Portable Electric Fireplace
Art.no 36-6312 Model EF480
Please read theentire instruction manual before using theproduct
and then save it for future reference. We reserve theright for
any errors in text or images and any necessary changes made
to technical data. In theevent of technical problems or other
queries, please contact our Customer Services.
Safety
Theproduct should only be connected to a230 V, 50 Hz
electrical outlet.
Never leave theproduct unattended whilst it is switched on.
If you have to leave theproduct unattended, even for
ashort while, always switch it off.
Keep theproduct out of childrens reach and do not allow
children to use it.
Theproduct is only intended for normal domestic use and
only in themanner described in this instruction manual.
Inspect themains lead regularly. Never use theproduct if
themains lead or plug has been damaged in any way.
Do not place themains lead on or near any hot surface.
Never cover theproduct.
Position theproduct so that there is always at least
15cm of free space on all sides to ensure adequate
air circulation. Never immerse theproduct in water or
any other liquid. Do not use theproduct in abathroom,
shower room or close to apool.
Theproduct is intended for indoor use only.
Do not touch theproduct if your hands are moist or wet.
Do not use theproduct on or near hot surfaces.
Never move theproduct by pulling on thelead.
Only use accessories that are recommended by
themanufacturer or retailer. Theuse of other accessories
can lead to arisk of injury to people and animals or
damage to theproduct.
Never place theproduct directly under awall socket.
Buttons and functions
Select anoperating mode using one of thebuttons.
Care and maintenance
Switch theelectric fireplace off, unplug it from theelectrical
outlet and let it cool completely before cleaning.
Wipe theelectric fireplace clean with asoft damp cloth.
Use only mild cleaning agents, never solvents or corrosive
chemicals.
Vacuum clean thefront and back (theair inlet and outlet)
of thefireplace at regular intervals.
Responsible disposal
1. [ II ] = 1200 W on/off
2. [ I ] = 600W on/off
3. [ I ] = Flame effect on/off
4. [ ] Thermostat
Note: Theelectric fireplace can be used with or without
heating effect.
Overheating protection
Theelectric fireplace is fitted with asafety cut-off switch that is
triggered when theproduct gets too hot. Theelectric fireplace
does not automatically reset itself, for safety reasons.
To reset thesafety cut-off switch once it has been triggered,
unplug theelectric fireplace and wait 15 minutes before
plugging it in again.
This symbol indicates that this product should not
be disposed of with general household waste. This
applies throughout theentire EU. In order to prevent
any harm to theenvironment or health hazards
caused by incorrect waste disposal, theproduct
must be handed in for recycling so that thematerial
can be disposed of in aresponsible manner.
When recycling your product, take it to your local
collection facility or contact theplace of purchase.
They will ensure that theproduct is disposed of in
anenvironmentally sound manner.
Specifications
Power supply 220–240 V, 50/60 Hz
Power 1200W
Size 34×25×17cm
Weight 3.8kg
This product is only suitable for well
insulated spaces or occasional use.
1 2
4
3
Information requirment for the electric local space heaters
Model identifier(s): EF480
Item Symbol Value Unit Item Unit
Heat output Type of heat input, for electric storage
local space heaters only (select one)
Nominal heat output Pnom 1.2 kW manual heat charge control, with
integrated thermostat No
Minimum heat output
(indicative) Pmin 0.6 kW
manual heat charge control with
room and/or outdoor temperature
feedback
No
Maximum continuous
heat output Pmax, c 1.2 kW
electronic heat charge control with
room and/or outdoor temperature
feedback
No
Auxiliary electricity
consumption --- --- --- fan assisted heat output No
At nominal heat
output elmax
0.014
(fan motor) kW Type of heat output/room temperature
control (select one)
At minimum heat
output elmin
0.014
(fan motor) kW single stage heat output and no
room temperature control No
In standby mode elSB 0 kW Two or more manual stages, no
room temperature control No
with mechanic thermostat room
temperature control Yes
with electronic room temperature
control No
electronic room temperature control
plus day timer No
electronic room temperature control
plus week timer No
Other control options (multiple
selections possible)
room temperature control, with
presence detection No
room temperature control, with open
window detection No
with distance control option No
with adaptive start control No
with working time limitation No
with black bulb sensor No
Contact details CLAS OHLSON AB, SE-793 85 INSJÖN, SWEDEN
Test Data
Commission Regulation (EC) No 1275/2008 Requirement
Mode Ecodesign requirements, from 7 January 2013 Result - Remark Verdict
Off mode Power consumption in ‘off mode’:
Power consumption of equipment in any off-mode
condition shall not exceed 0.50 W
0 W P
Standby mode Power consumption in ‘standby mode(s)’:
The power consumption of equipment in any
condition providing only a reactivation function,
or providing only a reactivation function and a
mere indication of enabled reactivation function,
shall not exceed 0.50 W.
N/A
The power consumption of equipment in any
condition providing only information or status
display, or providing only a combination of reacti-
vation function and information or status display
shall not exceed 1.00 W.
N/A
Seasonal space heating energy efficiency
Description Value
Seasonal space heating energy efficiency in active mode-ηS,on 40%
For electric local space heaters-ηth 100 %
The electric to primary energy ‘conversion coefficient-CC 2.5
F(1) is a correction factor accounting for a positive contribution to the seasonal space
heating energy efficiency of electric storage local space heaters due to adjusted
contributions for options for heat storage and output; and a negative contribution
to seasonal space heating efficiency for commercial local space heaters due to
adjusted contributions for options for the heat output, expressed in %;
0.0 %
F(2) is a correction factor accounting for a positive contribution to the seasonal
space heating energy efficiency due to adjusted contributions of controls of indoor
heating comfort, the values of which are mutually exclusive, cannot be added to
each other, expressed in %;
6.0 %
F(3) is a correction factor accounting for a positive contribution to the seasonal
space heating energy efficiency due to adjusted contributions of controls for indoor
heating comfort the values of which can be added to each other, expressed in %;
0.0 %
F(4) is a correction factor accounting for a negative contribution to the seasonal
space heating energy efficiency by auxiliary electricity consumption, expressed in %; 0.0 %
F(5) is a correction factor accounting for a negative contribution to the seasonal
space heating energy efficiency by energy consumption of a permanent pilot flame,
expressed in %.
0.0 %
Seasonal space heating energy efficiency-ηS36.00 %