed wire to
the green ground wire with wire nuts.
9. Reinstall heater assembly into wallbox with screw at
top of interior.
10. Install grille securely with screws provided in
packet. Do not over tighten.
11. Test unit by turning thermostat up past room tem-
perature. You will see a puff of smoke as the ele-
ments are energized and the fan turns on. This is a
normal burn off of manufacturing lubricants and will
dissipate in 5 minutes.
12. Heater will continue to run until the room tempera-
ture you set is reached and then turn itself off until
the temperature drops again.
CAUTION - High temperature. Risk of fire , keep electri-
cal cords, drapery, furnishings, and other combusti-
bles at least 3 feet (0.9 m) from the front of the
heater as well as away from the side and rear. To
reduce the risk of fire, do not store or use gasoline or
other flammable vapors and liquids in the vicinity of the
heater.
Figure 2
Wiring Diagram Figure 5
Zero clearance to insulation.
Figure 4
!
DANGER


Produkt Specifikationer

Mærke: King
Kategori: Varmeapparat
Model: W2420-W

Har du brug for hjælp?

Hvis du har brug for hjælp til King W2420-W stil et spørgsmål nedenfor, og andre brugere vil svare dig




Varmeapparat King Manualer

Varmeapparat Manualer

Nyeste Varmeapparat Manualer

Lavex

Lavex 761AMLV75 Manual

15 Juni 2025
XPower

XPower A-12 Manual

15 Juni 2025
BEKO

BEKO RHO8323BT Manual

14 Juni 2025
XPower

XPower B-55 Manual

14 Juni 2025
XPower

XPower B-2 Manual

14 Juni 2025
XPower

XPower M-27 Manual

14 Juni 2025
XPower

XPower P-80 Manual

14 Juni 2025