La Nordica Giusy Evo Manual

La Nordica Komfur Giusy Evo

Læs gratis den danske manual til La Nordica Giusy Evo (32 sider) i kategorien Komfur. Denne vejledning er vurderet som hjælpsom af 13 personer og har en gennemsnitlig bedømmelse på 4.3 stjerner ud af 7 anmeldelser. Har du et spørgsmål om La Nordica Giusy Evo, eller vil du spørge andre brugere om produktet?

Side 1/32
MADE IN ITALY
design & production
GIUSY evo - GIUSY PLUS evo
004277265 - Rev 006
UK PeLLet StoveS USeR MANUAL
2ENGLISH
S
i
l
i
co
ne
GIUSY evo - GIUSY PLUS evo
ENGLISH
5ENGLISH
Warnings
This instructions manual is an integral part of the product: make sure that
it always accompanies the appliance, even if transferred to another owner
or user, or if transferred to another place. If it is damaged or lost, request
another copy from the area technician. This product is intended for the use
for which it has been expressly designed. The manufacturer is exempt from
any liability, contractual and extracontractual, for injury/damage caused to
persons/animals and objects, due to installation, adjustment and mainte-
nance errors and improper use.
Installation must be performed by qualied sta, which assumes com-
plete responsibility for the denitive installation and consequent good
functioning of the product installed. One must also bear in mind all laws
and national, regional, provincial and town council Standards present
in the country in which the appliance has been installed, as well as the
instructions contained in this manual.
The Manufacturer cannot be held responsible for the failure to comply
with such precautions.
After removing the packaging, ensure that the content is intact and com-
plete. Otherwise, contact the dealer where the appliance was purchased.
All electric components that make up the product must be replaced with
original spare parts exclusively by an authorised after-sales centre, thus
guaranteeing correct functioning.
safety
THE APPLIANCE MAY BE USED BY CHILDREN 8 YEARS OF AGE OR
OLDER AND INDIVIDUALS WITH REDUCED PHYSICAL, SENSORY, OR
MENTAL CAPACITIES OR WITHOUT EXPERIENCE OR THE NECESSARY
KNOWLEDGE, PROVIDED THAT THEY ARE SUPERVISED OR HAVE
RECEIVED INSTRUCTIONS ON SAFE USE OF THE APPLIANCE AND THAT
THEY UNDERSTAND THE INHERENT DANGERS.
THE GENERATOR MUST NOT BE USED BY PERSONS (INCLUDING
We thank you for having chosen our company; our product is a great heating solution developed from the
most advanced technology with top quality machining and modern design, aimed at making you enjoy the
fantastic sensation that the heat of a ame gives, in complete safety.
6ENGLISH
CHILDREN) WITH REDUCED PHYSICAL, SENSORY AND MENTAL
CAPACITIES OR WHO ARE UNSKILLED PERSONS, UNLESS THEY ARE
SUPERVISED AND TRAINED REGARDING USE OF THE APPLIANCE BY A
PERSON RESPONSIBLE FOR THEIR SAFETY.
THE CLEANING AND MAINTENANCE REQUIRED BY THE USER MUST
NOT BE PERFORMED BY CHILDREN WITHOUT SUPERVISION.
CHILDREN MUST BE CHECKED TO ENSURE THAT THEY DO NOT PLAY
WITH THE APPLIANCE.
DO NOT TOUCH THE GENERATOR WHEN YOU ARE BAREFOOT OR
WHEN PARTS OF THE BODY ARE WET OR DAMP.
THE SAFETY AND ADjUSTMENT DEVICES MUST NOT BE
MODIFIED WITHOUT THE AUTHORISATION OR INDICATIONS OF THE
MANUFACTURER.
DO NOT PULL, REMOVE, TWIST THE ELECTRICAL CABLES COMING
OUT OF THE PRODUCT EVEN IF IT IS DISCONNECTED FROM THE MAINS.
IT IS ADVISED TO POSITION THE POWER SUPPLY CABLE SO THAT IT
DOES NOT COME INTO CONTACT WITH HOT PARTS OF THE APPLIANCE.
