Master MH-400T-KFA Manual

Master Varmeapparat MH-400T-KFA

Læs gratis den danske manual til Master MH-400T-KFA (15 sider) i kategorien Varmeapparat. Denne vejledning er vurderet som hjælpsom af 36 personer og har en gennemsnitlig bedømmelse på 4.5 stjerner ud af 18.5 anmeldelser. Har du et spørgsmål om Master MH-400T-KFA, eller vil du spørge andre brugere om produktet?

Side 1/15
Model Number
MH-400T-KFA
CONSUMER: READ AND SAVE THESE INSTRUCTIONS
GENERAL HAZARD WARNING: Be sure to comply with the
instructions and warnings provided with this heater, or death,
serious bodily injury and property loss, damage from the hazards
of fire, explosion, burn,asphyxiation, and carbon monoxide poisoning can result.
Only persons who can follow and understand these instructions should use or service this
heater. If you need heater information such as an instruction manual, labels, etcetera,
contact the manufacturer.
DANGER
Sauk Rapids, MN 56379 USA • Toll Free (800) 641-6996
Fax: 320-251-2922 • Web: www.masterindustrialproducts.com • Email: info@pinnacleclimate.com
© 2020 Pinnacle Climate Technologies, Inc. MAKE-409
Users Manual &
Operating Instructions
KEROSENE FORCED AIR
HEATER
IMPORTANT: Read and understand all of the directions in this manual before assembling,
starting, or servicing the heater. Improper use of this heater can cause serious injury. Keep
this manual for future reference. The requirements of local authorities having jurisdiction
shall be followed.
Not for use in residential living areas or in non-adequately
ventilated enclosed spaces. Suitable for outdoor use. Indoor use
permitted for: The temporary heating of adequately ventilated
buildings or structures under construction, alteration or repair.
DANGER
NEVER LEAVE HEATER UNATTENDED WHILE BURNING
OR WHILE CONNECTED TO A POWER SOURCE
© 2020, Pinnacle Climate Technologies, Inc. Kerosene Forced Air Heater User’s Manual
2
This is a kerosene direct-red, forced air heater. Kerosene forced
air heaters are primarily intended for use for temporary heating
of buildings under construction, alteration or repair. Direct-red
means that all of the combustion products of the heater enter the
heated space. This appliance is rated at 98% combustion efciency,
but does produce small amounts of carbon monoxide. Carbon
monoxide is toxic.
Humans can tolerate small amounts of carbon monoxide, and
precautions should be taken to provide proper ventilation. Failure
to provide proper ventilation according to this manual can result
in death. Early signs of carbon monoxide poisoning resemble the
u. Symptoms of improper ventilation are: Symptoms of improper
ventilation / carbon monoxide poisoning are:
Headache • Dizziness • Nausea Dry Mouth Sore Throat •
Burning of Nose and Eyes
For optimal performance of this heater, it is strongly suggested
that K-1 kerosene be used. K-1 kerosene has been refined to
virtually eliminate contaminants, such as sulfur, which can cause
a rotten egg odor during the operation of the heater. Diesel may
also be used if K-1 kerosene is not available. Be advised that
diesel does not burn as clean as K-1 kerosene, and care should
be taken to provide more fresh air ventilation to accommodate any
added contaminants that may be added to the heated space. Use
of diesel may result in more periodic maintenance.
- CSA certified for use with K-1 kerosene, no. 1 & no. 2 diesel,
JP8/Jet A Fuel
Risk of indoor air pollution!
- Use this heater only in well ventilated areas! Provide, at heater
level, at least a three square foot (2,800 sq. cm) opening of
outside air for every 100,000 BTU/hr of heater rating.
- People with breathing problems should consult a physician
before using the heater.
- Carbon Monoxide Poisoning: Early signs of carbon monoxide
poisoning resemble flu-like symptoms such as headaches,
dizziness, and/or nausea. If you have these symptoms, your
heater may not be working properly.
- Get fresh air at once! Have the heater serviced. Some people
are more affected by carbon monoxide than others. These include
pregnant women, those with heart or lung problems, anemia, or
those under the influence of alcohol, or at high altitudes.
Risk of burns / fire / explosion!
- NEVER use fuels such as gasoline, benzene, paint thinners,
crankcase drainings, or other oil compounds in this heater (RISK
OF FIRE OR EXPLOSION).
MASSACHUSETTS RESIDENTS: Massachusetts
state law prohibits the use of this heater in any building which
is used in whole or in part for human habitation. Use of this
heating device in Massachusetts requires local fire department
permit (M.G.L.C. 148, Section 10A).
NEW YORK CITY RESIDENTS: The New York City
Fire Code prohibits the storage, handling and use of kerosene
fueled heaters for space heating. Any person violating that
provision may be punished by a fine up to $10,000 and a term
of imprisonment of up to 6 months.
WARNING: This product can expose you to chemicals,
including lead, which is known to the State of California to
cause birth defects or other reproductive harm. For more
information visit www.p65warnings.ca.gov
Table of Contents
Safety Information ......................................................................2-3
Features 3 ........................................................................................
Specifications 4 ................................................................................
Unpacking...................................................................................... 5
Assembly 5-6 ....................................................................................
Operation 6-8 ....................................................................................
Maintenance 9-11 .............................................................................
Wiring Diagram ............................................................................ 11
Exploded View ............................................................................. 12
Parts List ..................................................................................... 13
Troubleshooting Guide ................................................................ 14
Warranty 15 ......................................................................................
FIRE, BURN, INHALATION AND
EXPLOSION HAZARD. Keep com-
bustibles such as building materials,
paper or cardboard a safe distance away from the heater as
recommended by these instructions. Never use the heater in
spaces which contain products such as gasoline, solvents, paint
thinners, dust particles, volatile or airborne combustibles or any
unknown chemicals. This is an unvented portable heater. It
uses air (Oxygen) from the area in which it is used. Adequate
combustion and ventilation air must be provided. Refer to
“Ventilation” on page 7.
WARNING
DO NOT OPERATE THIS HEATER
UNTIL YOU HAVE READ AND
THOROUGHLY UNDERSTAND
THESE SAFETY AND OPERATING INSTRUCTIONS. Failure
to comply with the precautions and instructions provided with
this heater can result in death, serious bodily injury, property
loss or damage from the hazards of fire, soot production, explo-
sions, burns, asphyxiation or carbon monoxide poisoning. Only
persons who can read and understand these instructions should
use or service this heater.
WARNING
Safety Information
Indicates an imminently hazardous
situation which, if not avoided, WILL
result in death or serious injury.
Indicates a potentially hazardous situa-
tion which, if not avoided, COULD result
in death or serious injury.
Indicates a potentially hazardous
situation which, if not avoided, MAY
result in minor or moderate injury.
WARNING
DANGER
CAUTION
CARBON MONOXIDE POISONING MAY
LEAD TO DEATH!
DANGER
WARNING
WARNING


