C40 SERIES
THERMOMETERS
C42C
C42F
C46
C48
C48C
For C42C Model only:
Meets the requirements of
DIN EN 13485:2002
“Thermometers for measuring the air and
product temperature for the transport,
storage and distribution of chilled, frozen,
deep-frozen/quick frozen food and
ice-cream”
the battery cover, which must t into the
hole provided in the back of the case.
* Philips No 1 or 5mm fl at blade screwdriver.
Technical Support
Please see:
www.comarkinstruments.com or
www.comarkUSA.com for details.
Warranty
Each Comark product is warranted to
be free from defects in material and
workmanship under normal use and
service. The warranty period is one
(1) year, unless otherwise stated, and
the warranty period begins on the date
of shipment. Temperature probes are
warranted for six (6) months.
The warranty extends only to the original
buyer or end-user of a Comark authorized
reseller. This warranty does not cover
damage resulting from normal wear
and tear, abuse, misuse, accidental
breakage, negligence, defects caused
by modifi cations, repair and servicing
not made or authorised by Comark
Instruments, damage caused by handling,
operating, storing, or using the product
outside the intended uses described
by our product literature. Disposable
batteries are also exempt from warranty.
Warranties on dishwasher safe models
apply only where the product has been
used in a commercial dishwasher.
Comark Instruments products are not
suitable for use or cleaning in domestic
dishwashers.
Comark’s warranty obligation is limited,
at Comark’s option, to refund of the
Thermistor 10 K Ohms unicurve
Thermocouple type T and K
6-pin Lumberg and Sub-Min Connectors
-40°C to +125°C / -40°F to +257°F
-200°C to +400°C / -328°F to +752°F
-200°C to 1372°C / -328°F to +2502°F
°C / °F
> -10
<1000°
≤ -10
≥ 1000°
0.1% ±0.2°C / ±0.4°F full range @ +23°C /
+73°F Ambient
±0.3°C 0°C to +70°C / ±0.6°F +32°F to +158°F
±0.5°C -20°C to +100°C / ±0.9°F -4°F to
+212°F
±0.5°C 0°C to +70°C / ±0.9°F +32°F to +158°F
*Typical accuracy with a Comark probe
< 0.005 degree/degree
< ± 0.01 % of reading ±0.02 °C/°C change from
+23°C / ±0.02°F/°F change from +73°F
-20°C to +50°C / -4°F to -122°F operating
4 digit, 12.5 mm LCD
Two Type I.E.C. LR6 Size AAAlkaline or
*Lithium recommended.
*Lithium is recommended for Low Temperature
environments, constantly below 10°C/50°F and
will give approximately 50% increased battery
life when used in lieu of Alkaline.
Up to 5000 hours
IP65


Produkt Specifikationer

Mærke: Comark
Kategori: Madtermometer
Model: C42

Har du brug for hjælp?

Hvis du har brug for hjælp til Comark C42 stil et spørgsmål nedenfor, og andre brugere vil svare dig




Madtermometer Comark Manualer

Comark

Comark BT125 Manual

21 August 2024
Comark

Comark BT42C Manual

20 August 2024
Comark

Comark N9094 Manual

20 August 2024
Comark

Comark BT48C Manual

20 August 2024
Comark

Comark CF400K Manual

20 August 2024
Comark

Comark C28 Manual

20 August 2024
Comark

Comark C42 Manual

20 August 2024
Comark

Comark PW200T Manual

20 August 2024
Comark

Comark C46 Manual

20 August 2024

Madtermometer Manualer

Nyeste Madtermometer Manualer