THE POWER SUPPLY PLUG MUST BE ACCESSIBLE AFTER
INSTALLATION.
DO NOT CLOSE OR REDUCE THE DIMENSIONS OF THE AIRING VENTS
IN THE PLACE OF INSTALLATION. THE AIRING VENTS ARE ESSENTIAL
FOR CORRECT COMBUSTION.
DO NOT LEAVE THE PACKAGING ELEMENTS WITHIN REACH OF
CHILDREN OR UNASSISTED DISABLED PERSONS.
THE HEARTH DOOR MUST ALWAYS BE CLOSED DURING NORMAL
FUNCTIONING OF THE PRODUCT.
WHEN THE APPLIANCE IS FUNCTIONING AND HOT TO THE TOUCH,
ESPECIALLY ALL EXTERNAL SURFACES, ATTENTION MUST BE PAID
CHECK FOR THE PRESENCE OF ANY OBSTRUCTIONS BEFORE
SWITCHING THE APPLIANCE ON FOLLOWING A PROLONGED PERIOD
OF INACTIVITY.
THE GENERATOR HAS BEEN DESIGNED TO FUNCTION IN ANY
CLIMATIC CONDITION. IN PARTICULARLY ADVERSE CONDITIONS
(STRONG WIND, FREEzING) SAFETY SYSTEMS MAY INTERVENE
THAT SWITCH THE GENERATOR OFF. IF THIS OCCURS, CONTACT THE
TECHNICAL AFTER-SALES SERVICE AND ALWAYS DISABLE THE SAFETY
8ENGLISH
INSTALLING INSERTS
When installing inserts, access must be prevented to the internal parts of the appliance and it must not be possible to access live parts during
extraction operations.
Any wiring, for example the power cable or room probe, must be positioned so as not to be damaged during movement of the insert and must
not come into contact with hot parts. If a cavity made of combustible material is installed, we recommend taking all the safety precautions
indicated by the installation standards.
VENTILATION AND AERATION OF INSTALLATION ROOMS
In case of non-airtight heater and/or installation, the ventilation must respect the minimum area indicated below (considering the highest value
among those provided):
Appliance categories Reference standard
Percentage of the
net opening section with respect to the
appliance fumes outlet section
Minimum net opening value of the
ventilation duct
Pellet stoves UNI EN 14785 - 80 cm²
Boilers UNI EN 303-5 50% 100 cm²
INSTALLATION
GENERAL
The ue gas exhaust and hydraulic connections must be carried out by qualied personnel who must issue installation conformity
documentation compliant with national standards.
The installer must provide the owner or person acting for him, according to the legislation in force, with the declaration of conformity,
supplied with:
1) the use and maintenance manual of the appliance and of the system components (such as for example, the smoke ducts, chimney, etc.);
2) photocopy or photograph of the chimney plaque;
3) system booklet (where applicable).
The installer must ask to be issued with a receipt stating that the documentation has been provided, and must keep it with a copy of the technical
documentation relating to the installation.
For installation in a condominium, prior approval from the condominium's administrator must be requested.
Where required, check the exhaust gas emissions after installation. Should a sampling point be installed, it must be airtight.
COMPATIBILITY
Do not install in rooms with a re hazard. It is also forbidden to install it in living areas with the following characteristics:
1. where there are liquid fuel appliances with continuous or discontinuous operation that draw the combustion air into the room in which they
are installed.
2. where there are type B gas appliances intended for heating, with or without domestic hot water production and in adjacent and communicating
rooms.
3. where the depression measured in situ between the external and internal environment is greater than 4 Pa.
N.B.: Watertight appliances can also be installed in the cases indicated in points 1, 2 and 3 of this paragraph.
INSTALLATIONS IN BATHROOMS, BEDROOMS AND STUDIO FLATS
Installation in bathrooms, bedrooms and studio ats is only allowed for sealed or closed hearth appliances with ducted combustion air taken
from the outside.
oor protection
POSITIONING AND SAFETY DISTANCES
The support surfaces and/or points must have a suitable capacity to bear the overall weight
of the appliance, accessories and coverings. If the oor is made of a combustible material,
we recommend using a non-combustible material to protect the front part from any burnt
material which might fall during routine cleaning operations. The generator must be level
to function properly. The side walls, the rear walls and the oor support surface should be
made of non-combustible material.
