Tripp Lite AVRX650UD Manual


Læs gratis den danske manual til Tripp Lite AVRX650UD (24 sider) i kategorien Ikke kategoriseret. Denne vejledning er vurderet som hjælpsom af 16 personer og har en gennemsnitlig bedømmelse på 4.9 stjerner ud af 8.5 anmeldelser. Har du et spørgsmål om Tripp Lite AVRX650UD, eller vil du spørge andre brugere om produktet?

Side 1/24
1
Owner’s Manual
AVRX Series UPS Systems
AVRX500UD, AVRX650UD, AVRX800UD, AVRX1000UD
(Series Numbers: AG-0541, AG-0542, AG-0543, AG-0544)
Not suitable for mobile applications.
1111 W. 35th Street, Chicago, IL 60609 USA • tripplite.com/support
Copyright © 2020 Tripp Lite. All rights reserved.
Español 7 • Русский 13 • Deutsch 19
2
SAVE THESE INSTRUCTIONS
This manual contains instructions and warnings that should be followed during the installation,
operation and storage of this product. Failure to heed these warnings may affect the warranty.
UPS Location Warnings
• Install your UPS indoors, away from excess moisture or heat, conductive contaminants, dust or direct sunlight.
For best performance, keep the indoor temperature between 0º C and 40º C.
Leave adequate space around all sides of the UPS for proper ventilation.
Only set the UPS upright on a sturdy flat surface.
UPS Connection Warnings
Connect your UPS directly to a properly grounded AC power outlet. Do not plug the UPS into itself; this will damage the
UPS.
Do not modify the UPS plug, and do not use an adapter that would eliminate the UPS ground connection.
Do not use extension cords to connect the UPS to an AC outlet.
If the UPS receives power from a motor-powered AC generator, the generator must provide clean, filtered, computer-
grade output.
The mains socket outlet that supplies the UPS should be easily accessible and located near the UPS.
Equipment Connection Warnings
Use of this equipment in life support applications where failure of this equipment can reasonably be expected to cause
the failure of the life support equipment or to significantly affect its safety or effectiveness is not recommended.
Do not connect surge protectors or extension cords to the output of your UPS. This might damage the UPS and may
affect the surge protector and UPS warranties.
Connect the UPS to an outlet that is adequately protected against excess currents, short circuits and earth faults as
part of the building installation.
Battery Warnings
Batteries can present a risk of electrical shock and burn from high short-circuit current. Observe proper precautions.
There are no user-serviceable parts inside the UPS. Do not open batteries. Do not short or bridge the battery terminals
with any object. Do not dispose of batteries in a fire. The batteries may explode. Released material is harmful to the
skin and eyes. It may be toxic. Unplug and turn off the UPS before performing battery replacement. Use tools with
insulated handles. Battery replacement should be performed only by authorized service personnel using the same
number and type of batteries (sealed lead-acid).
CAUTION, RISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE. DISPOSE OF USED
BATTERIES ACCORDING TO THE INSTRUCTIONS.
CAUTION: A battery can present a risk of electrical shock and high short circuit current. The following precautions
should be observed when working on batteries.
a) Remove watches, rings or other metal objects.
b) Use tools with insulated handles.
c) Wear rubber gloves and boots.
d) Do not lay tools or metal parts on top of batteries.
e) Disconnect the charging source prior to connecting or disconnecting battery terminals.
Important Safety Instructions


Produkt Specifikationer

Mærke: Tripp Lite
Kategori: Ikke kategoriseret
Model: AVRX650UD
Bredde: 163.1 mm
Dybde: 245.1 mm
Højde: 90.9 mm
Vægt: 4540 g
Brugervejledning: Ja
Produktfarve: Sort
Pakkevægt: 4780 g
Pakkedybde: 310.9 mm
Pakkebredde: 137.9 mm
Pakkehøjde: 236 mm
Formfaktor: Tower
Responstid: 6 ms
Opbevaringstemperatur (T-T): -15 - 45 °C
Relativ luftfugtighed ved drift (H-H): 0 - 95 %
Driftstemperatur (T-T): 0 - 40 °C
Støjniveau: 40 dB
Udgangseffekt: 375 W
Certificering: CE; ROHS
LED-indikatorer: Battery replacement,Fault,Power fail
Kabellængde: 1.5 m
Opladningstid for batteri: 8 t
Hovedkassen højde (udvendigt): 257 mm
Hovedkassens længde (udvendigt): 579.9 mm
Hovedkassens bruttovægt (udvendigt): 20030 g
Hovedkassens bredde (udvendigt): 308.9 mm
Oprindelsesland: Kina
Produkter pr. hovedkasse (udvendigt): 4 stk
Indgangsfrekvens: 50/60 Hz
Hovedkasse (udvendig) GTIN (EAN/UPC): 10037332255362
Lydalarmer: Ja
Effektivitet: 95 %
Strømstik: Type F
AC udgange, antal: 4 AC stikkontakt(er)
AC stikkontakt typer: Type F
Overspænding energivurdering: 156 J
Indgående driftsspænding (maks.): 240 V
Output strømkapacitet (VA): 0.65 kVA
Indgående driftsspænding (min.): 220 V
Udgangs driftsspænding (min.): 220 V
Udgangs driftsspænding (maks.): 240 V
UPS topologi: Interaktivt indgangsstik
Strøm (maks.): 3.04 A
Bølgeform: Sine
Hørbare alarmtilstande: Fault,Low battery alarm,Overload alarm
Koldstart: Ja
Automatisk spændingsregulering (AVR): Ja
Uddgående frekvens: 50/60 Hz
EMI/RFI støjfiltrering: Ja
Antal indgående faser: 1
Regulering af udgangsspænding: -18; +10 %

Har du brug for hjælp?

Hvis du har brug for hjælp til Tripp Lite AVRX650UD stil et spørgsmål nedenfor, og andre brugere vil svare dig