Daikin EWAD810C Manual


Læs gratis den danske manual til Daikin EWAD810C (70 sider) i kategorien Computer køling komponent. Denne vejledning er vurderet som hjælpsom af 66 personer og har en gennemsnitlig bedømmelse på 4.8 stjerner ud af 33.5 anmeldelser. Har du et spørgsmål om Daikin EWAD810C, eller vil du spørge andre brugere om produktet?

Side 1/70
CONTROL PANEL OPERATING MANUAL
AIR-COOLED SCREW CHILLER
MICROTECH III CONTROLLER
D – EOMAC00A10-12EN
D – EOMAC00A10-12EN
- 2 -
Table of Contents
INTRODUCTION .......................................... 3
OPERATING LIMITS: ................................. 4
CONTROLLER FEATURES ....................... 4
GENERAL DESCRIPTION ......................... 5
C
ONTROL
P
ANEL
L
AYOUT
............................ 5
P
OWER
P
ANEL
L
AYOUT
................................ 6
C
ONTROLLER
D
ESCRIPTION
......................... 7
H
ARDWARE
S
TRUCTURE
.............................. 7
S
YSTEM
A
RCHITECTURE
............................... 8
SEQUENCE OF OPERATION .................. 10
CONTROLLER OPERATION .................. 13
M
ICRO
T
ECH
III
I
NPUTS
/O
UTPUTS
.............. 13
E
XTENSION
I/O
C
OMPRESSOR
#1
TO
#3 ...... 14
I/O
EXV
C
IRCUIT
#1
TO
#3 ........................ 14
E
XTENSION
I/O
F
AN
M
ODULE
C
IRCUIT
#1
&
2 ................................................................. 15
E
XTENSION
I/O
F
AN
M
ODULE
C
IRCUIT
#3 . 15
E
XTENSION
I/O
U
NIT
A
LARM
&
L
IMITING
. 15
S
ETPOINTS
.................................................. 16
UNIT FUNCTIONS ..................................... 20
C
ALCULATIONS
.......................................... 20
U
NIT
T
YPE
.................................................. 20
A
UNIT CAN BE CONFIGURED AS
C
HILLER OR
MCU
(
MOTOCONDENSING UNIT
).
W
HEN THE
UNIT IS CONFIGURED AS
MCU
THE
EXV
CONTROL LOGIC AND ALL THE RELATED
VARIABLES AND ALARMS ARE DISABLED
, ... 20
U
NIT
E
NABLE
............................................. 20
U
NIT
M
ODE
S
ELECTION
............................. 20
U
NIT
C
ONTROL
S
TATES
.............................. 21
U
NIT
S
TATUS
.............................................. 22
I
CE
M
ODE
S
TART
D
ELAY
........................... 22
E
VAPORATOR
P
UMP
C
ONTROL
................... 22
N
OISE
R
EDUCTION
..................................... 23
L
EAVING
W
ATER
T
EMPERATURE
(LWT)
R
ESET
......................................................... 23
U
NIT
C
APACITY
C
ONTROL
......................... 25
U
NIT
C
APACITY
O
VERRIDES
...................... 27
H
EAT
R
ECOVERY
........................................ 28
H
EAT
R
ECOVERY
P
UMP
.............................. 29
CIRCUIT FUNCTIONS .............................. 30
C
ALCULATIONS
.......................................... 30
C
IRCUIT
C
ONTROL
L
OGIC
........................... 31
C
IRCUIT
S
TATUS
......................................... 32
C
OMPRESSOR
C
ONTROL
............................. 32
C
ONDENSER
F
AN
C
ONTROL
........................ 34
EXV
C
ONTROL
(
FOR CHILLER UNITS
) ......... 36
E
CONOMIZER
C
ONTROL
.............................. 37
S
UBCOOLER
C
ONTROL
................................ 37
L
IQUID
I
NJECTION
...................................... 37
ALARMS AND EVENTS ............................ 38
S
IGNALING
A
LARMS
................................... 38
C
LEARING
A
LARMS
.................................... 38
D
ESCRIPTION OF
A
LARMS
.......................... 38
U
NIT
E
VENTS
.............................................. 40
O
PTION
A
LARMS
........................................ 41
O
PTION
E
VENTS
......................................... 41
C
IRCUIT
S
TOP
A
LARMS
.............................. 42
C
IRCUIT
E
VENTS
........................................ 46
A
LARM
L
OGGING
....................................... 47
USING THE CONTROLLER .................... 48
N
AVIGATING
.............................................. 49
OPTIONAL REMOTE USER INTERFACE
........................................................................ 56
START-UP AND SHUTDOWN ................. 58
T
EMPORARY
S
HUTDOWN
............................ 58
E
XTENDED
(S
EASONAL
)
S
HUTDOWN
.......... 59
FIELD WIRING DIAGRAM ...................... 61
BASIC CONTROL SYSTEM
DIAGNOSTIC .............................................. 62
CONTROLLER MAINTENANCE ............ 64
FREECOOLING CONTROL (IF
AVAILABLE) ............................................... 65
APPENDIX ................................................... 66
D
EFINITIONS
............................................... 66
Unit controllers are L
ON
M
ARK
certied with an optional
L
ON
W
ORKS
communications module


Produkt Specifikationer