ABB A42 Manual

ABB Måling A42

Læs nedenfor 📖 manual på dansk for ABB A42 (2 sider) i kategorien Måling. Denne guide var nyttig for 11 personer og blev bedømt med 4.5 stjerner i gennemsnit af 2 brugere

Side 1/2
A41/A42/ A43/A44
INS ALL TION MANUALT A
2CMC484004M0201 January C 2021 Rev
Contact us
ABB SpA
Via Dell'industria, 18
20009 – Vittuone – Milano
Italy
Tel. +39 02 2415 0000
h w bb c m/ w-v gttps:/ / ne .a . o lo olta e
© Copyright 2021 ABB SpA. All rights reserved.
Speci ication subject to change without notice.
Ph2
5.5 mm
13 mm
1 7 104
L1
L2
L3
N
3x 80 A
4 wire , TPE+N
L1
L2
L3
N
3 9 126
L1
L2
L3
N
1 7 104
1 74
L1
L2
L3
L1
L2
L3
3 96
1 74
L1
L2
L3
3x 80 A
3 wire, TPE
2.5 mm
RS 485 I/O
6 mm
x1
ACT. NRG. IMP. TOT 1/4
1 2 3
OK
Start
1
1 2 3
x1
OK
ENERGY REGISTERS
2
x1
OK
SETTINGS
3
1 2 3
Transformer ratios
Ratios
OK
x1
1
1 2 3
2
x1
SET
1/1
Ratios: CT
1 2 3
0001/1
Ratios: CT
x5
OK
31 2 3
1/1
Ratios: CT
OK
x1
41 2 3
5
x1
SET
1/1
Ratios: VT
1 2 3
000001/100
Ratios: Voltage
OK
x9
61 2 3
1/1
Ratios: VT
OK
x1
71 2 3
Ratios
OK
x1
81 2 3
Wires
Wires
OK
x1
1
1 2 3
x1
SET
4, TPE+N
Wires: 3/4
2
1 2 3
3, TPE
Wires: 3/4
OK
x1
31 2 3
x1
3,TPE
Wires: 3/4
OK
41 2 3
Wires
OK
x1
5
1 2 3
Pul.out
x1
Pulse output
OK
1
1 2 3
x1
Act.Nrg.Imp
Pul.out 1: Quant
OK
21 2 3
x1
SET
100imp/kWh
Pul.out 1: Freq
31 2 3
000100imp/kWh
Pul.out 1: Freq
OK
x7
4123
x1
100imp/kWh
Pul.out 1: Freq
OK
51 2 3
x1
SET
100ms
Pul.out 1: Length
6123
x2
100ms
Pul.out 1: Length
OK
71 2 3
x2
100ms
Pul.out 1: Length
OK
8123
Clock
Clock:Date
OK
1
1 2 3
x1
Y:11M:3D:24
Clock:Date
SET
2
1 2 3
x6
Y:01M:03D:24
Clock:Date
OK
31 2 3
Y:12M:3D:24
Clock:Date
OK
x1
41 2 3
Clock:Time
x1
H:12M:41S:37
Clock:Time
SET
112 3
x6
H:12M:41S:37
Clock:Time
OK
21 2 3
x1
H:13M:41S:37
Clock:Time
OK
31 2 3
x1
OK
Clock
41 2 3
M-Bus
36 37
RS-485
35 36 37
C (Common) B (Rx/Tx-) A (RX/TX+)
1 ou tput (5-40 V DC, max 100 mA)
13 15
C out
Fixed 2 inputs/2 outputs
Inputs (24- 240 V DC/57-240 V AC)
Outputs (5-240 V AC/DC, max 100 mA)
13 15 16 17 18
C O1 O2 I1 I2
4 Programmable in/out
Inputs (24- 240 V DC/57-240 V AC)
Outputs (5-240 V AC/DC, max 100 mA)
C I/O1 I/O2 I/O3 I/O4
Transformers 4 wires, TPE+N
P1 P2
P1 P2
P1
S1
P2
S2
3x 10 A
L1
L2
L3
N
L1
L2
L3
N
3 4 7 92 5 81 6 11
S1 S2
S1 S2
(1.5 Nm)
(1.5 Nm)
(1.5
Nm)
(0.25 Nm)
(3.0 Nm)
(3.0 Nm)
(3.0 Nm)
L1 P1 P2
P1 P2
P1
S1
P2
S2
L2
L3
N
L1
L2
L3
N
4 6 7 9 111 3
S1 S2
S1 S2
(1.5 Nm)
A4X 4XX- and A4X 5XX-
(0.25 Nm)
Warning! Installation by person with electrotechnical
expertise only.
Warnung! Installation nur durch elektrotechnishe Fachkraft.
Avvertenzal! Fare installare solo da un elettricista qualicato.
Avertissement! Installation uniquement par des personnes
qualiées en électrotechnique.
Advertencia! La instalación deberá ser realizada
únicamente por electricistas especializados.
P1
S1
P2
S2
A4X 4XX- and A4X 5XX-
LP1
S1
P2
S2
N
L
N
1 2 3 5
Trasformer 2 wire
L L
N N
3 61 4
A42
A41
Frequency Length
LED Pulse indicator 40 msA41/A42 1000imp/kWh
A42/A44 5000 imp/kWh
Ut ilization cat egor y as of IEC 62052-31
A41 and A43: UC2
A42 and A44: UC1
Working with high volt age is potentially let hal.
Persons subjected t o high volt age may suffer
cardiac arrest , bur n injuries, or other severe injuries.
To avoid such injuries, make sure to disconnect t he
power supply befor e you start the inst allation.


Produkt Specifikationer

Mærke: ABB
Kategori: Måling
Model: A42

Har du brug for hjælp?

Hvis du har brug for hjælp til ABB A42 stil et spørgsmål nedenfor, og andre brugere vil svare dig