A
C
B
One must also bear in mind all laws and national,
regional, provincial and town council regulations in force
in the country in which the appliance has been installed,
as well as the instructions contained in this manual.
Air inlet
Under any condition, including in the presence of extractor hoods and/or of controlled forced ventilation systems, the pressure dierence
between the generator installation rooms and the outside must always be equal to or less than 4 Pa.
MINIMUM DISTANCES
Installation next to ammable or heat-sensitive materials is permitted only if the special
safety distances specied on the label at the beginning of the manual (pag.2) are
observed. If the materials are not ammable, you must keep a side and rear distance of at
least 100 mm (without the inserts). For products equipped with rear spacers, wall-mounting
installation is permitted exclusively for the rear side.
PREPARATIONS FOR MAINTENANCE
To carry out extraordinary maintenance operations on the product, it may be necessary to move it away from the adjacent walls. This must be
done by a technician authorised to disconnect the combustion product evacuation ducts and then reconnect them. For heaters connected to the
hydraulic system, the connection between the system itself and the product must be made in such a way that, when an authorised technician is
about to carry out extraordinary maintenance operations, it is possible to move the heater at least 1 metre away from the adjacent walls.
3 - 5%
Max 3 mt
9ENGLISH
ExAMPlEs of coRREcT connEcTion To ThE chiMnEy
In the presence of type B gas appliances with intermittent operation not intended for heating, they must have their own aeration and/or
ventilation opening.
The air inlets must meet the following requirements:
they must be protected with grids, metal mesh, etc., but without reducing the net useful section;
they must be made so as to make the maintenance operations possible;
positioned so that they cannot be obstructed;
The clean and non-contaminated air ow can also be obtained from a room adjacent to that of installation (indirect aeration and
ventilation), as long as the ow takes place freely through permanent openings communicating with the outside.
The adjacent room cannot be used as a garage, or to store combustible material or for any other activity with a re hazard, bathroom,
bedroom or common room of the building.
Flue gas eXhaust
The heat generator works in depression and is equipped with an outlet fan for ue gas extraction. There must be a single exhaust system for
the generator. Using a ue that is shared with other devices is not allowed.
The components of the ue gas exhaust system must be chosen in relation to the type of appliance to be installed in compliance with:
UNI/ TS 11278 in the event of metal chimneys, with particular attention to that stated in the specication;
UNI EN 13063-1 and UNI EN 13063-2, UNI EN 1457, UNI EN 1806 in the event of non-metallic chimneys.
The length of the horizontal section must be minimal and, in any case, no longer than 3 metres, with a minimum upward slope of 3%
There must not be more than 4 direction changes including the one due to the use of the "T" element.
A “T tting with a condensation collection cap must be provided at the base of the vertical section.
If the exhaust is not inserted in an existing ue, a vertical section with a windproof end piece is required (UNI 10683).
The vertical duct can be inside or outside the building. If the smoke duct is inserted in an existing ue, it must be certied for solid fuel.
If the smoke duct is outside the building, it must always be insulated.
The smoke ducts must have at least one airtight inlet for ue gas sampling.
All the sections of the ue gas duct must be accessible to inspection.
Inspection openings must be provided for cleaning.
If the generator has a fume temperature lower than 160°C+ ambient temperature caused by the high yield (contact technicians) it
MUST be resistant to humidity.
A ue system that does not respect the previous points or, in general, that does not comply with the regulations, may cause condensation
phenomena inside it.
ChIMneY CaP
The chimney caps must meet the following requirements:
they must have a useful outlet section no less than double that of the chimney/ducted system on which it is installed;
they must be adapted in order to prevent the penetration of rain and snow in the chimney/ducted system;
they must be built so that, in the event of winds coming from all directions and from any angle, the expulsion of combustion products
is in any case ensured;
Protection from rain
and wind
Condensation-proof
"T" tting with
inspection plug
Insulated ue
Insulated "T"
tting with
inspection plug
Protection from rain and wind
"T" tting with
i n s p e c t i o n
plug
COnneCtIOn tO the MaIns eleCtrIC suPPlY
The generator is supplied with an electric power cable to be plugged into a 230V 50 Hz socket, possibly with a circuit breaker switch. The
socket must be easily accessible.
