Daikin FTXZ50NV1B Manual
Daikin
Klimaanlæg
FTXZ50NV1B
Læs nedenfor 📖 manual på dansk for Daikin FTXZ50NV1B (48 sider) i kategorien Klimaanlæg. Denne guide var nyttig for 24 personer og blev bedømt med 4.8 stjerner i gennemsnit af 12.5 brugere
Side 1/48

English
Français
Español
Italiano
Eλληνικά
Pyccкий
Türkçe
MODELS
FTXZ25NV1B
FTXZ35NV1B
FTXZ50NV1B
DAIKIN ROOM AIR CONDITIONER
OPERATION MANUAL

Before Operation
Safety precautions 3 ......................................................................................................
Names and functions of parts 5 .....................................................................................
Preparation before operation 9 ......................................................................................
To set the batteries To set the clock
To set the position where the indoor unit is installed
Basic Operation
To set operation modes 11 .............................................................................................
AUTO COOLING “SARARA” DRY DRY COOLING HEATING
“URURU” HUMIDIFY HUMID HEATING FAN ONLY
To adjust the air ow .................................................................................................. 13
To adjust the air ow rate To adjust the air ow direction
Useful Functions
To operate wisely using the sensor ........................................................................... 16
3 Area INTELLIGENT EYE AUTO OFF
To use the timer 17 ........................................................................................................
ON/OFF TIMER COUNTDOWN OFF TIMER
To ensure a comfortable sleep .................................................................................. 19
COMFORT SLEEP TIMER
To guarantee high heating capacity when you wake up ............................................ 21
QUICK HEATING TIMER
To increase the cooling or heating power .................................................................. 23
POWERFUL
CONTENTS
Tips for saving energy
A. Cover windows with a blind or a curtain.
Blocking sunlight and air from outdoors increases
the cooling/heating effect.
B. Be careful not to cool the room too much.
Keeping the temperature setting at a moderate level
helps save energy.
Recommended temperature setting
• For cooling: 26-28°C
• For heating: 20-24°C
C. Keep air lter clean.
Clogged air lters cause inef cient operation and waste energy.
When the AUTO CLEANING FILTER operation is enabled, the
air conditioner cleans the lter periodically. Ef cient operation is
available at any time without concerns about dirt. Page 28
AC
B

To purify the air in the room ...................................................................................... 24
FLASH STREAMER AIR PURIFYING FRESH AIR SUPPLY VENTILATION
To consider the environment of use .......................................................................... 25
ECONO OUTDOOR UNIT QUIET
To keep the air conditioner clean .............................................................................. 27
MOLD PROOF CLEANING FILTER
To know the status of your room and air conditioner ................................................. 30
INFORMATION
To change the default settings .................................................................................. 31
Menu settings
Cleaning
Cleaning (for service personnel) ............................................................................... 35
< When the TIMER lamp (orange) blinks > ....................................................................................36
< When the MOLD PROOF / CLEANING FILTER lamp (green) blinks > ......................................37
When the Need Arises
When the OPERATION lamp (green) blinks 40 .............................................................
FAQ ........................................................................................................................... 41
Troubleshooting (for service personnel) .................................................................... 42
Tips for your comfort
INTELLIGENT EYE sensor
When the INTELLIGENT EYE sensor is used, the sensor detects the movement
of a person and adjusts the airow direction and operation.
Do you want to direct the airow away from you?
Do you want to save power consumption in a room with no person in it?
The sensor will cooperate with you. Page 15, 16
FLASH STREAMER
Flash streamer decomposes mold and allergic substances.
It keeps air in the room and the inside of the air conditioner clean to make a
comfortable space. Page 24
The English text is the original instruction.
Other languages are translations of the original instructions.
English
Before Operation
Basic Operation
Useful Functions
Cleaning
When the Need
Arises

