Læs gratis den danske manual til Wolf Challenger XL C60SC (19 sider) i kategorien Ovn. Denne vejledning er vurderet som hjælpsom af 24 personer og har en gennemsnitlig bedømmelse på 4.4 stjerner ud af 12.5 anmeldelser. Har du et spørgsmål om Wolf Challenger XL C60SC, eller vil du spørge andre brugere om produktet?

Side 1/19
INSTALLATION & OPERATION MANUAL
CHALLENGER XL Series
Gas Restaurant Ranges
MODELS:
C24S C36(S,C)
C48(S,C) C48SS
C60(S,C)(S,C) C72(S,C)(S,C)
www.wolfrange.com
ITW Food Equipment Group, LLC
10405 Westlake Drive
Charlotte, NC 28273
RETAIN THIS MANUAL FOR FUTURE USE
FORM F35696 Rev. E (07-08)
- 4 -
LOCATION
The equipment area must be kept free and clear of combustible substances.
Installation clearances: COMBUSTIBLE NON-COMBUSTIBLE
CONSTRUCTION CONSTRUCTION
Back: 6" (152 mm) 0"
Right Side: 10" (254 mm) 0"
Left Side: 10" (254 mm) 0"
The installation location must allow adequate clearances for servicing and proper operation. A minimum
front clearance of 35" (889 mm) is required.
The ranges are suitable for installation on combustible floors when 6" (152 mm) adjustable legs or
casters are used. When legs or casters are removed, use only on noncombustible floors, curb, or
platform, with front appliance base projecting 3" (76 mm) beyond curb or platform.
The range(s) must be installed so that the flow of combustion and ventilation air will not be obstructed.
Adequate clearance for air openings into the combustion chamber(s) must be provided. Make sure
there is an adequate supply of air in the room to allow for combustion of the gas at the burners.
INSTALLATION CODES AND STANDARDS
Your Wolf Range must be installed in accordance with:
In the United States of Ame rica:
1. State and local codes.
2. National Fuel Gas Code, ANSI-Z223.1/NFPA #54 (latest edition). This shall include but
not be limited to: NFPA #54 Section 10.3.5.2 for Venting. Copies may be obtained
from The American Gas Association Accredited Standards Committee Z223, @ 400 N.
Capital St. NW, Washington, DC 20001 or the Secretary Standards Council, NFPA, 1
Batterymarch Park Quincy, MA 02169-7471.
NOTE: In the Commonwealth of Massachusetts
All gas appliances vented through a ventilation hood or exhaust system equipped with
a damper or with a power means of exhaust shall comply with 248 CMR.
3. NFPA Standard # 96 Vapor Removal from Cooking Equipment, latest edition, available
from the National Fire Protection Association, Batterymarch Park, Quincy, MA 02269.
In Canada:
1. Local codes.
2. CAN/CSA-B149.1 Natural Gas Installation (latest edition)
3. CAN/CSA-B149.2 Propane Installation Code (latest edition), available from the
Canadian Gas Association, 178 Rexdale Blvd., Etobicoke, Ontario, Canada M9W 1R3
The above are available from the Canadian Standard Association, 5060 Spectrum Way, Suite 100,
Mississauga, Ontario, Canada L4W 5N6.


Produkt Specifikationer

Mærke: Wolf
Kategori: Ovn
Model: Challenger XL C60SC

Har du brug for hjælp?

Hvis du har brug for hjælp til Wolf Challenger XL C60SC stil et spørgsmål nedenfor, og andre brugere vil svare dig




Ovn Wolf Manualer

Wolf

Wolf CI30460C/B Manual

1 April 2025
Wolf

Wolf CG304P/S Manual

5 Februar 2025
Wolf

Wolf DF484F Manual

14 Januar 2025
Wolf

Wolf CSO3050PS Manual

26 December 2024
Wolf

Wolf DF3665S Manual

26 December 2024
Wolf

Wolf CSO3050PM Manual

26 December 2024
Wolf

Wolf DF36450S Manual

26 December 2024
Wolf

Wolf DF36450C Manual

26 December 2024
Wolf

Wolf M Series Manual

15 Oktober 2024
Wolf

Wolf DF484CG Manual

6 Oktober 2024

Ovn Manualer

Nyeste Ovn Manualer