Læs gratis den danske manual til Technoline WS 9250 (5 sider) i kategorien Vejrstation. Denne vejledning er vurderet som hjælpsom af 39 personer og har en gennemsnitlig bedømmelse på 4.9 stjerner ud af 20 anmeldelser. Har du et spørgsmål om Technoline WS 9250, eller vil du spørge andre brugere om produktet?

Side 1/5
WS9250 TEMPERATURE STATION WITH ICE ALERT
USER’S INSTRUCTION
Please read the instructions carefully and keep the manual well for future reference.
GETTING STARTED
Before using the main unit and transmitter:
1. Remove the battery door of the main unit and transmitter.
2. Install 2 new AA size batteries for both of the unit and transmitter, according to the polarity
information marked on the battery compartment.
3. Replace the battery door.
4. After the batteries are installed, all the segment of the LCD will be shown.
5. Press the “RESET” key at the back of the main unit first, and press the “RESET” key of the
transmitter.
6. It will receive 433 MHz signal for channel test automatically in 8 seconds. And after 5 minutes for
channel test, it will turn to RC signal reception automatically.
Note:
1. The unit can receive and display the readings from up to 3 remote transmitters.
2. Position the unit and transmitter within the effective transmission range: 50 meters in usual
circumstances.
3. In some cases, you may not receive the signal immediately, you can reset the unit and transmitter
again as described in the above section.
MAIN FEATURES
MAIN UNIT:
1. LCD display
- Display of the time, alarm time, outdoor & indoor temperature.
2. SNOOZE / LIGHT key
- Press it to turn on and keep the backlight for 5 seconds.
- When the alarm is sounding, press it to stop the current alarm and turn to snooze.
3. ALARM SET key
- Press it to display and keep the alarm time for 5 seconds. During the alarm time displayed riod, pe
press it to turn on/off alarm function.
- Press and hold it for 3 seconds to enter alarm time setting mode.
- In alarm time setting mode, press it to step the setting item, and press it to save and exit the setting
after setting the minute.
4. CH/+ k ey
- In setting mode, press it to adjust the value of the flashing digit upwards. And press it without
releasing to speed up the setting.
- In normal mode, press it to manually check the outdoor temperature from channel 1 to channel 3.
Press and hold it for 3 seconds to turn to channel auto-change mode. Press it again to return to
normal mode.
5. MEM/- key
- In setting mode, press it to adjust the value of the flashing digit downwards. And press it without
releasing to speed up the setting.
- Press it to check and keep the max/min indoor and outdoor temperature for 5 seconds.
- Press and hold it for 3 seconds to delete the max./min. temperature records.
6. DIAPLAY SET key
- In normal mode, press and hold it for 3 seconds to enter time setting mode.
- In time setting mode, press it to step the setting item, and press and hold it for 3 seconds to save and
exit the setting.
7. °C/°F slide switch
- Slide it to switch temperature unit between °C/°F.
8. SENSOR key
- Press it to manual receiving 433 MHz signal for channel test.
- During the reception test, press and hold it for 3 seconds to turn off the channel test.
9. RCC key
- Press it to manually receiving RC signal.
- During the RC reception, press and hold it for 3 seconds to turn off the reception.
10. RESET key
- In case of mal-function, press it by using a metal wire to reset all the values.
11. Battery door
TRANSMITTER:
1. LED indicator
- Flashes when the remote unit transmits a reading.
2. CHANNEL slide switch
- Assign the transmitter to Channel 1, 2 or 3.
3. RESET key
- Press it to reset the transmitter.
4. Wall-mounting holder
- Use it to support the transmitter on the wall.
5. Battery compartment
SIGNAL STRENGTH INDICATOR
The signal indicator flashing means time signals are being received. If the RC temperature station
receives signal successfully, a sync- the LCD and the unit has already time symbol “ ” appears on
received the time signal. Otherwise, the signal strength symbol will disappear from the LCD display.
Note:
You may press “RCC” key to receive the time signal manually. The receive mode will be off
automatically after 6-16 minutes. Receive mode consumes more battery power that may reduce
battery lifetime.
DAYLIGHT SAVING TIME(DST)
The temperature station has been programmed to automatically switch when daylight saving time is in
effect. Your temperature station will display “DST” on the LCD during the summer.
TIME AND CALENDAR SETTING
If the temperature station does not receive the time signal successfully, you can set the time manually.
As soon as the transmitter is received again, the temperature station will automatically synchronize
with the received time.
1. In normal mode, press and hold “DISPLAY SET key for 3 seconds until the Hour format digit
flashing.
2. Press “+” / “ ” key to- select 12/24 hour format.
3. Press “DISPLAY SET” key again to step the setting item to Hour with the Hour digit flashing.
4. Press “+” / “ ” key to adjust the value of the- flashing digit.


Produkt Specifikationer

Mærke: Technoline
Kategori: Vejrstation
Model: WS 9250
Bredde: 84 mm
Dybde: 48 mm
Højde: 100 mm
Produktfarve: Sort
Indbygget skærm: Ja
Vejrudsigt: Ingen
Batteritype: AA
Baggrundsbelysning: Ja
Ur-funktion: Ja
Alarmfunktion: Ja
Modtager dimensioner (BxDxH): 65 x 35 x 100 mm
DCF radiour: Ja
Målefunktioner: Indoor thermometer,Outdoor thermometer
Trend visning af målefunktioner: Termometer
Vejrstation, extremum data: Termometer
Min. /maks. Temperatur-hukommelse: Ja