The electrical system must be compliant with standards. The eciency of the earthing circuit must be checked. Unsuitable earthing of the
system can cause malfunctioning for which the manufacturer will not be held liable.
Power supply variations beyond 10% can cause faulty operation of the product.
GIUSY PLUS evo
ENGLISH
HOT AIR DUCTING
The pipe destined for ducting the hot air must have an internal diameter of 80 mm, be insulated and protected from heat loss.
The length must not exceed 6 metres.
Installation of the pipes used for ducting the hot air must be performed by qualified staff and/or the manufacturer's technical after-
sales assistance.
FOR THIS PRODUCT IT IS MANDATORY TO DUCT THE HOT AIR. IT IS NOT POSSIBLE TO DEACTIVATE THE DUCTING
MOTOR. DO NOT COVER OR CLOSE DUCTING!
ADDITIONAL THERMOSTAT FUNCTIONING FOR DUCTING MOTOR CONTROL
For models with ducting motor there is also the possibility of thermostatting the motor itself. The connection of an external thermostat will
allow to control the ducting motor independently from stove functioning.
At this point just set the desired temperature on the thermostat. The thermostat will control the functioning of the second motor:
with temperature to be reached (closed contact) the second motor will follow the trend of the stove.
when the temperature has been reached (open contact), it takes the ducting motor to 1st speed and will be displayed by the ashing
LED relative to the ducting motor.
The ducting thermostat clamp is tted with jumper as per standard.
10
11ENGLISH
PELLETS AND FEEDING
Pellets are made by applying high pressure to sawdust, or wood waste products (not containing paint) from sawmills, carpentry and other
activities related to processing and working with wood.
Given that it does not use any glue to hold it together this type of fuel is completely environmentally friendly. In fact the compactness of the
pellets over time is guaranteed by a natural substance found in the wood itself: wood coal. In addition to being an environmentally friendly
fuel in that it pushes wood residues to the limits pellets also have technical advantages.
While wood has a caloric value of 4.4kWh/kg. (with 15% humidity after around 18 months of seasoning) the caloric value of pellets is 5 kWh/
kg.
Pellet density is 650kg/m3 and the water content is equal to 8% of its weight. For this reason they do not require seasoning in order to arrive
at a suciently adequate degree of heat yield.
THE USE OF EXPIRED PELLETS OR ANY OTHER MATERIAL WILL AFFECT THE FUNCTIONALITY OF YOUR
GENERATOR AND MAY LEAD TO THE TERMINATION OF THE WARRANTY AND CESSATION OF ANY ACCOMPANYING
RESPONSIBILITY ON THE PART OF THE MANUFACTURER
The pellets used must comply with the characteristics described by
the following standards:
EN PLUS class A1, ISO 17225-2 class A1
and
UNI EN 3035 with the following characteristics: water content
12%, ash content 0.5% and lower caloric value >17 MJ/kg (in the
case of boilers).
The manufacturer always recommended using pellets with a diameter
of 6 mm with its products.
PELLET STORAGE
In order to ensure problem-free combustion pellets must be stored in
a dry place.
Open the tank lid and load the pellets using a scoop.
12 ENGLISH
The Display DescripTion of conTrols anD symbols
ON/OFF
BUTTON
DISPLAY OF VARIOUS
TEXT MESSAGES
DISPLAY
OF POWER
TEMPERATURE SETTING OPERATION POWER ADJUSTMENT
Display icons key
Indicates the presence of an alarm.
On: indicates the presence of an alarm
O: indicates the absence of alarms
Flashing: indicates the deactivation of the depression
sensor.