3
Read the precautions in this manual carefully
before operating the unit. This appliance is lled with R32.
• Keep this manual where the user can easily nd it.
• The precautions described herein are classied as WARNING and CAUTION. They both contain important information regarding safety.
Be sure to observe all precautions without fail.
WARNING .....................
Failure to follow these instructions properly may result in personal injury or loss of life.
CAUTION ...................... Failure to observe these instructions properly may result in property damage or
personal injury, which may be serious depending on the circumstances.
Never attempt. Be sure to follow the instructions. Be sure to establish an earth
connection.
• After reading, keep this manual in a convenient place so that you can refer to it whenever necessary. If the equipment is transferred to a
new user, be sure also to hand over the manual.
WARNING
• Do not use means to accelerate the defrosting process or to clean, other than those recommended by the manufacturer.
• The appliance must be stored in a room without continuously operating ignition sources (for example: open ames, an
operating gas appliance or an operating electric heater).
• Do not pierce or burn.
• Be aware that refrigerants may not contain an odour.
• The appliance must be installed, operated and stored in a room with a oor area larger than 1.8m
2.
• In order to avoid re, explosion or injury, do not operate the unit when harmful, among which ammable or corrosive gases, are
detected near the unit.
• Be aware that prolonged, direct exposure to cool or warm air from the air conditioner, or to air that is too cool or too warm can
be harmful to your physical condition and health.
• Do not place objects, including rods, your ngers, etc., in the air inlet or outlet. Product malfunctioning, product or injury
damage may result due to contact with the air conditioner’s high-speed fan blades.
• Do not attempt to repair, dismantle, reinstall or modify the air conditioner yourself as this may result in water leakage, electric
shocks or re hazards.
• Do not use ammable spray near the air conditioner, or otherwise re may result.
• Do not use a refrigerant other than the one indicated on the outdoor unit (R32) when installing, moving or repairing. Using
other refrigerants may cause trouble or damage to the unit, and personal injury.
• To avoid electric shocks, do not operate with wet hands.
• Beware of re in case of refrigerant leakage. If the air conditioner is not operating correctly, i.e. not generating cool or warm air,
refrigerant leakage could be the cause. Consult your dealer for assistance. The refrigerant within the air conditioner is safe and
normally does not leak.
However, in the event of a leakage, contact with a naked burner, heater or cooker may result in generation of noxious gas. Do
not use the air conditioner until a qualied service person conrms that the leakage has been repaired.
• Do not attempt to install or repair the air conditioner yourself. Improper workmanship may result in water leakage, electric
shocks or re hazards. Please contact your local dealer or qualied personnel for installation and maintenance work.
• When the air conditioner is malfunctioning (giving off a burning odour, etc.) turn off power to the unit and contact your local
dealer. Continued operation under such circumstances may result in a failure, electric shocks or re hazards.
• Be sure to install an earth leakage circuit breaker. Failure to install the earth leakage circuit breaker may result in electric
shocks or re.
• Be sure to earth the unit. Do not earth the unit to a utility pipe, lightning conductor or telephone earth lead. Imperfect earthing
may result in electric shocks.
CAUTION
• Do not use the air conditioner for purposes other than those for which it is intended. Do not use the air conditioner for cooling
precision instruments, food, plants, animals or works of art as this may adversely affect the performance, quality and/or
longevity of the object concerned.
• Do not expose plants or animals directly to airow from the unit as this may cause adverse effects.
Safety precautions

