Læs gratis den danske manual til Canarm BPT12-13H1 (6 sider) i kategorien Ventilator. Denne vejledning er vurderet som hjælpsom af 3 personer og har en gennemsnitlig bedømmelse på 4.7 stjerner ud af 2 anmeldelser. Har du et spørgsmål om Canarm BPT12-13H1, eller vil du spørge andre brugere om produktet?

Side 1/6
CANARMNACANARMNA
BATHROOM
EXHAUST FANS
BPT12-13H
OPERATION INSTRUCTIONS AND PARTS MANUAL
READ AND SAVE THESE INSTRUCTIONS
GENERAL SAFETY
WARNING - TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
1. This ventilation fan is approved for use over a bathtub or shower when installed in a GFCI protected circuit. Do not use unapproved
fans over a bathtub or shower that does not include a GFCI protected circuit.
2. Installation work must be carried out by a qualified person(s) in accordance with all local and safety codes including the rules for
fire-rated construction.
3. To reduce the risk of fire, always vent fans to the exterior and in compliance with local codes. Do not vent exhaust air into spaces
within walls, ceilings, attics, crawl spaces, or garages.
4. Install ductwork in a straight line with minimal bends.
5. Use 120 V, 60 Hz for the electrical supply and properly ground the unit. Follow all local safety and electrical codes.
6. Do not use this fan with any solid state control device; such as a dimmer switch. Solid-state controls may cause harmonic distortion,
which can cause a motor humming noise.
7. Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer.
8. Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to prevent power from
being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device,
such as a tag, to the service panel.
9. Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent
back drafting. Follow the heating equipment manufacturer’s guideline and safety standards such as those published by the National Fire
Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the
local code authorities.
10. Not to be installed in a ceiling thermally insulated to a value greater than R40. (This is required for installation in Canada only).
BPT12-13H-M-05_28_20 Page 1 of 3
When installing the ventilation fan in a , install new construction site
the main body of the fan and duct work during the rough‑in
construction of the building. The grill should be installed after the
finished ceiling is in place.
When installing in , use the dimensions shown existing construction
below to determine the required hole size for the ceiling.
Grill edges should overlap finished ceiling.
NOTE: If installing in existing construction, you must have access
to space above and below the installation location.
If you are replacing an existing fan, ensure that the new grill will
adequately cover the existing opening.
Do not install ventilation fan in areas where the duct work will require
configurations shown right.
PRE-INSTALLATION
BPT12-13H
(For bathroom size up to 75 ft
2
)
PRODUCT SPECIFICATIONS
MODEL DUCT DIAMETER VOLTAGE Hz POWER CONSUMPTION AIR DELIVERY @ 1” WG (CFM) NOISE WEIGHT
BPT12-13H
4” 120 60 17 WATTS 70 1 SONE 8.0 LBS
DIMENSIONS
4” OUTLET
10.7
6.7
6.8
0. 74
7.6
Turning angle too sharp Avoid duct shrink
Too many elbows Elbow near the body
Fan
Body
Minimum 18”
9.4
9.4
1. PREPARATION FOR MOUNTING (FIGURE 1)
Determine thickness of finished ceiling board (* measurement shown in
FIGURE 1). Place fan unit body against ceiling joist in desired location.
Ensure bottom of main body hangs down below joist to account for
finished ceiling board.
2.
MOUNTING FAN BODY (FIGURE 2)
Use long wood screws to loosely attach both sides of main body to joist
(right side shown). Ensure ventilation fan is level and that proper clearance
is given for finished ceiling board. When main body is level and in the
intended location, tighten screws on both right and left side of main body.
3.
USING QUICK CONNECT (FIGURE 3)
WARNING: Wiring must comply with all applicable electrical codes.
Turn power OFF before removing or installing connectors.
WARNING: COPPER to COPPER ONLY. Do not use on Aluminum wire.
CAUTION: The Quick Connect accessory part should be installed as
per instructions below.
NOTE: Connector is reusable on solid wires of the same wire gage or
smaller. Do not reuse connector on stranded wires.
a) Strip the wires so half of the bare wire is showing.
b) Grip the wire firmly and push the stripped end of the wire into the open
port of connector). Use only one stripped end of the wire per port.
c) Verify the stripped end of the wire is fully inserted to the back of the
connector.
NOTE: Important wire information. Maximum temperature rating 105°C (221°F).
600 volts maximum for building wire and 1000 volts maximum in signs and
lighting fixtures. Flammability rating of the wires must meet UL94-V2. The
acceptable wire range includes: Solid: 12-20 AWG, Stranded: 12-16 AWG ( 19
STRAND); 18AWG (7 STRAND), Tin bonded: 14-18 AWG ( 19 STRAND).
BEFORE YOU BEGIN
ITEM PICTURE QUANTITY
Fan Unit
1
Spring Clips
2
Grill
1
ITEM PICTURE QUANTITY
Quick Connect
3
Long Wood Screw
(4 x 30mm)
8
Screw
(4 x 6mm)
4
Bracket
4
CANARMNACANARMNA
BPT12-13H
BATHROOM EXHAUST FANS
BPT12-13H-M-05_28_20 Page 2 of 3
WARNING: TURN OFF ELECTRICITY AT BREAKER BOX
BEFORE BEGINNING INSTALLATION
INSTALLATION INSTRUCTIONS
1. Carefully unpack and remove the unit from the carton.
2. Check to make sure you have all components listed in the tables
shown right and below.
3. If any components are missing, please contact the manufacturer.
FIGURE 1
FIGURE 2
QUICK
CONN CE T
HOUS WIR SE E
PRODUC T
WIR SE
FIGURE 3


Produkt Specifikationer

Mærke: Canarm
Kategori: Ventilator
Model: BPT12-13H1

Har du brug for hjælp?

Hvis du har brug for hjælp til Canarm BPT12-13H1 stil et spørgsmål nedenfor, og andre brugere vil svare dig




Ventilator Canarm Manualer

Ventilator Manualer

Nyeste Ventilator Manualer