bebob factory GmbH – Höglwörtherstr. 350 81379 München Tel.: +49 89 27818282– D- –
www.bebob.de
November 2019
C harging
• Never leave batteries unattended while charging
• Wait 30 Minutes after discharge before you put the battery on a charger.
• VThe bebob 150micro battery can be charged with an external bebob charger (or
equivalent) with Lithium ion) charging ability.- -ion (Li
• Approximate charge time may vary depending on charger and temperature.
• V bebob 150micro can be charged in ambient temperature for optimum performance at
10°C 30°C.-
• V bebob 150micro batteries can be recharged in any charge condition.
D ischarging
• Maximum load is 16.0A. When using the battery with video or lighting equipment, power
consumption of the equipment must be A or below. For the protection of16.0 the battery, a
load of A or over may activate the internal protection circuit and stop supply of power. 16.0
In this case the status led will turn red.
• The battery can be used in ambient temperature of - 20°C - + 55°C.
Camera Data Communication
• Blue leds: Arri/Sony Data Protocol
• Red leds: Red Data Protocol
• To switch between both , press the Check button for 5sstatus
Status led
• Status led lighting Green: Full Capacity over 70% of New
• Status led lighting Yellow: Full Capacity between 50% and 70% of New
• Status led lighting : Full Capac under 50% of NewRed ity
Flash Light
• To switch On/Off press the Check Button Twice