It indicates weekly programming operation
Indicator on = weekly programming active
Indicator o = weekly programming not active
Indicates the room temperature status
O = the T° read by the probe is over the set temperature
set
On = the T° read by the probe is below the set temperature
indicates the stby function
O = stby deactivated
On = stby activated
Ign-plug
O = ign-plug active
On = ign-plug deactivated
Flashing = ignition phase
Not used
It indicates functioning of the fumes motor
O = fumes motor not working
On = fumes motor working
Flashing = breakdown
it indicates the communication between remote control
and stove. Every time a key is pressed on the remote
control the indicator must switch on. if the indicator is
always on it indicates that the communication between
remote control and stove is blocked.*
1
it indicates functioning of the tangential fan
O = not working
On = working
Flashing = The motor is operating in COMFORT momde
(where present)
Not used
2
Not used
Additional ducted thermostat input status:
On: closed contact (to be reached)
Flashing: the motor is running at minimum, in modulation
mode (input=open)
It indicates the operation of the pellet feed motor.
O = pellet feed motor deactivated
On = pellet feed motor active.
13ENGLISH
Do noT Use any inflammable liQUiDs for iGniTion!
Do noT alloW The baG of pelleTs To come inTo conTacT WiTh The boilinG hoT sToVe DUrinG The fillinG phase!
in The eVenT of conTinUoUs no iGniTion, conTacT an aUThoriseD Technician.
iT is forbiDDen To Use The appliance WiThoUT The DiViDer anD/or
Glass proTecTion (see fiGUre aT The siTe) jeoparDises The safeTy of
The proDUcT anD leaDs To The immeDiaTe VoiDinG of The WarranTy
perioD. in The case of Wear or DeTerioraTion reQUesT afTer-sales
assisTance for replacemenT of The parT (replacemenT ThaT is noT
UnDer GUaranTee as The componenT is sUbjecT To Wear).
To access the menu, keep key 5 pressed for a few seconds.
menU sTrUcTUre
Key 1 to conrm parameter/
programming and exit.
Keys 2 and 3 to set data/parameters.
Keys 4 and 5 to go forward or backward
in the menu.
3
3
3
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
year
2  3
monTh
2  3
DaTe
2  3
minUTes
2  3
hoUrs
2  3
Day
2  3
enable chrono
PROG. 1 - 2
ON/OFF
sTop proG 2
2  3
mon - fri
2  3
sTop proG 1
2  3
sTarT proG 1
2  3
sTarT proG 2
2  3
easy seTUp
sTanD by
2  3
reseT
2  3
CONFIRM
WITH KEY 1
iT, en, fr, De, es,pT
2  3
seT chrono
lanGUaGe
User
mon - fri
2  3
*enable chrono
seT clock
5
* Where present – certain models.
When “ENABLE CHRONO” is not included in the menu, enabling is done directly in SET CHRONO.
General WarninGs
Advice to follow for the rst start-ups of the product:
During the rst hours of operation, there may be some smoke or
odours, but they are due to the normal “thermal break-in process.
During this process, the duration of which changes depending on
the product, it is recommended to:
Ventilate the room well
If present, remove any majolica parts from the top of the
product
Activate the product at the maximum power and temperature
Avoid remaining in the room for a long time
Do not touch the surfaces of the product
Notes:
The process is completed after a few heating/cooling cycles.
Do not use for the combustion of elements or substances other than
those indicated in the manual.
Before turning on the product, it is necessary to perform the
following checks:
If it is intended to be connected to a hydraulic system, it must
be complete and fully functional and in compliance with the
instructions given in the product manual and with the relevant
regulations in force.
The pellet hopper must be completed loaded
The combustion chamber and the burn pot must be clean
Make sure that the re holder, the ash pan and the pellet
hopper close hermetically (if present in the hermetic version); they
must be closed and there must be no foreign bodies in the sealing
elements and gaskets.
Check that the power cord is properly connected
The bipolar switch (if present) must be set to position “1”.


Produkt Specifikationer

Mærke: La Nordica
Kategori: Komfur
Model: Giusy Evo

Har du brug for hjælp?

Hvis du har brug for hjælp til La Nordica Giusy Evo stil et spørgsmål nedenfor, og andre brugere vil svare dig