4
• Do not place appliances that produce naked ames in places exposed to the airow from the unit as this may impair
combustion of the burner.
• Do not block air inlets nor outlets. Impaired airow may result in insufcient performance or trouble.
• Do not sit on the outdoor unit, put things on the unit, or pull the unit. Doing so may cause accidents, such as falling or toppling
down, thus resulting in injury, product malfunctioning, or product damage.
• Do not place objects that are susceptible to moisture directly beneath the indoor or outdoor units. Under certain conditions,
condensation on the main unit or refrigerant pipes, air lter dirt or drain blockage may cause dripping, resulting in fouling or
failure of the object concerned.
• After prolonged use, check the unit stand and its mounts for damage. If they are left in a damaged condition, the unit may fall
and cause injury.
• To avoid injury, do not touch the air inlet or aluminium ns of the indoor or outdoor units.
• The appliance is not intended for use by unattended young children or inrm persons. Impairment of bodily functions and harm
to health may result.
• Children should be supervised to ensure that they do not play with the unit or its remote controller. Accidental operation by a
child may result in impairment of bodily functions and harm health.
• Avoid impacts to the indoor and outdoor units, or otherwise product damage may result.
• Do not place ammable items, such as spray cans, within 1m of the air outlet.
The spray cans may explode as a result of hot air from the indoor or outdoor units.
• Be careful not to let pets urinate on the air conditioner. Urination on the air conditioner may result in electric shocks or re.
• Do not wash the air conditioner with water, as this may result in electric shocks or re.
• Do not place water containers (vases etc.) above the unit, as this may result in electric shocks or re hazards.
• To avoid oxygen depletion, ensure that the room is adequately ventilated if equipment such as a burner is used together with
the air conditioner.
• Before cleaning, be sure to stop unit operation, turn off the circuit breaker or remove the power cord. Otherwise, an electric
shock and injury may result.
• Only connect the air conditioner to the specied power supply circuit. Power supplies other than the one specied may result in
electric shocks, overheating and res.
• Arrange the drain hose to ensure smooth drainage. Imperfect drainage may cause wetting of the building, furniture etc.
• Do not place objects in direct proximity of the outdoor unit and do not let leaves and other debris accumulate around the unit.
Leaves are a hotbed for small animals which can enter the unit. Once in the unit, such animals can cause malfunctions, smoke
or re when making contact with electrical parts.
• Do not place objects around the indoor unit.
Doing so may have an adverse inuence on the performance, product quality, and life of the air conditioner.
• This appliance is not intended to be used by persons with reduced physical, sensory or mental capabilities, or with lack of
operation knowledge, unless they have been given supervision or instruction concerning the appliance use by person
responsible for their safety.
Keep out of children’s reach to ensure that they do not play with the appliance.
• For care and cleaning, call service personnel.
P002
This is an appliance that is not accessible to the general public.
Installation site
< To install the air conditioner in the following types of environments, consult the dealer >
• Places with an oily environment or where steam or soot occurs.
• Salty environment such as coastal areas.
• Places where sulde gas occurs such as hot springs.
• Places where snow may block the outdoor unit.
• The indoor unit is at least 1m away from any television or radio set (unit may cause interference with the picture or sound).
• The drain from the outdoor unit must be discharged to a place of good drainage.
Consider nuisance to your neighbours from noises
< For installation, choose a place as described below >
• A place solid enough to bear the weight of the unit which does not amplify the operating sound or vibration.
• A place from where the air discharged from the outdoor unit or the operating sound will not annoy your neighbours.
Electrical work
• For power supply, be sure to use a separate power circuit dedicated to the air conditioner.
System relocation
• Relocating the air conditioner requires specialized knowledge and skills. Please consult the dealer if relocation is necessary for
moving or remodeling.
Before Operation

5
Names and functions of parts
Indoor unit
INTELLIGENT EYE sensorAir inlet
(top surface)
Front panel
Air outlet
Shutter
(bottom
air inlet)
Model name plate
Auxiliary ap
(horizontal blade)
Page 13
Flap (horizontal blade)
Page 13
Louvres (vertical blades)
(Inside of the air outlet located on the
right and left sides.) Page 13
< List of lamps >
Lamp Colour State Description
TIMER lamp orange Lights up TIMER is set. Page 17
Blinks It is time to clean the streamer unit. Page 36
OPERATION lamp green Lights up The air conditioner is running.
Blinks Check the error code. Page 40
QUICK HEATING TIMER
lamp
dark red
Lights up
QUICK HEATING TIMER is set. Page 21
bright red Preparatory heating operation or QUICK HEATING TIMER operation is
running. Page 21
MOLD PROOF /
CLEANING FILTER lamp green Lights up
The air conditioner is running with the AUTO MOLD PROOF set to “On”.
Page 27
MOLD PROOF operation or CLEANING FILTER operation is running.
Page 27, 28
Blinks It is time to clean the dust box. Page 37
Transmitter/Receiver
• Sends/receives signals to/from the remote
controller.
• The OPERATION lamp blinks with beep
sound to indicate signal reception.
Case Sound type
Operation start beep-beep
Setting change beep
Operation stop long beep
MOLD PROOF /
CLEANING FILTER lamp (green)
QUICK HEATING TIMER lamp (red)
OPERATION lamp (green)
TIMER lamp (orange)
Display

