Prima LIA110 Manual

Prima Emhætte LIA110

Læs gratis den danske manual til Prima LIA110 (2 sider) i kategorien Emhætte. Denne vejledning er vurderet som hjælpsom af 2 personer og har en gennemsnitlig bedømmelse på 4.8 stjerner ud af 1.5 anmeldelser. Har du et spørgsmål om Prima LIA110, eller vil du spørge andre brugere om produktet?

Side 1/2
GENERAL INSTRUCTIONS
WARNING AND SAFETY INSTRUCTIONS
1. Before installation and before using the Cooker Hood for the rst time read the Operating
Instructions carefully. This way you will avoid the risk of accidents and damage to the
appliance.
2. The Cooker Hood must only be used for domestic household purposes.
3. Children should not be allowed to play with the Cooker Hood or tamper with the controls.
Please supervise its use by the elderly or the infirm.
5. It is dangerous to alter the specications or modify the product in any way.
6. Repairs should only be carried out by an authorised engineer.
safety regulations.
8. Do not use the Cooker Hood without the grease lter in place.
9. When the Hood is fitted for EXTERNAL EXTRACTION the ducting must NOT be connected
to a ue which is used for exhausting fumes from appliance supplied with energy other
than electric such as a central heating ue or water heating ue. If the room in which the
Cooker Hood is to be used contains a fuel burning appliance such as a central heating
boiler then its ue must be of the room sealed or balanced ue type. If other types of ue
or appliances are tted special care must be taken to ensure that there is an adequate
supply of air to the room. This is because using the Cooker Hood at the same time as
another heating appliance which depends on the air in the room (i.e. gas, oil or coal fired
heaters etc.,) extracts the air which these types of heaters need for combustion. All
installations must comply with the local authorities requirements for the discharge of exhaust
air.
10. When the Cooker Hood is connected for INTERNAL RECIRCULATION with a Charcoal
Filter fitted the Cooker Hood can be used without any ventilation restrictions.
NOTE:
Charcoal Filters cannot be washed. They must be replaced, depending upon use, every 4-
6 months.
grill assembly or before any type of maintenance work.
12. Do keep heated areas of the hob covered over with pots and pans when using the hob and
Cooker Hood at the same time.
GENERAL
Before tting the hood, make sure that the voltage indicated on the rating plate corresponds to
the mains voltage in your home.
This product has been designed to be used as an EXTERNAL EXHAUSTING Cooker Hood
but may also be installed for recirculation (WITH THE ADDITION OF A CHARCOAL FILTER).
RATING PLATE
number, colour.
If you ever need to call a service engineer you must quote model number and colour.
TECHNICAL INFORMATION
Mains voltage 230 V 5O HZ
Motor 125W
ELECTRICAL CONNECTION
IMPORTANT:
ENSURE THAT THE ELECTRICITY SUPPLY IS SWITCHED OFF BEFORE CONNECTING.
POLE SWITCHED FUSED SPUR OUTLET.
the N.I.C.E.I.C. and who will comply with the I.E.E. and local regulations.
WARNING: THIS APPLIANCE MUST NOT BE EARTHED.
DO NOT CONNECT EITHER WIRE TO THE EARTH TERMINAL. THE WIRES IN THE MAINS
LEAD ARE COLOURED IN ACCORDANCE WITH THE FOLLOWING CODE:
BLUE = NEUTRAL, BROWN = LIVE
Should the colours of the wires in the mains lead for the appliance not correspond with the
FUSE
ON
DOUBLE POLE
SWITCHED FUSED
SPUR OUTLET
USE A
3 AMP FUSE
coloured markings identifying the terminal in your spur box proceed as follows:
(1) The wire which is coloured blue must be connected to the terminal marked N (Neutral) or
coloured Black.
(2) The wire which is coloured brown must be connected to the terminal marked L (Live) or
coloured Red.
INSTALLATION-WARNING
Whether installed for external exhausting or for internal recirculation the Cooker Hood should
be placed at the correct height over a hob, as the heat generated may activate the Motor
Protection circuit which will switch the hood o, or even cause the hood to catch re.
Height above gas hob - 750mm. minimum.
Height above electric hob - 650mm. minimum.
Never place the Cooker Hood over an eye -level grill.
must be in accordance with tha Gas Safety (Installation & Use) Regulations 1984 and the
relevant Building Regulations. Detailed recommendations are contained in the following British
Standard Codes of Practice BS6172, BS5440 and BS6891 Current Edition.
