Daikin EZESHP20AUAW1B Manual

Daikin Køleskab EZESHP20AUAW1B

Læs gratis den danske manual til Daikin EZESHP20AUAW1B (36 sider) i kategorien Køleskab. Denne vejledning er vurderet som hjælpsom af 3 personer og har en gennemsnitlig bedømmelse på 4.4 stjerner ud af 2 anmeldelser. Har du et spørgsmål om Daikin EZESHP20AUAW1B, eller vil du spørge andre brugere om produktet?

Side 1/36
Operation manual
Exigo E1500 Trailer Refrigeration Unit
English
Operation manual
Exigo E1500 Trailer Refrigeration Unit
EZESHP20AUAW1B
EZLSHP20AUAW1B
Table of contents
Operation manual
2
EZESHP20AUAW1B + EZLSHP20AUAW1B
Exigo E1500 Trailer Refrigeration Unit
4P726855-1C – 2025.03
Table of contents
1
About this document 2
2
General safety precautions 3
2.1
About the documentation........................................................... 3
2.1.1
Meaning of warnings and symbols.............................. 3
2.2
Hazard identification .................................................................. 3
2.3
In case of emergency ................................................................ 4
2.4
For the user ............................................................................... 5
2.5
How to secure a safety harness ................................................ 8
3
About the unit and options 9
3.1
About the system....................................................................... 9
3.2
Certification labels ..................................................................... 9
3.3
Components .............................................................................. 9
3.4
Safety systems .......................................................................... 10
3.5
Possible options for the unit ...................................................... 11
4
User interface 11
4.1
Overview.................................................................................... 11
4.1.1
Function of the HMI buttons........................................ 12
4.1.2
Overview of the pages behind the buttons.................. 12
4.2
Basic functions .......................................................................... 12
4.2.1
To update the HMI and PCB software ........................ 12
4.2.2
IoT FW update occurence........................................... 14
4.2.3
To start up................................................................... 14
4.2.4
To change an operation mode from ON to OFF ......... 16
4.2.5
To set the Set Point .................................................... 17
4.2.6
To select a working mode ........................................... 17
4.2.7
To go through the menu.............................................. 17
4.2.8
To view the TRENDS page......................................... 18
4.2.9
To adapt the settings .................................................. 18
4.2.10
To activate the engine bleeding function .................... 20
4.2.11
To view the COUNTERS page ................................... 20
4.2.12
To view usage data..................................................... 20
4.2.13
To access the password-protected pages .................. 21
4.2.14
To manually start the defrost mode ............................ 21
4.2.15
To change the start & stop/continuous mode
selection...................................................................... 22
4.2.16 To activate start & stop in perishable range................ 22
5
Before operation 23
6
Operation 23
6.1
Operation range......................................................................... 23
6.2
Operation procedure.................................................................. 23
6.3
Loading the goods ..................................................................... 24
6.4
General recommended checks.................................................. 24
6.4.1
Pre-trip inspection (PTI) .............................................. 24
7
Energy saving and optimum operation 25
8
Maintenance and service 26
8.1
Cleaning the unit........................................................................ 27
8.1.1
To clean the exterior ................................................... 27
8.1.2
To clean the interior .................................................... 27
8.2
Maintenance before a long stop period ..................................... 27
8.3
Maintenance after a long stop period ........................................ 28
8.4
To jump-start the unit................................................................. 28
8.5
Scheduled maintenance ............................................................ 28
8.6
To check the engine-, compressor- and unit fixation bolts and
nuts............................................................................................ 29
9
Troubleshooting 30
9.1
Error codes: Overview ............................................................... 31
9.2
Symptoms that are NOT system malfunctions .......................... 33
9.2.1
Symptom: The diesel engine does not start................ 33
10
Disposal 33
11
Glossary 34
1
About this document
Thank you for purchasing this product. Please:
Read the documentation carefully before operating the user
interface to ensure the best possible performance.
Keep the documentation for future reference.
Always keep this document together with the unit. After use,
always store it in the storage compartment.
Target audience
Endusers
INFORMATION
This appliance is intended to be used by expert or trained
users.
Documentation set
This document is part of a documentation set. The complete set
consists of:
Installation manual:
Installation instructions
Format: Paper (in the box of the unit) + Digital files on https://
www.daikin.eu. Use the search function
to find your model.
Operation manual:
User instructions
Format: Paper (in the box of the unit) + Digital files on https://
www.daikin.eu. Use the search function
to find your model.
Latest revisions of the supplied documentation may be available on
the regional Daikin website or via your installer.
The original instructions are written in English. All other languages
are translations of the original instructions.
Technical engineering data
A subset of the latest technical data is available on the regional
Daikin website (publicly accessible).
The full set of the latest technical data is available on the Daikin
Business Portal (authentication required).
A printed version of the declaration of conformity, the wiring- and
piping diagrams is included with the unit.
For questions, information or support contact the 24/7 number +32
59 552477.
A QR code with a direct link to the online manuals can be found:
On a decal, located on the right door, below the HMI.
On the user interface, Menu → USAGE DATA


Produkt Specifikationer

Mærke: Daikin
Kategori: Køleskab
Model: EZESHP20AUAW1B

Har du brug for hjælp?

Hvis du har brug for hjælp til Daikin EZESHP20AUAW1B stil et spørgsmål nedenfor, og andre brugere vil svare dig




Køleskab Daikin Manualer

Daikin

Daikin LREQ5B7Y1 Manual

3 September 2025
Daikin

Daikin EZESHP20AUAW1B Manual

3 September 2025
Daikin

Daikin JEHSCU0680CM3 Manual

3 September 2025
Daikin

Daikin JEHSCU0250CM3 Manual

3 September 2025
Daikin

Daikin JEHCCU0135CL1 Manual

3 September 2025
Daikin

Daikin JEHCCU0077CM1 Manual

3 September 2025
Daikin

Daikin JEHSCU0750CL3 Manual

3 September 2025
Daikin

Daikin JEHCCU0100CM1 Manual

3 September 2025
Daikin

Daikin JEHSCU0250CM1 Manual

3 September 2025
Daikin

Daikin LRMEQ4BY1 Manual

3 September 2025

Køleskab Manualer

Nyeste Køleskab Manualer

Turbo Air

Turbo Air PRO-26H-RI Manual

3 September 2025
Amica

Amica BM210.4 Manual

3 September 2025
Jenn-Air

Jenn-Air JURFL242HL Manual

3 September 2025
Hisense

Hisense RBPF185ABID Manual

3 September 2025
Amica

Amica FM135.4 Manual

3 September 2025
Haier

Haier HFR7819ENGC Manual

3 September 2025
Exquisit

Exquisit SBS 130-4 A+ Manual

3 September 2025
Turbo Air

Turbo Air EST-72-N-V Manual

3 September 2025
Vintec

Vintec VWS830FAS-X Manual

3 September 2025