Læs gratis den danske manual til Blaze BLZ-PROPB-NG (17 sider) i kategorien Ikke kategoriseret. Denne vejledning er vurderet som hjælpsom af 41 personer og har en gennemsnitlig bedømmelse på 4.8 stjerner ud af 21 anmeldelser. Har du et spørgsmål om Blaze BLZ-PROPB-NG, eller vil du spørge andre brugere om produktet?

Side 1/17
Page |
1
1
POWER BURNER
MODEL # BLZ-PB-LP/NG & BLZ-PROPB-LP/NG
INSTALLATION AND OPERATING
INSTRUCTIONS
INSTALLER: Leave these instructions with consumer.
CONSUMER: READ & retain for future reference.
Important: READ THESE INSTRUCTIONS CAREFULLY BEFORE STARTING INSTALLATION
SAFETY WARNINGS & CODES
DANGER
IF YOU SMELL GAS:
1. Shut off the gas to the appliance.
2. Extinguish any open flame.
3. Remove lid to vent.
4. If odor continues, keep away from the
appliance, and immediately call your
gas supplier or fire department.
WARNING
1. Do not store or use gasoline or other
flammable vapors and liquids in the
vicinity of this or any other appliance.
2. A propane cylinder not connected for use
shall not be stored in the vicinity of this
or any other appliance with flame.
CODE AND SUPPLY REQUIREMENTS: This power
burner must be installed in accordance with local codes
and ordinances, or, in the absence of local codes, with
either the latest National Fuel Gas Code (ANSI Z223.1/
NFPA 54), and Natural Gas and Propane Storage and
Handling Installation Code (CSA-B149.1).
This appliance and its individual shutoff valves must
be disconnected from the gas supply piping system
when testing the system at pressures in excess of
½ psi (3.5 kPa).
This appliance must be isolated from the gas supply
piping system by closing its individual manual
shut-off valves during any pressure testing of the
gas supply system at pressures up to and including
½ psi (3.5 kPa).
WARNING
Improper installation, adjustment, alteration,
service, or maintenance can cause injury or
property damage. Refer to this manual. For
assistance or additional information consult
a qualified professional installer, service
agency, or the gas supplier.
All electrical outlets in the vicinity of the power
burner must be properly grounded in
Accordance with local codes or, in the
absence of local codes, with the National
Electrical Code, ANSI/NFPA 70, or the
Canadian Electrical Code, CSA C22.1,
whichever is applicable.
Keep all electrical supply
cords and fuel supply
hoses away from any heated surface at all
times including any sharp object.


Produkt Specifikationer

Mærke: Blaze
Kategori: Ikke kategoriseret
Model: BLZ-PROPB-NG

Har du brug for hjælp?

Hvis du har brug for hjælp til Blaze BLZ-PROPB-NG stil et spørgsmål nedenfor, og andre brugere vil svare dig




Ikke kategoriseret Blaze Manualer

Blaze

Blaze Wall-S1 Manual

28 August 2024
Blaze

Blaze BLZ-PROPB-NG Manual

15 August 2024
Blaze

Blaze BLZ4LTELP Manual

14 August 2024
Blaze

Blaze BLZ4LP Manual

12 August 2024
Blaze

Blaze BLZ3NG Manual

11 August 2024
Blaze

Blaze BLZ5IJ Manual

11 August 2024
Blaze

Blaze BLZ5NG Manual

10 August 2024
Blaze

Blaze BLZSB2LP Manual

9 August 2024
Blaze

Blaze BLZSB1NG Manual

8 August 2024
Blaze

Blaze BLZ3LP Manual

7 August 2024

Ikke kategoriseret Manualer

Nyeste Ikke kategoriseret Manualer

Physa

Physa TR-3 Manual

2 November 2025
Hendi

Hendi 270882 Manual

2 November 2025
Obsidian

Obsidian WP1CAT6 Manual

2 November 2025
ANCEL

ANCEL FX6100 Manual

2 November 2025
ANCEL

ANCEL BST600 Manual

2 November 2025
ANCEL

ANCEL AJ600 GDI Manual

2 November 2025
Bogen

Bogen ATP35 Manual

2 November 2025
ANCEL

ANCEL AJ600 Manual

2 November 2025
Arktic

Arktic 204986 Manual

2 November 2025