SAFETY
A) Never leave a frying pan unattended during use as overheated fats and oils may catch fire.
B) To avoid the risk of re cleaning of lter should be regularly carried out in accordance with
instructions, as clogging of fat on the synthetic lter can give rise to a re hazard.
C) Do not prepare ambees or use ames under the Cooker Hood. NOTE that damage so
caused by this or any other as a result of failure to clean the filter could make the guarantee
void.
COOKER HOOD NOT WORKING
A) Check other electrical appliances nearby - in case there is a power failure.
B) Check plug/fuse (s).
suspect an electrical fault.
D) Has the hood become too hot and switched off?
E) If the hood still does not function - contact the Dealer from whom you purchased the
product with details of the fault who will make arrangements for repair or replacement..
THIS PRODUCT IS MANUFACTURED IN ITALY
The manufacturer reserves the right to alter specications without notice.
PROOF OF PURCHASE
You will be required to produce your receipt should any request for service be made. We
suggest you attach it to this page, and keep this booklet in a safe place.
GUARANTEE
This product carries a 12 month Guarantee to cover against faulty workmanship of material
used in manufacture, provided such a defect appears in the product within 12 months from the
date of sale to the original purchaser. Please keep this booklet in a safe place. You will be
asked to produce it if you request a service under this Guarantee. You should also be prepared
to produce your receipt.
SERVICE
When you ring service the following information will be required, and it will be helpful if these
details are available before you call as it will assist the service sta to deal with your request
as quickly as possible.
A) Your name, address and postcode.
B) Your telephone number.
C) Model number and colour.
D) Date of purchase.
E) Clear and concise details of the fault.
CONDITIONS
a. The unit must be correctly installed and operated in accordance with the
manufacturers instructions and used for normal domestic purposes in England,
mainland Scotland or Wales.
b. The guarantee does not cover accidental damage, misuse or alterations which are
likely to aect these units.
c. The guarantee is invalid if the product is resold, installed by, tampered with or repaired
by any unauthorised person.
d. The guarantee in no way aects your statutory rights.
This appliance complies with the EEC directives EMC 89/336/EEC revised 92/31/EEC and
93/68/EEC.
EXTERNAL EXHAUSTING-GENERAL INFORMATION
of these two may be used depending on the limitations imposed by the existing kitchen tments.
The appliance is normally supplied with the top outlet open and provided with a connecting ring
C (see fig.1) onto which the external exhausting venting pipe, which should have an inner diameter
of 120 mm, must be tted (not supplied). The rear air outlet is sealed by means of a blanking plug
A (See g.1). If is intended to use the rear outlet, instead of the top outlet, the following easy
changes must be made to the appliance:
A) Remove the blanking plug A at the rear by gently easing it out with a screwdriver.
B) Then t the blanking plug into the top outlet hole after rst removing the connecting ring C.
C) Fit the connecting ring C to the rear outlet.
CHANGING THE COOKER HOOD FROM EXTERNAL EXHA O INTERNALUSTING T
RECIRCULATION
If it is intended to use the Cooker Hood for internal recirculation it will be necessary to obtain from
the dealer a charcoal lter which will trap odours and purify the air. (Depending on use, it will be
necessary to replace the charcoal lter every 4-6 months). The following changes now need to be
made:
A) Seal the top and rear air outlets with the blanking plugs.
B) Open and hinge down the grill G (see g.2).
C) Move the small lever Z from position A to position F (see fig.2).
D) Place the charcoal filter on the centre of the motor support, and when firmly located turn it 90°
(
1
/4 of a turn) until the STOP click is heard to lock it into position. (When you need to remove
the charcoal lter turn it in the opposite direction).
INSTALLATION-EXTERNAL EXHAUSTING
A) After deciding which air outlet to use ensure other air outlet sealed - as previously instructed.
B) Fit connecting ring C (see g. 1) to the hole and couple it to the venting pipe (which must have