6
Before Operation
When the front panel is open Page 35
Air supply lter (black)
Removes dust taken in from
the outdoor air. Page 39
Streamer unit
Prevents mold and allergens
with the decomposition power
of the streamer discharge.
Page 36
Photocatalytic air-
purifying and
deodorising lter
(black)
Adsorbs mold, allergens and
odour. Page 39
Indoor temperature
and humidity sensor
(inside the unit)
Detects the temperature and
humidity in the room.
Humidifying temperature
and humidity sensor
(inside the unit)
Detects the temperature and
humidity of the humidi ed air to
control the degree of humidity.
Dust box
Scrapes dust off the air lter with the dust
brush and collects it. Page 37
Air lter (white)
(2 locations at right and left) Page 38
Display unit
INTELLIGENT EYE sensor
Detects human motion to
con rm that a person is in
the area.
Indoor unit ON/OFF switch
• Press to start the operation with the mode set to
“AUTO” and air ow rate to “AUTO”.
Press the button again to stop the operation.
• Use this button when no remote controller is
immediately available.
Outdoor unit
Drain outlet
(rear side of the bottom)
Drains water out from the outdoor unit during HEATING or
HUMID HEATING operation.
Outdoor temperature sensor
(back)
Detects the outdoor temperature.
Drain hose
Drains water from the indoor unit
during COOLING, “SARARA” DRY or
DRY COOLING operation.
Model name plate
Refrigerant pipes, inter-unit
wire and humidifying hose
Earth terminal (inside)
Humidifying unit air inlet
(front and back)
Humidifying unit air
outlet (front)
Humidifying unit
Air inlet
(side and back)
Air outlet

7
Names and functions of parts
Remote controller
Notes on remote controller
• Take care to avoid dropping the remote controller or getting it wet. (Dropping or getting it wet may break it.)
• When the remote controller gets dirty, wipe it with a dry soft cloth.
• Signal communication may become poor if an electronic-starter-type uorescent lamp (such as inverter-type lamps) or TV is in the room.
Consult the service shop if that is the case.
• The sensitivity may become poor if the transmitter/receiver is exposed to direct sunlight.
Display (LCD), with backlight
• Displays the operating conditions.
(All displayed here for your reference
• Press any of the operation buttons to
the backlight for about 5 seconds.
• Before use, peel off the protection sheet.
Direct operation buttons
Starts the COOLING, “SARARA” DRY,
HEATING or “URURU” HUMIDIFY operation.
Page 11
Transmitter/Receiver
Transmitter/Receiver
• Sends/receives signals to/from the indoor
unit.
• The remote controller must be used with the
transmitter/receiver pointed towards the
transmitter/receiver of the indoor unit.
Transmission will fail if there is an
obstruction such as a curtain between the
remote controller and indoor unit.
• The maximum distance for communication is
about 7m.
AUTO button
Automatically selects an appropriate operation
mode (COOLING or HEATING) based on the
indoor temperature and starts the operation.
Page 11
OFF button
Stops the operation. Page 11
Cover
After you open the cover, close it
completely. The buttons on the
cover will not function properly if
the cover is not securely closed.
Cover
TEMPERATURE button
Adjusts the temperature setting. Page 12
HUMIDITY button
Adjusts the humidity setting. Page 12
FAN button
Adjusts the air ow rate setting. Page 13
OFF TIMER button
Sets the time until the operation stops.
Page 18
FLASH STREAMER AIR PURIFYING /
FRESH AIR SUPPLY VENTILATION
button
• Performs streamer discharge.
• Fresh air is taken in from outside. Page 24
Model ARC477A1

9
Preparation before operation
33
22
11
Upper tab
Lower tab
(2 locations)
Do not confuse
the and sides.
To set the batteries
1. Pull down the upper tab to open the
cover.
2. Insert 2 dry batteries AA.LR6 (alkaline).
• Using batteries other than AA.LR6 (alkaline) may lead to
improper operation.
3. Insert the 2 lower tabs on the cover to put
the cover back in place.
Remote controller
holder
Screws
Hole Projection
To x the remote controller holder to a wall
1. Choose a place where the signals can
reach the unit.
2. Fix the remote controller holder to a wall,
a pillar, or similar location with the screws
procured locally.
3. Fit the projection of the remote controller
holder into the hole at the back of the
remote controller.
Turn on the circuit breaker
• After the power is turned on, the aps of the indoor unit open and
close once to set the reference position.
Notes on batteries
• The batteries will last for about 1 year. If the remote controller display begins to fade and the reception degrades within
1 year, however, replace both batteries with new AA.LR6 (alkaline) ones at the same time.
• The batteries that come with the remote controller are for initial operation. The batteries may run out in less than 1 year.
• When the TIMERS are set, the settings are cancelled after replacing the batteries. Set the TIMERS again.
• When the air conditioner is not used for a long time, take the batteries out.