Produkt Specifikationer

Mærke: Master
Kategori: Varmeapparat
Model: MH-400T-KFA

Har du brug for hjælp?

Hvis du har brug for hjælp til Master MH-400T-KFA stil et spørgsmål nedenfor, og andre brugere vil svare dig




Varmeapparat Master Manualer

Master

Master 215TMHD-KFA Manual

10 Januar 2025
Master

Master BV 500 Manual

18 Oktober 2024
Master

Master MH-400T-KFA Manual

7 September 2024
Master

Master MH-05-240-GH Manual

7 September 2024
Master

Master MH-80TBOA-OFR Manual

7 September 2024
Master

Master MH-53-240 Manual

7 September 2024
Master

Master 190TMHD-KFA Manual

6 September 2024
Master

Master MH-80TBOA-KFA Manual

6 September 2024
Master

Master 140TMHD-KFA Manual

6 September 2024
Master

Master 150VMHD-GFA Manual

6 September 2024

Varmeapparat Manualer

Nyeste Varmeapparat Manualer

Lavex

Lavex 761AMLV75 Manual

15 Juni 2025
XPower

XPower A-12 Manual

15 Juni 2025
BEKO

BEKO RHO8323BT Manual

14 Juni 2025
XPower

XPower B-55 Manual

14 Juni 2025
XPower

XPower B-2 Manual

14 Juni 2025
XPower

XPower M-27 Manual

14 Juni 2025