KM28 THERMOMETER
1. GETTING STARTED
Attach the probe to the instrument. Note that the
connector is polarised with a “thin” pin and a “wide”
pin, care needs to be taken to insert the probe the
correct way.
To turn the instrument on/off press and release the
on/off button on the left of the case.
If you do not turn the instrument off manually it will
switch off automatically after approximately 5/6
minutes.
3. SCALE SELECTION
Press the right hand button to change from °F to °C or
vice versa. The scale is displayed in the top right hand
of the window and is retained when switched off.
4. REPLACING THE BATTERY
Remove the battery cover by unscrewing the screw
on the rear of the unit. Do this away from the food
preparation area, taking care not to lose the screw.
The KM28 uses any standard 9 volt size battery and
these are readily available. Alkaline versions are
recommended for longest life.
Fit the battery and replace the cover. Take care not to
overtighten the screw or to leave too loose.
5. ACCESSORIES
PK19M Hypodermic needle probe
PK24M Penetration probe
CRS/5 Boot
6. SPECIFICATION
Sensor Type Thermocouple Type K
Measurement Range -40 to 1000°F /-40 to
500°C
Resolution 0.1° up to approx 195, 1°
above
Instrument Accuracy ±2°F / ±1°C
Ambient Temperature 32° to 122°F
Range 0° to 50°C
Battery 9V IEC 6LF22 standard/
alkaline
WARNINGS
TO AVOID DAMAGE OR BURNS, DO NOT MAKE TEMPERATURE
MEASUREMENTS IN MICROWAVE OR NORMAL OVENS.
DO NOT PLACE THE THERMOMETER IN A DISHWASHER AS IT IS NOT
DISHWASHER SAFE.
DO NOT PLACE THE THERMOMETER IN A FRIDGE OR FREEZER AS
DAMAGE MAY OCCUR DUE TO CONDENSATION FORMING WHEN THE
INSTRUMENT IS REMOVED.
REGULAR CLEANING OF THE THERMOMETER AND PROBES IS
RECOMMENDED USING A DAMP CLOTH AND NORMAL KITCHEN
CLEANER. DO NOT USE ANY FORM OF SOLVENT.
THIS IS A PRECISION INSTRUMENT AND SHOULD BE TREATED WITH
CARE IF LONG TERM PERFORMANCE IS TO BE ATTAINED.
© Comark Instruments Stock No. 16771 Issue 4
Comark Instruments
PO Box 500,
Beaverton, OR 97077, USA
Tel: (503) 643 5204
Email: sales@comarkusa.com
www.comarkusa.com
Comark Instruments
52 Hurricane Way,
Norwich, Norfolk, NR6 6JB, UK
Tel: +44 (0) 207 942 0712
Email: sales@comarkinstruments.com
www.comarkinstruments.com


Produkt Specifikationer

Mærke: Comark
Kategori: Madtermometer
Model: KM28

Har du brug for hjælp?

Hvis du har brug for hjælp til Comark KM28 stil et spørgsmål nedenfor, og andre brugere vil svare dig




Madtermometer Comark Manualer

Comark

Comark BT125 Manual

21 August 2024
Comark

Comark BT42C Manual

20 August 2024
Comark

Comark N9094 Manual

20 August 2024
Comark

Comark BT48C Manual

20 August 2024
Comark

Comark CF400K Manual

20 August 2024
Comark

Comark C28 Manual

20 August 2024
Comark

Comark C42 Manual

20 August 2024
Comark

Comark PW200T Manual

20 August 2024
Comark

Comark C46 Manual

20 August 2024

Madtermometer Manualer

Nyeste Madtermometer Manualer