10
To set the clock
1. Press .
2. Press to set the clock to the current
time.
• Each time you press , the time changes by 1 minute. If
you press and hold the button, the time changes by
10 minutes.
3. Press .
• After “ CLOCK Set ” appears, the normal screen is
displayed again.
< To set the clock after replacing the batteries >
When the clock is set, the set time is saved in the indoor unit. After replacing the batteries,
direct the remote controller toward the indoor unit and press . (The time will be set
automatically.) If “12:00” keeps on blinking, follow steps 1 to 3 above.
To set the position where the indoor unit is installed
Set “INSTALLED POSITION” in the menu settings.
• To adjust the airow properly, set the “INSTALLED POSITION”. Page 31, 33
To set the brightness of the indoor unit lamps
Press .
BRIGHTNESS High
(default)
BRIGHTNESS Low BRIGHTNESS Off
Note on setting the clock
• If the indoor unit’s internal clock is not set to the correct time, the ON/OFF TIMER, COMFORT SLEEP TIMER and QUICK HEATING
TIMER will not operate punctually.
Before Operation

11
To set operation modes
OPERATION lamp (green)
AUTO operation
To operate in appropriate operation mode (COOLING or HEATING)
based on the set temperature and the indoor temperature.
Press .
COOLING operation
To lower the temperature.
Press .
“SARARA” DRY operation
To lower the humidity.
Press .
DRY COOLING operation
To lower the temperature and humidity.
Press during COOLING operation.
• during “SARARA” DRY operation to switch the Press
operation to DRY COOLING.
HEATING operation
To raise the temperature.
Press .
“URURU” HUMIDIFY operation
To raise the humidity.
Press while the unit is not
operating.
HUMID HEATING operation
To raise the temperature and humidity.
Press during HEATING
operation.
• Press the button again to go back to HEATING operation.
• Press during HEATING operation or during “URURU”
HUMIDIFY operation to switch the operation to HUMID HEATING.
FAN ONLY operation
To blow air.
Press .
< To stop the operation >
Press .

12
To adjust the temperature
Press .
To adjust the humidity
Press .
Notes on humidity settings
Setting Description
: MOISTURISING Keeps the humidity high and does not blow air directly on the body to make the operation gentle to your
skin.
The operation is recommended when you are worried about the dryness of your skin. The airow rate
cannot be changed.
: CONTINUOUS Continues humidifying or dehumidifying.
: HIGH Humidies or dehumidies with high power.
: STANDARD Humidies or dehumidies with moderate power.
: LOW Humidies or dehumidies with low power.
: OFF Does not perform humidity control.
Notes on temperature and humidity settings in each operation mode
Mode Temperature Humidity
AUTO 18-30ºC The humidity setting is not available.
COOLING 18-32ºC *3
DRY COOLING MOISTURISING, CONTINUOUS, LOW, STANDARD, HIGH or OFF *4
“SARARA” DRY CONTINUOUS, LOW, STANDARD or HIGH*1
HEATING 10-30ºC *5
HUMID HEATING OFF *6 , LOW, STANDARD, HIGH, CONTINUOUS or MOISTURISING
“URURU” HUMIDIFY LOW, STANDARD, HIGH or CONTINUOUS*2
*1 When the temperature is changed, the DRY COOLING operation starts.
*2 When the temperature is changed, the HUMID HEATING operation starts.
*3 When the humidity is lowered, the DRY COOLING operation starts.
*4 When “OFF” is selected, the COOLING operation starts.
*5 When the humidity is raised, the HUMID HEATING operation starts.
*6 When “OFF” is selected, the HEATING operation starts.
Notes on “SARARA” DRY operation
• This mode mixes dehumidied cool air with room air to adjust the air outlet temperature and remove moisture.
• When the indoor temperature rises, the DRY COOLING operation automatically starts.
• When the outdoor temperature is lower than the indoor temperature, dehumidifying is less effective.
• When the outdoor temperature is lower than 18ºC, the room is dehumidied by alternating the COOLING and HEATING operations. In
addition, the ventilation is controlled properly and the room humidity is lowered by taking outdoor air into the room. (Air intake
dehumidifying)
Notes on DRY COOLING operation
• In order to lower the humidity, the airow rate during the DRY COOLING operation becomes lower than that in the COOLING operation.
• When the humidity is not lowered, “SARARA” DRY operation automatically starts.
Note on “URURU” HUMIDIFY operation
• The humidifying unit collects moisture from the outdoor air to humidify the room.
Note on HUMID HEATING operation
• When the indoor temperature rises by HEATING operation, the indoor humidity may drop temporarily.
Basic Operation