an inner diameter of 120 mm).
C) Ensure that the venting pipe is inclined at least 10° upwards to assist in the fume exhaustion,
and have no more than two 90° bends in its total run.
(NOTE:- Ensure connecting ring is correctly inserted through the outlet hole and coupled to the
venting pipe).
manufacturer.
SAFETY WARNING:
Under no circumstances should you vent the hood through that of other appliances.
INSTALLATION ON A WALL
650 mm. from the cooking surface to the lowest part of the hood). The hood may now be hung on
the wall inserting the screws in the rear holes Z (see g. 1) then rmly support the hood by
screwing in through rear holes Y (see g. 1).
INSTALLATION UNDER A CUPBOARD
A) Drill 4 holes of 6 mm diameter in the bottom of the cupboard at the positions shown (see g.
1) and one hole of 10 mm diameter for the mains lead.
B) If the Cooker Hood is to be used for external exhausting with the air outlet at the top then a
hole of 130 mm should be cut in the cupboard to allow for the outlet pipe.
C) Fix the hood beneath the cupboard by using 4 screws and washers.
USING THE COOKER HOOD
It is advisable to switch the Cooker Hood on a few minutes before cooking starts and that it be left
on for about 15 minutes after cooking is completed in order to exhaust all the odours. On the front
of the hood there are:- A) An on/o switch for the light. B) A switch to adjust the working speed. C)
Cooker Hood ON indicator light.
IMPORTANT
Flames could damage the lters so ensure that they do not come in contact with the hood.
MAINTENANCE
A) Before carrying out any sort of maintenance disconnect the hood from the mains supply.
B) Release and hinge down the grill G (See g.2).
C) Remove the grease filter fixing clamps
D) Carefully extract the synthetic grease filter which should then be washed by hand in lukewarm
water and liquid detergent at least once a fortnight.
When clean squeeze gently but do not wring it out. Before replacing the synthetic grease lter
clean the lter holder in a warm detergent solution or with a damp cloth. Then replace the
synthetic grease filter when dry.
E) The inside and outside of the hood may also be cleaned with a damp cloth and/or warm
sudsy water.
note: NEVER USE ABRASIVES!
F) The hood must not be used without the grease filter.
CHARCOAL FILTER-INTERNAL RECIRCULATION ONLY
Charcoal filters cannot be washed. They must be replaced, depending upon use, every 4-6 months.
A) Disconnect the hood from the mains.
B) Release and hinge down the grill G (See Fig. 2).
C) Twist off charcoal filter from centre of motor support and replace with new charcoal filter - see
instructions under changing the Cooker Hood from e nal exhausting to internal recirculation.xter
D) Reassemble.
GUARANTEE
A) Switch o the light switch on the front of the Cooker Hood.
B) Disconnect the hood from the mains supplly.
C) Release and hinge down grill G to gain access to light bulb.
D) Replace bulb (40 watt screw).
E) Ret grill.
F) Reconnect the hood to mains supply and switch ON Cooker Hood light.
520
480
37
Z
Y
A
Y
Z
205
23
21
150
C
Fig. 1
Fig. 2
Z
X
A
F
C
G
Fig. 3
45
45
256
240
224
480
500-600
458-558 45
150
37
150
520
480
54
ø120
ø120
80
STANDARD CONVENTIONAL COOKER HOOD
EXTERNAL EXHAUSTING
Insert the connecting ring B (see Fig.1) through hole A (see Fig.1) on to which the
external exhausting Venting pipe, which must have an inner diameter of 120mm,
must be tted (Venting kit not supplied).
According to the positioning, the pipe, having no more than two 90° bends in the
entire run, is then directed to the most convenient outside wall or through the ceiling.
IMPORTANT - When fitting Venting kits please follow assembly instructions provided
by the Venting kit manufacturers.
SAFETY WARNING - Under no circumstances should the hood be vented through
that of other appliances.
INTERNAL RECIRCULATION
If it is intended to use the hood for internal recirculation it will be necessary to
obtain from the dealer a charcoal lter which will trap the odours and purify the air.
(Depending upon use, it will be necessary to change the charcoal lter at least
once every 4-6 months).
NOTE: The charcoal lter cannot be washed or regenerated.
PROCEED AS FOLLOWS:
A-
Take hold of knob Y and carefully lift the grill up and out of the groove behind
