Læs gratis den danske manual til Planet MC-1500R (4 sider) i kategorien Ikke kategoriseret. Denne vejledning er vurderet som hjælpsom af 16 personer og har en gennemsnitlig bedømmelse på 4.5 stjerner ud af 8.5 anmeldelser. Har du et spørgsmål om Planet MC-1500R, eller vil du spørge andre brugere om produktet?

Side 1/4
- 1 -
- 2 -
- 3 -
- 4 -
- 5 -
- 6 -
- 7 -
- 8 -
1. Package Contents
Before start installing the Converter, verify the package
contains the following parts:
 TheMediaConverterChassisx1
 User'sManualx1
 MountingAccessory(for10/19”ChassisShelf)x1
 RubberFeetx4
 ACPowerCordx1
Ifanyofthesearemissingordamaged,pleasecontactyour
dealer immediately, if possible, retain the carton including
the original packing material, and use them against to
repacktheproductincasethereisaneedtoreturnittous
for repair.
3. Media Converter Chassis
Front Panel
Figure 3-1 & 3-2 & 3-3 shows a front panel of MC-700 /
MC-1500/MC-1500R/MC-1500R48.
Figure 3-1 MC-700 Front Panel
Figure 3-2 MC-1500 Front Panel
Figure 3-3 MC-1500R / 1500R48 Front Panel
6. Installing the Media Converter
Chassis
6.1 Installing Media Converter Chassis to
10/19-inch Wiring Closet Rack
» Installfourscrewsthroughmountingearsintoeachside.
» Locate Converter Chassis at 10/19-inch mounting rails
andscrewupthefrontbrackets.
» Set Main power switch at OFF” position before
connectingthepowercord.
Figure 6-1 InstallingMediaChassisinWiringClosetRails
5. Media Converter Chassis
Rear Panel
Figure 5-1 & 5-2 & 5-3 shows a rear panel of MC-700 /
MC-1500/MC-1500R/MC-1500R48.
The rear panel of the MC-700 is with one fan, one ON/
OFF Switch and a power inlet that accept 100~240V AC,
50/60Hzpowerinput.
Figure 5-1 MC-700 Rear Panel
The rear panel of the MC-1500 is with two fans, one ON/
OFF Switch and a power inlet that accept 100~240V AC,
50/60Hzpowerinput.
Figure 5-2 MC-1500 Rear Panel
2. Product Features
 Highquality10"
/
19”Rack-MountableChassisinstallation
● Supports up to seven (7) / fteen (15) hot-swappable
mediaconverters
● One fan brings the air-ow for system cooling, and LED
indicatorsforsystemandfanstatus(MC-700)
● Two fan brings the air-ow for system cooling, and LED
indicatorsfor systemandfanstatus(MC-1500 /1500R/
1500R48)
● Thepowerslotatrearpanelforredundantpowersupport
with options of 100~240V AC or -48V DC supplies
(MC-1500R/1500R48)
● Bay power isolation, ensure each bay is electrically
isolatedfromeachother
Support multiple converters with 10/100/1000Mbps,
copper,Fiber,single/multi-modeST/SC/SFPconnectors
Reducetheeffort ofconvertermaintenance andmanage-
ment,diagnosethestatusatonetime
 Cost-effective,easyinstall
4. LED Indicators
MC-700
Printing LED
Status Description
PWR
ON Thechassisispowered.
OFF
Thechassisisnotpoweredorpower
failure,iftheACoutletiswith
100~240VACvoltage.Pleaseconsult
yourlocaldealerifpowerfailure.
FAN
ON Thefanisfunctionalok.
OFF
Thefanisnotpoweredoritis
malfunction.IfthefanLEDremains
offwhilepowerison.Pleaseconsult
yourlocaldealertoreplacetheFAN.
MC-1500 Series
Printing LED
Status Description
PWR
ON Thechassisispowered.
OFF Thechassisisnotpoweredorpower
failure.
FANA/
FANB
ON ThefanisfunctionalO.K.
OFF
Thefanisnotpoweredoritis
malfunction.IfthefanLEDremains
offwhilepowerison.Pleaseconsult
yourlocaldealertoreplacetheFAN.
TherearpaneloftheMC-1500R/1500R48.
Figure 5-3 MC-1500R / 1500R48 Rear Panel
Note
1.TheMC-1500Rshippedwithone100~240V
ACpowersupplymodule(MC-15RPS130).
2.TheMC-1500R48shippedwithoneDC-48V
powersupplymodule(MC-15RPS48).
Power
Notice
1.Thedeviceisapower-requireddevice,it
means,itwillnotworktillitispowered.
Ifyournetworksshouldactiveallthe
time,pleaseconsideruseaproperUPS
(UninterruptedPowerSupply)foryour
device.Itwillpreventyoufromnetwork
datalossornetworkdowntime.
2.Insomearea,installingasurge
suppressiondevicemayalsohelpto
protectyourchassisfrombeingdamaged
byunregulatedsurgeorcurrenttothe
converterorthepoweradapter.
Rack Mount Instructions
A) Elevated Operating Ambient - If installed in a closed or
multi-unitrackassembly,theoperatingambienttemper-
ature of the rack environment may be greater than
room ambient.Therefore,considerationshouldbegiven
to installing the equipment in an environment compat-
ible with the maximum ambient temperature (Tma)
speciedbythemanufacturer.
B) Reduced Air Flow - Installation of the equipment in a
rackshouldbesuchthattheamountofairowrequired
forsafeoperationoftheequipmentisnotcompromised.
C) Mechanical Loading - Mounting of the equipment in the
rack should be such that a hazardous condition is not
achievedduetounevenmechanicalloading.
D) Circuit Overloading - Consideration should be given to
the connection of the equipment to the supply circuit
andtheeffectthatoverloadingofthecircuitsmighthave
onovercurrentprotectionandsupplywiring.Appropriate
considerationofequipmentnameplateratings shouldbe
usedwhenaddressingthisconcern.
E) Reliable Earthing - Reliable earthing of rack-mounted
equipment should be maintained. Particular attention
should be given to supply connections otherthan direct
connections to the branch circuit (e.g. use of power
strips)."


Produkt Specifikationer

Mærke: Planet
Kategori: Ikke kategoriseret
Model: MC-1500R

Har du brug for hjælp?

Hvis du har brug for hjælp til Planet MC-1500R stil et spørgsmål nedenfor, og andre brugere vil svare dig