15
To adjust the air ow
Note on 3-D air ow
• Using 3-D air ow circulates cold air, which tends to collect at the bottom of the room, and hot air, which tends to collect near the ceiling,
throughout the room, preventing areas of cold and hot developing.
Note on horizontal air ow direction
• When the horizontal air ow direction is set to “AUTO”, the INTELLIGENT EYE sensor is activated. The INTELLIGENT EYE sensor
detects a person in the left-side, front, and right-side areas and directs the air ow away from that person.
< INTELLIGENT EYE sensor >
The INTELLIGENT EYE sensor detects the movements of a person (heat-generating object) to con rm where people are.
Example (for Comfort) Page 16
• The maximum distance that people can be detected is about 9m in front of the indoor unit.
• The movement of small animals including dogs and cats or a temperature change due to a heat-generating object such as another
heating appliance or electrical appliance may incorrectly be detected as a person. In addition, areas exposed to sunlight may
incorrectly be detected as a person.
• If several persons are detected in the same room, the air ow direction is changed based on the position of the last detected
person.
• The area just under or right beside the indoor unit cannot be detected.
• Application range is as follows.
60°
70°
9m
70°
9m
Vertical angle 60°
(Side view)
Horizontal angle 140°
(Top view)

16
To operate wisely using the sensor
3 Area INTELLIGENT EYE operation
Whether to blow air away from a person or not can be set according to your preference. The
INTELLIGENT EYE sensor detects the movement of a person and automatically changes the
airow direction.
AUTO OFF operation
When the INTELLIGENT EYE sensor judges that there is no one in the room, it changes the
set temperature +2°C in COOLING / –2°C in HEATING operation. When the set time elapses
with no change in the condition, the air conditioner automatically stops the operation.
< To use the operation >
Press and select the setting of your preference.
• Each time you press the button, the setting changes.
INTELLIGENT EYE
On AUTO OFF
On BOTH
On BOTH
Off
• “ ”, “ ”, or “ ” is displayed on the LCD.
Settings of 3 Area INTELLIGENT EYE
Focus Blows air on a person.
Comfort * Does not blow air on a person.
* Default setting
You can change the setting at “INTELLIG.EYE AIRFLOW” of the menu settings. Page 31, 32
Settings of AUTO OFF
1 HR * Stops the operation 1 hour after the sensor judges that there is no
one in the room.
3 HR Stops the operation 3 hours after the sensor judges that there is no
one in the room.
* Default setting
You can change the setting at “AUTO OFF time” of the menu settings. Page 31, 32
< To cancel the operation >
Press and select “BOTH Off”.
• “ ”, “ ”, or “ ” disappears from the LCD.
Note on 3 Area INTELLIGENT EYE operation
• POWERFUL operation is cancelled when 3 Area INTELLIGENT EYE is selected.
Note on 3 Area INTELLIGENT EYE and AUTO OFF operations
• If no presence detected in the room for 20 minutes, the air conditioner changes the set temperature +2°C in COOLING / –2°C in
HEATING operation.
When the indoor temperature exceeds 30°C, the operation changes the temperature +1°C in COOLING operation from set temperature.
Useful Functions

17
1/ 4
TIMER lamp (orange)
ON/OFF TIMER operation
This function controls the operation start and stop time.
When you set the timer, you can select the operation frequency either once or daily.
< To use the operation >
1. Press .
2. Press to select the item and press .
24 HOUR ON TIMER
24 HOUR OFF TIMER
C-SLEEP TIMER Page 19
QUICK HEAT TIMER Page 21
1/ 4
3. Press to select the item and press .
ON TIMER (once)
DAILY ON TIMER (daily)
2/ 2
4. Press to set the start/stop time and press .
• The time that was set last is displayed (from the second time).
• Each time you press , the time changes by
10 minutes. If you press and hold the button, the time changes
continuously.
• After setting, the set time and “ ” or “ ” are displayed on
the LCD. When daily is selected, “DAILY” is displayed on the
LCD as well.
• The TIMER lamp (orange) lights up.
ON TIMER
OFF TIMER
< To change or cancel the setting >
1. Follow steps 1 and 2 above and then select the TIMER
you want to change.
2. Press to select the item and press .
Setting change
TIMER cancel
To use the timer

