Læs gratis den danske manual til Blaupunkt 5DA15260AU (20 sider) i kategorien Emhætte. Denne vejledning er vurderet som hjælpsom af 5 personer og har en gennemsnitlig bedømmelse på 4.6 stjerner ud af 3 anmeldelser. Har du et spørgsmål om Blaupunkt 5DA15260AU, eller vil du spørge andre brugere om produktet?

Side 1/20
Instruction manual
5DA17160AU
5DA15160AU
5DA15260AU
5DA17260AU
Extractor hood
2
1. SAFETY
INFORMATION
For your safety and cor-
ance, read this manual care-
fully before installation and
use. Always keep these in-
structions with the appliance
even if you move or sell it.
Users must fully know the
operation and safety features
of the appliance.
The wire connection has
to be done by specialized
technician.
The manufacturer will not be
held liable for any damages
resulting from incorrect or
improper installation.
The minimum safety dis-
tance between the cooker
top and the extractor hood
is 650 mm (some models
can be installed at a lower
height, please refer to the
paragraphs on working di-
mensions and installation).
If the instructions for installa-
tion for the gas hob specify
a greater distance, this must
be respected.
Check that the mains voltage
corresponds to that indicated
on the rating plate xed to
the inside of the hood.
Means for disconnection
must be incorporated in the
xed wiring in accordance
with the wiring rules.
For Class I appliances,
check that the domestic
power supply guarantees
adequate earthing.
Connect the extractor to the
exhaust ue through a pipe
of minimum diameter 120
mm. The route of the ue
must be as short as possi-
ble.
Regulations concerning the
discharge of air have to be
fullled.
Do not connect the extractor
hood to exhaust ducts carry-
ing combustion fumes (boil-
ers, replaces, etc.).
If the extractor is used in
conjunction with non-elec-
trical appliances (e.g. gas
burning appliances), a suf-
cient degree of aeration
must be guaranteed in the
room in order to prevent the
backow of exhaust gas.
When the cooker hood is
used in conjunction with
appliances supplied with
energy other than electric,
the negative pressure in the
room must not exceed 0,04
mbar to prevent fumes being
drawn back into the room by
the cooker hood.
The air must not be dis-
charged into a ue that is
used for exhausting fumes
from appliances burning gas
or other fuels.
If the supply cord is dam-
AU