Next, enter configuration mode by entering on the 123456
keypad and then Entry Symbol
. The central unit displays "Main
Menu - Wi-Fi AP mode".
Use the buttons to select " ". Confirm with No telephone
the button.
Here you can also use the buttons to set five phone
numbers to be used for voice call command and five phone
numbers to be used for text message command. Use the
button to return to the previous level to change the settings.
2. CODE CUSTOMISATION
For better security, please change the your central unit's secret
codes.
Enter configuration mode by entering 123456
on the keypad
and then Entry Symbol
. The central unit displays "Main Menu
- Wi-Fi AP mode".
Use the buttons to select " " (Settings). Paramètres
Confirm with the button. Next select " " then Access codes
confirm. Here you can change:
- The admin code that allows you to enter configuration
mode ( by default)123456
- The access code that allows you to disarm the central
unit using the keypad or a telephone (default code:
1234)
Do not forget these codes and do not write them down near
the central unit!
3. USAGE INSTRUCTIONS
Note: text message and voice call commands require a SIM
card installed in the central unit, and the numbers sending the
text messages or making the calls must be saved in the central
unit.
3.1 Fully armed
When you fully arm the system, any detection will trigger an alert
(typically used when you leave your home).
- Using the Avidsen Home app:
Open the app and click on " " (Arm).Armer
- Using the remote control:
Press the button on the remote control
- Using the central unit's keypad:
Press the button on the central unit
- By text message:
Text the number 1 to the phone number on the SIM card.
- By voice call:
Call the phone number on the SIM card. When your central unit
picks up, dial your access code ( by default) followed by 1234
the #sign. Then press on your phone.1
3.2 Partially armed
When you partially arm the system, detectors configured as
"Home Zone" will not trigger the alert (typically used when you
go to bed).
- Using the Avidsen Home app:
Open the app and click on " " (Home Mode).Mode Maison
- Using the remote control:
Press the button on the remote control
- Using the central unit's keypad:
Press the button on the central unit
- By text message:
Text the number to the phone number on the SIM card.2
- By voice call:
Not available
3.3 Disarmed
When disarming, only detectors configured as "Zone 24H" (24H
Zone) will trigger the alert. If the alarm has been triggered, the
siren will turn off.
- Using the Avidsen Home app:
Open the app and click on " " (Disarm).Désarmer
- Using the remote control:
Press the button on the remote control
- Using the central unit's keypad:
Enter your access code ( by default) then press the 1234
button on the central unit.
You can also disarm using the included RFID badge by swiping
it in front of the "RFID" zone of the central unit.
- By text message:
Text the number to the phone number on the SIM card.0
- By voice call:
Call the phone number on the SIM card. When your central unit
picks up, dial your access code ( by default) followed by 1234
the # sign. Then press on your phone.0
3.4 Alert trigger
If an active detector is triggered while the alarm is armed:
• The extremely loud siren built into the central unit will sound
(default time: 3 minutes)
• Avidsen Home app users immediately receive an alert push
notification
• The phone numbers stored for text messaging receive a
notification via text message (if a SIM card is installed in the
central unit).
• The phone numbers stored for voice calls are called one after
7. TECHNICAL SPECIFICATIONS
CENTRAL UNIT
Power supply 12V DC 1A mains adaptor (included)
Backup battery Integrated, Li-ion 7.4V 600mAh, bat-
tery life 8h on standby
Radio frequencies
WiFi 2.4GHz 802.11b/g/n
Mobile network
850/900/1800/1900MhZ
Wireless transmission accessories
433MHz, 80m open-air range
Contacts
Via mobile network (SIM card not
included)
Voice calls for up to 5 telephone
numbers
SMS for up to 5 telephone numbers
Via WiFi and the Avidsen Home appli-
cation: unlimited
Siren 95dBa to 1m
Maximum number
of accessories
Up to 10 remote controls
Up to 60 wireless sensors
Up to 30 RFID badges
Operating tempe-
rature
-10°C to 55°C
Humidity up to 80% without conden-
sation
Dimensions 185 x 125 x 25 mm
MOTION DETECTOR
Power supply 3Vdc by two 1.5V AA batteries,
included
Radio frequency 433 MHz open air range of 80m
Distance and angle
of detection 8m on a horizontal angle of 110°
Dimensions 107 x 53 x 32 mm
OPENING DETECTOR
Type Magnetic detector compatible with
swing or sliding doors and windows
Power supply 1.5Vdc by one 1.5V AA LR6 battery,
included
Radio frequency 433 MHz open air range of 80m
Dimensions 70.4 x 33.6 x 17.5 mm
REMOTE CONTROL
Power supply 3Vdc by 1 CR2020 battery, included
Radio frequency 433 MHz open air range of 80m
Dimensions 58.4 x 31.4 x 10.0 mm
RFID BADGE
Reading range 5 cm
Dimensions 107 x 53 x 32 mm
the other. If you pick up, you can disarm the system by using
your phone's keys to dial your access code ( by default) 1234
followed by the #sign. Then press on your phone.0
• Special case #1 24H Zone: if a detector is set to " " mode, it
will trigger the alert even if the central unit is disarmed.
• Special case #2: Entry Zone if a detector is set to " " mode,
you have a few seconds to disarm the alarm before the alert is
triggered.
4. OPERATING PRECAUTIONS
This product is designed for indoor use only.
Keep out of reach of children. Product installation and use must
comply with local laws.
5. MAINTENANCE AND CLEANING
Before cleaning your device, unplug it from the power supply
and flip the on/off switch. Use a soft, slightly damp cloth. Do not
use abrasive or corrosive substances.
Do not spray cleaning products directly on the product. The
product does not require any specific maintenance.
6. RECYCLING
Recycling: Disposing of used batteries in household
waste is strictly forbidden. Batteries/accumulators
containing harmful substances are marked with
symbols (shown opposite) which indicate that it is
forbidden to discard them in the household waste.
The corresponding heavy metals are referred to as follows:
Cd= cadmium, Hg= mercury, Pb= lead.
You can dispose of these used batteries/accumulators at
local waste treatment centres (centres for sorting recyclable
materials), which are required to accept them. Keep batteries
/ button cells / accumulators out of reach of children and store
them in a safe place not accessible to them. They could be
swallowed by children or pets. Risk of death! In the event that a
battery is swallowed, consult a doctor or go to A&E immediately.
Never short-circuit the batteries, and do not burn or recharge
them as they may explode!
Do not expose batteries/accumulators to extreme heat such as
sunlight or fire.
This logo denotes that devices no longer in use
should not be disposed of as household waste.
They are likely to contain hazardous substances
that are dangerous to both health and the
environment. Return the equipment to your local
distributor or use the recycling collection service
provided by your local council.