19
To ensure a comfortable sleep
3/ 4
COMFORT SLEEP TIMER operation
COMFORT SLEEP TIMER operation keeps the indoor temperature and humidity at suitable
levels for a comfortable sleep and refreshing morning.
< To use the operation >
1. Press during COOLING or HEATING operation.
2. Press to select the item and press .
24 HOUR ON TIMER Page 17
24 HOUR OFF TIMER Page 17
C-SLEEP TIMER
QUICK HEAT TIMER Page 21
3/ 4
3. Press to set the wake-up time and press .
• The time that was set last is displayed (from the second time).
• Each time you press , the time changes by
10 minutes. If you press and hold the button, the time changes
continuously.
• When this timer is set, the wake-up time and “ ” are
displayed on the LCD.
< To change or cancel the setting >
1. Follow steps 1 and 2 above and then select the TIMER
you want to change.
2. Press to select the item and press .
Setting change
TIMER cancel
• Settings can be cancelled with .
• If the menu screen is open, press twice.

20
Notes on COMFORT SLEEP TIMER operation
• When COMFORT SLEEP TIMER is set, the upper limit of the set temperature of HUMID HEATING is 22°C.
• After the COMFORT SLEEP TIMER operation is nished, the operation displayed on the remote controller will continue.
• If you set the COMFORT SLEEP TIMER while the ON TIMER is set, the ON TIMER will be cancelled.
< Temperature control of COMFORT SLEEP TIMER operation >
• Once COMFORT SLEEP TIMER operation starts, the temperature will be lowered 2°C in the next 3 hours, and then raised
1°C one hour before you wake up. (V-shaped temperature control)
Example (for 6 hours of sleep)
Set temperature
Sleeping hours
During your sleep After you wake up
0123456
–1°C
–2°C
ON
ke-upWake-up
Wake-up timeWake-up time
hours3 hours hours2 hours 1 hour1 hour
V-shaped temperature control works most effectively over
periods of 4 or more hours of sleep.
< Humidity control of COMFORT SLEEP TIMER operation >
• In DRY COOLING and HUMID HEATING operations, humidity is controlled based on the standard humidity.
Standard humidity is the humidity determined by operation mode and set temperature.
(“STD” is displayed on the LCD.)
• When the preset humidity is “MOISTURISING”, humidity is constantly controlled on a higher level.
(“ ” is displayed on the LCD.)
• In COOLING and HEATING operations, the humidity is not controlled.
Example (for 6 hours of sleep)
Standard humidity
0 1 2 3 4 5 6
Sleeping hours
Humidity
MOISTURISING
–10%
2 hours 4 hours
HUMID HEATING: +10%
DRY COOLING: +5%
Useful Functions

21
To guarantee high heating capacity when you wake up
4/4
QUICK HEATING TIMER operation
This operation quickly blows warm air when the HEATING operation starts in the morning and
makes a warm space (warmth zone) around the indoor unit.
How to set the QUICK HEATING TIMER
1. Press .
2. Press to select the item and press .
24 HOUR ON TIMER Page 17
24 HOUR OFF TIMER Page 17
C-SLEEP TIMER Page 19
QUICK HEAT TIMER
4 / 4
3. Press to set the QUICK HEATING time and press
.
• Each time you press , the time changes by 10 minutes.
If you press and hold the button, the time changes continuously.
• QUICK HEATING TIMER is set.
• The QUICK HEATING TIMER lamp (dark red) lights up.
4. Press to stop the operation.
When the operation stops, defrosting operation automatically starts. (night defrosting)
What happens in the morning?
The air conditioner starts warming up about 30 minutes before the set QUICK HEATING time.
(preparatory heating operation)
The QUICK HEATING TIMER lamp (dark red) becomes brighter for a duration of about
30 minutes before and after the set QUICK HEATING time.
5. Con rm that the QUICK HEATING TIMER lamp (bright
red) is illuminating and then press .
• The QUICK HEATING TIMER operation is performed for about
30 minutes.
• The OPERATION lamp (green) lights up.
• If is not pressed, the preparatory heating operation will
stop after about 30 minutes of QUICK HEATING time.
About 30 minutes later, the air conditioner starts the normal
HEATING operation.

