Daikin 3MXM68N2V1B9 Manual

Daikin Aircondition 3MXM68N2V1B9

Læs gratis den danske manual til Daikin 3MXM68N2V1B9 (84 sider) i kategorien Aircondition. Denne vejledning er vurderet som hjælpsom af 47 personer og har en gennemsnitlig bedømmelse på 4.3 stjerner ud af 24 anmeldelser. Har du et spørgsmål om Daikin 3MXM68N2V1B9, eller vil du spørge andre brugere om produktet?

Side 1/84
Installer reference guide
R32 Split series
2MXM68N2V1B
3MXM40N2V1B9
3MXM40N2V1B8
3MXM40N2V1B7
3MXM52N2V1B9
3MXM52N2V1B8
3MXM52N2V1B7
3MXM68N2V1B9
3AMXM52N2V1B9
3AMXF52A2V1B9
3MXF52A2V1B9
3MXF68A2V1B9
4MXM68N2V1B9
4MXM80N2V1B9
5MXM90N2V1B9
Table of contents
Installer reference guide
2
2MXM68+3(A)MXM+3(A)MXF+4MXM+5MXM
R32 Split series
4P600463-1D – 2021.03
Table of contents
1 About the documentation 4
1.1 About this document ...................................................................................................................................................... 4
2 General safety precautions 5
2.1 About the documentation .............................................................................................................................................. 5
2.1.1 Meaning of warnings and symbols ................................................................................................................ 5
2.2 For the installer............................................................................................................................................................... 6
2.2.1 General ........................................................................................................................................................... 6
2.2.2 Installation site ............................................................................................................................................... 7
2.2.3 Refrigerant — in case of R410A or R32.......................................................................................................... 10
2.2.4 Electrical ......................................................................................................................................................... 12
3 Specific installer safety instructions 15
4 About the box 20
4.1 Overview: About the box................................................................................................................................................ 20
4.2 Outdoor unit ................................................................................................................................................................... 20
4.2.1 To unpack the outdoor unit ........................................................................................................................... 20
4.2.2 To remove the accessories from the outdoor unit........................................................................................ 21
5 About the unit 23
5.1 Overview: About the unit ............................................................................................................................................... 23
5.2 Identification ................................................................................................................................................................... 23
5.2.1 Identification label: Outdoor unit .................................................................................................................. 23
6 Unit installation 24
6.1 Preparing the installation site......................................................................................................................................... 24
6.1.1 Installation site requirements of the outdoor unit........................................................................................ 25
6.1.2 Additional installation site requirements of the outdoor unit in cold climates............................................ 27
6.2 Opening the unit ............................................................................................................................................................. 28
6.2.1 About opening the unit .................................................................................................................................. 28
6.2.2 To open the outdoor unit............................................................................................................................... 28
6.3 Mounting the outdoor unit............................................................................................................................................. 28
6.3.1 About mounting the outdoor unit ................................................................................................................. 28
6.3.2 Precautions when mounting the outdoor unit.............................................................................................. 29
6.3.3 To provide the installation structure ............................................................................................................. 29
6.3.4 To install the outdoor unit ............................................................................................................................. 30
6.3.5 To provide drainage........................................................................................................................................ 30
6.3.6 To prevent the outdoor unit from falling over .............................................................................................. 31
7 Piping installation 32
7.1 Preparing refrigerant piping ........................................................................................................................................... 32
7.1.1 Refrigerant piping requirements.................................................................................................................... 32
7.1.2 Refrigerant piping insulation.......................................................................................................................... 33
7.1.3 Refrigerant piping length and height difference ........................................................................................... 34
7.2 Connecting the refrigerant piping .................................................................................................................................. 35
7.2.1 About connecting the refrigerant piping ....................................................................................................... 35
7.2.2 Precautions when connecting the refrigerant piping.................................................................................... 35
7.2.3 Guidelines when connecting the refrigerant piping...................................................................................... 36
7.2.4 Pipe bending guidelines ................................................................................................................................. 37
7.2.5 To flare the pipe end ...................................................................................................................................... 37
7.2.6 Connections between outdoor and indoor unit using reducers................................................................... 38
7.2.7 Using the stop valve and service port............................................................................................................ 40
7.2.8 To connect the refrigerant piping to the outdoor unit ................................................................................. 42
7.3 Checking the refrigerant piping...................................................................................................................................... 42
7.3.1 About checking the refrigerant piping........................................................................................................... 42
7.3.2 Precautions when checking the refrigerant piping........................................................................................ 43
7.3.3 To check for leaks........................................................................................................................................... 43
7.3.4 To perform vacuum drying............................................................................................................................. 44
8 Charging refrigerant 46
8.1 About charging refrigerant ............................................................................................................................................. 46
8.2 About the refrigerant...................................................................................................................................................... 47
8.3 Precautions when charging refrigerant.......................................................................................................................... 48
8.4 To determine the additional refrigerant amount .......................................................................................................... 48
8.5 To determine the complete recharge amount .............................................................................................................. 48
8.6 To charge additional refrigerant..................................................................................................................................... 49


Produkt Specifikationer

Mærke: Daikin
Kategori: Aircondition
Model: 3MXM68N2V1B9

Har du brug for hjælp?

Hvis du har brug for hjælp til Daikin 3MXM68N2V1B9 stil et spørgsmål nedenfor, og andre brugere vil svare dig