which it is retained. The grill is then free to remove by carefully pulling down and
out of the Hood (see Fig. 2).
B-
Place the charcoal lter on the centre of the motor support and when rmly
located turn it 90° (
1
/4 of a turn) until the click is heard to lock it in« »STOP
position.
C-
Carefully replace the grill.
FIXING THE FRONT PANEL
A-
It is necessary rst to remove Grill (see Fig. 2) by taking hold of knob Y and
carefully lifting the Grill up and out of groove behind which it is retained. The
Grill is then completely free to remove by carefully pulling down and out of the
Hood.
B-
Remove sloping door front E (Fig. 4) by pulling inwards the plastic stops
connected to the special spring locking knobs H (Fig. 4) until the door is eased
forward out of its side retaining channels.
C-
Drill holes through sloping door front as indicated (see Fig. 5) then screw cabinet
door to front of hood door with screws provided.
D-
Replace completed door by rst inserting it into upper slides and then pulling
the plastic stops on the spring locking knob H to allow entry into lower side
retaining channels and push until locking occurs.
E-
Carefully replace the Grill.
FITTING THE HOOD BETWEEN CUPBOARDS ON EITHER SIDE (See Fig. 6)
There are two holes on either side of the cooker hood. To gain access rst remove
grill and sloping door front. This will allow for correct position of cooker hood against
cupboards on either side. Mark positions for the screws, remove cooker hood, drill
2 holes on each side where marked.
Should the cupboards not be considered strong enough angle frame L (Fig. 2) can
positioning of hood, screw angle frame L to wall, replace hood and screw into
B
A
M
C
E
H
T
A
G
B
C
Y
G
L
P
E
1
3
4
75
205
100
6
60
120
120
46
5
46
7
0 120
65
270
8
35
349
16
38,5
349
38,5
35
16
48,5 48,5
502
522
599
2
INTEGRATED COOKER HOOD
3LIK0202 - - 47/05 3LIK020230
INSTALLATION AND OPERATING
INSTRUCTIONS
FOR
STANDARD (CONVENTIONAL)
INTEGRATED
AND
CANOPY HOODS
FITTING THE CANOPY HOOD (See Fig. 3)
1. Check the size of the cut-out in the cupboard with the measurements given in Fig.
3.
hood.
3. Locate the canopy hood carefully into the aperture and using 4 woodscrews, screw
the hood rmly into position.
EXTERNAL EXHAUSTING (See Fig. 1)
Connect the external exhausting venting pipe, which must have an inner diameter of
120 mm to the coupling flange B (See Fig. 3). ( VENTING KIT NOT SUPPLIED).NOTE:
According to the positioning, the pipe is then directed to the most convenient outside
wall, or through the ceiling, having no more than two 90 bends in the entire run.°
IMPORTANT - When tting venting kits please follow assembly instructions provided
by venting kit manufacturers.
SAFETY WARNING - Under no circumstances should the hood be vented through that
of other appliances.
INTERNAL RECIRCULATION (See Fig. 2)
If it is intended to use the hood for internal recirculation it will be necessary to obtain
from the dealer a charcoal lter which will trap the odours and purify the air.
(Depending upon use, it will be necessary to change the charcoal lter at least once
every 4-6 months).
NOTE: The charcoal lter cannot be washed or regenerated. (see Fig.4)
PROCEED AS FOLLOWS:
a) Unfasten slide brackets either side of grill G and hinge grill down (see Fig.4).
b) Place the charcoal lter on the centre of the motor support and when rmly located
turn clockwise 90° (
1
/4 of a turn) until the click is heard to lock it in position.« »STOP
c) Carefully reassemble grill and close slide brackets either side of grill G (Fig.4).
USING THE COOKER HOOD
It is advisable to switch the cooker hood on a few minutes before cooking starts and
the odours.
On the inner left side of the hood will be found:
a) Light switch - for ON/OFF control.
b) Exhaust fan speed control switch - 3 speed and OFF .
c) Cooker hood ON indicator RED light.
IMPORTANT
Flames will damage the lters so ensure that they do not come in contact with the
hood.
MAINTENANCE
a) Before carrying out any sort of maintenance disconnect the hood from the mains
supply.
b) Unfasten slide brackets either side of grill and hinge grill down (see Fig.4).
c) Remove the grease filter fixing clamp.
d) Carefully extract the synthetic grease lter which should then be washed by hand in
lukewarm water and liquid detergent at least once a fortnight. When clean squeeze
gently but do not wring it out. Before replacing the synthetic grease lter clean the
