APC Back-UPS BN450MNW Manual


Læs gratis den danske manual til APC Back-UPS BN450MNW (8 sider) i kategorien Uafbrydelig strømforsyning (UPS). Denne vejledning er vurderet som hjælpsom af 10 personer og har en gennemsnitlig bedømmelse på 4.8 stjerner ud af 5.5 anmeldelser. Har du et spørgsmål om APC Back-UPS BN450MNW, eller vil du spørge andre brugere om produktet?

Side 1/8
User Manual Back-UPS BN450MNW
Safety and General Information
Inspect the package contents upon receipt. Notify the carrier and dealer if there is
any damage.
SAVE THESE INSTRUCTIONS - This section contains important instructions that
should be followed during installation and maintenance of the UPS and batteries.
CAUTION: A battery can present a risk of electric shock and burns by high short-circuit
current.
CAUTION: Failed batteries can reach temperatures that exceed the burn thresholds for
touchable surfaces.
Inventory
DANGER
RISK OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH
This UPS is intended for indoor use only.
Do not operate this UPS in direct sunlight, in contact with fluids, or where
there is excessive dust or humidity.
Connect the UPS power cable directly to a wall outlet.
Be sure the air vents on the UPS are not blocked. Allow adequate space for
proper ventilation.
Failure to follow these instructions will result in death or serious injury.
bu462a
Back-UPS BN450MNW2
Connect the Battery
The Back-UPS is shipped with one battery cable disconnected.
Specifications
Remove the “Stop! Connect the Battery”
label that covers the outlets. The battery connector is located on the
underside of the unit.
Slide the battery connector handle away
from its disconnected position.
Turn the battery connector to a 90-degree
upright position and push it into the unit.
Model BN450MNW
Input Voltage 120 Vac Nominal
Frequency 50/60 Hz + 1 Hz auto-sensing
Brownout Transfers 92 Vac Typical
Over-voltage Transfer 139 Vac Typical
Output UPS Capacity 450 VA, 255 W
No. of Outlets 6
Battery Backup / Surge Outlets 4 / 2
Total output current 6 A
Voltage - On Battery 115 Vac ± 8%
Frequency - On Battery 50/60 Hz + 1 Hz
Transfer Time 4 ms Typical
Protection
and
Filtering
EMI/RFI Filter Full time
AC Input Resettable circuit breaker
Battery Type Sealed, maintenance-free, lead acid, 12 V
Average Life 3 - 5 years, the number of discharge cycles,
poor quality AC power, environmental
temperature and humidity may shorten the
battery lifetime
Charging Time 8 hours
bu
462a
bu463a
bu464a
bu465a


Produkt Specifikationer

Mærke: APC
Kategori: Uafbrydelig strømforsyning (UPS)
Model: Back-UPS BN450MNW

Har du brug for hjælp?

Hvis du har brug for hjælp til APC Back-UPS BN450MNW stil et spørgsmål nedenfor, og andre brugere vil svare dig




Uafbrydelig strømforsyning (UPS) APC Manualer

Uafbrydelig strømforsyning (UPS) Manualer

Nyeste Uafbrydelig strømforsyning (UPS) Manualer