ActronAir CRV210T Manual


Læs nedenfor 📖 manual på dansk for ActronAir CRV210T (68 sider) i kategorien Klimaanlæg. Denne guide var nyttig for 32 personer og blev bedømt med 4.5 stjerner i gennemsnit af 16.5 brugere

Side 1/68
ADVANCE
Split Ducted Unit
Installation and Commissioning Guide - Outdoor
Model Numbers
CRV140S
CRV160S
CRV180S
CRV160T
CRV180T
CRV210T
CRV240T
IMPORTANT NOTE:
Please read this manual carefully before installing or operating your air conditioning unit.
Thats better. That’s Actron.
Installation and Commissioning Guide - Advance Split Ducted Outdoor Unit
Doc. No.0525-085 Ver. 2 22xxxx
Installation and Commissioning Guide Advance Outdoor Units
2
Table of Contents
Introduction .............................................................................................................................
General Information .................................................................................................................
Safety Instructions ...................................................................................................................
Installation Information ............................................................................................................
Operation Manual Access .........................................................................................................
Components Overview ...........................................................................................................
Control Panel  .........................................................................................................................
Single Phase (CRV140-180S) 11
Three Phase (CRV160-240T) 11
Unit Dimensions and Clearances  .............................................................................................
CRV140S 12
CRV160S / CRV160T / CRV180S / CRV180T 13
CRV210T / CRV240T 14
Unit Lifting Procedure  ............................................................................................................
Outdoor Unit Preparation  .......................................................................................................
Field Pipe Connection  .............................................................................................................
Piping and Brazing 19
Pressure Testing 22
Evacuation Procedure (Triple Evacuation) 22
Specifications for Refrigeration  ...............................................................................................
Electrical Installation ..............................................................................................................
Electrical Connection ..............................................................................................................
Split Unit ................................................................................................................................
Data Cable Shielding Instructions  ...........................................................................................
Circuit Breaker Size and Cable Size Requirement  .....................................................................
Wall Controller Options  ..........................................................................................................
Wall Controller Options 30
Wiring Configuration : Recommended 31
Wiring Connections ................................................................................................................
LR7-1 and LC7-2 Wall Control Wiring Connections 33
NEO Wall Control Wiring Connections 33
LM-RS-2 Optional Sensor Wiring Connections 34
AERSS Optional Duct Sensor Wiring Connections 34
Demand Response Management  .............................................................................................
Configuring and Commissioning Setup  ...................................................................................
Menu and Navigation 36
Configuring Compressor and Capacity(cnFg) 36
Configuring Control Source (CtrS) 36
Third Party Control Input (Indoor and/or Outdoor Board)  .......................................................
0-10V Analogue Input for Compressor and Indoor Fan 38
0-10V Analogue Input for Compressor with Fixed Indoor Fan Speed 39
Input for Fixed Compressor with Fixed Indoor Fan Speed 39
0-10V Analogue Input for Indoor Fan with Fixed Speed Compressor 40
Run and Fault Indication Output (Outdoor Board) 40
Remote On/Off 41


Produkt Specifikationer

Mærke: ActronAir
Kategori: Klimaanlæg
Model: CRV210T

Har du brug for hjælp?

Hvis du har brug for hjælp til ActronAir CRV210T stil et spørgsmål nedenfor, og andre brugere vil svare dig