lter holder in a warm detergent solution or with a damp cloth. Then replace the
synthetic grease lter when dry.
e) The inside and outside of the hood may also be cleaned with a damp cloth and/or
warm sudsy water. NOTE: NEVER USE ABRASIVES!
f) The hood must not be used without the grease lter.
depending upon use, every 4-6 months.
REPLACING THE BULB - NOTE: BULB REPLACEMENT IS NOT COVERED BY
YOUR GUARANTEE
a) Switch off the light switch on the cooker hood.
b) Disconnect the hood from the mains supply.
c) Unfasten slide brackets either side of grill and hinge grill down (see Fig.4).
d) Replace bulb or bulbs.
e) Refit grill.
f) Reconnect the hood to mains supply, switch ON hood light.
CANOPY COOKER HOOD
cupboards as previously indicated. Then replace retaining screws that hold angle
frame L to underside of hood. Replace door front and grill.
FITTING THE HOOD TO WALL
First remove Grill (see Fig. 2) and door front E (see Fig. 4) as indicated under
FIXING THE FRONT PANEL section.
Check positioning of hood on wall, mark and drill the 6 holes required (see Fig. 8)
and screw in the two hooks T (see Fig. 8) and angle frame L (see Fig. 2) to the wall.
Adjust positions of the upper brackets M (see Fig. 1) located on the top of the hood
to engage the two hooks T. Adjustments and tightening up of the screws on upper
brackets and angle frame L allows for alignment to adjoining cupboards. Finally
replace door front and grill.
USING THE COOKER HOOD
It is advisable to switch the cooker hood on a few minutes before cooking starts
and that it be left on for about 15 minutes after cooking is completed in order to
exhaust all the odours.
On the inner left side of the hood will be found:
a) Light switch - for manual or automatic control.
b) Exhaust fan speed control switch - for manual or automatic control.
c) Cooker hood ON indicator light.
IMPORTANT
Flames will damage the lters so ensure that they do not come in contact with the
hood.
MAINTENANCE
a) Before carrying out any sort of maintenance disconnect the hood from the mains
supply.
b) It is necessary rst to remove Grill (see Fig. 2) by taking hold of knob Y and
carefully lifting the Grill up and out of groove behind which it is retained.
The grill is then completely free to remove by carefully pulling down and out of
the Hood.
c) Remove the grease filter fixing clamps.
d) Carefully extract the synthetic grease filter which should then be washed by
hand in lukewarm water and liquid detergent at least once a fortnight. When
clean squeeze gently but do not wring it out. Before replacing the synthetic
grease lter clean the lter holder in a warm detergent solution or with a damp
cloth. Then replace the synthetic grease lter when dry.
e) The inside and outside of the hood may also be cleaned with a damp cloth and/
or warm sudsy water.
NOTE: NEVER USE ABRASIVES!
f) The hood must not be used without the grease lter.
IMPORTANT REMINDER: Charcoal filters cannot be washed and should be
replaced, depending upon use, every 4-6 months.
YOUR GUARANTEE
a) Switch off the light switch on the cooker hood.
b) Disconnect the hood from the mains supply.
c) It is necessary first to remove the Grill (see Fig. 2) by taking hold of knob Y and
carefully lifting the Grill up and out of groove behind which it is retained. The
Grill is then completely free to remove by carefully pulling down and out of the
Hood.
d) Replace bulb or bulbs.
e) Refit grill.
f) Reconnect the hood to mains supply, switch ON hood light.
282
257
G
C
F
525
=
493
=
148
B
Fig.3 Fig.4
Fig.1
Fig.2
90°
EXTERNAL EXHAUSTING
CANOPY CANOPY
INTERNAL RECIRCULATION


Produkt Specifikationer

Mærke: Prima
Kategori: Emhætte
Model: LIA110

Har du brug for hjælp?

Hvis du har brug for hjælp til Prima LIA110 stil et spørgsmål nedenfor, og andre brugere vil svare dig




Emhætte Prima Manualer

Prima

Prima LXP70 Manual

25 Februar 2025
Prima

Prima LIA730 Manual

25 Februar 2025
Prima

Prima LIA729 Manual

25 Februar 2025
Prima

Prima LIA629 Manual

25 Februar 2025
Prima

Prima LIA559 Manual

25 Februar 2025
Prima

Prima LIA519 Manual

25 Februar 2025
Prima

Prima LIA176 Manual

25 Februar 2025
Prima

Prima LIA174 Manual

25 Februar 2025
Prima

Prima LIA172 Manual

25 Februar 2025
Prima

Prima LIA1715 Manual

25 Februar 2025

Emhætte Manualer

Nyeste Emhætte Manualer