22
< To change or cancel the setting >
1. Follow steps 1 and 2 on page 21 and then select the timer setting you want to
change.
2. Press to select the item and press .
Setting change
TIMER cancel
• Settings can be cancelled with .
• If you cancel the QUICK HEATING TIMER operation halfway through, the operation goes back to the normal HEATING operation
Pressing also goes back to the normal HEATING operation.
< To stop the operation >
Press .
Example
QUICK HEATING time is set to 7:00.
6:30 7:307:00
Preparatory heating operation starts.
QUICK HEATING time
If is not pressed, the
air conditioner stops
operating.
is pressed.
is pressed.
QUICK HEATING TIMER is set.
(QUICK HEATING TIMER lamp (dark red)
lights up.)
Preparatory heating operation is running.
(QUICK HEATING TIMER lamp (bright red)
lights up.)
QUICK HEATING TIMER operation is running.
(QUICK HEATING TIMER lamp (bright red)
and OPERATION lamp (green) light up.)
Normal HEATING operation is running.
(OPERATION lamp (green) lights up.)
Notes on warmth zone
• By blowing warmer air than the normal setting at a
lower air ow rate, a warmth zone is created around
the indoor unit.
• This function is effective within about 1.5m or less
from the wall where the indoor unit is installed.
Vertical
air ow direction
Horizontal
air ow direction
The vertical air ow direction is set at the
5th level. The horizontal air ow direction
preserves the previous settings.
Warmth zone
Notes on QUICK HEATING TIMER operation
• To blow warm air quickly, preparatory heating operation is performed for about 30 minutes before and after the set QUICK HEATING
time. In this step, electric power is consumed.
• During the preparatory heating operation the aps open and the fan starts rotating. Also warm air may be blown.
• If you go out and do not use the air conditioner for a long time, cancel the QUICK HEATING TIMER.
• Warm air may be blown at a later stage just after the QUICK HEATING TIMER lamp becomes red or when the protection control works.
• When the indoor temperature is 20°C or higher, or when the outdoor temperature is 16°C or higher, the preparatory heating operation
does not start.
• “URURU” HUMIDIFY operation is not performed while the QUICK HEATING TIMER operation is performed.
Useful Functions

23
To increase the cooling or heating power
POWERFUL operation
POWERFUL operation quickly maximises the cooling/heating effect. You can get the maximum
capacity.
< To use the operation >
Press during COOLING or HEATING operation.
• When POWERFUL operation is set, the operation mode will be
changed as follows.
COOLING /
DRY COOLING
POWERFUL COOLING
(set temperature 18°C)
HEATING /
HUMID HEATING
POWERFUL HEATING
(set temperature 30°C)
• “ ” is displayed on the LCD.
• POWERFUL operation ends in 20 minutes. Then the system
automatically operates again with the previous settings which
were used before POWERFUL operation.
• Temperature and airow rate cannot be changed.
< To cancel the operation >
Press again.
• “ ” disappears from the LCD.
• The operation mode returns to the previous setting.
• POWERFUL operation is cancelled when , the direct
operation buttons, , or is pressed.
Notes on POWERFUL operation
• The unit’s operating sound becomes louder during operation.
• You may not feel sufcient warmth for a while after the operation starts because this operation supplies a higher airow rate than the
normal HEATING operation and the blown air temperature may be lower.
• When using POWERFUL operation, there are some functions which are not available.
• POWERFUL operation will not increase the capacity of the air conditioner if the air conditioner is already in operation with its maximum
capacity demonstrated.
• To maximize the cooling/heating effect, the capacity of outdoor unit is increased and the airow rate is xed to the maximum setting.

24
To purify the air in the room
FLASH STREAMER AIR PURIFYING operation
Flash streamer discharge decomposes mold and allergic substances
to clean the air in the room.
FRESH AIR SUPPLY VENTILATION operation
The air in the room is cleaned, taking in fresh air from outside.
< To use the operation >
Press .
• Each time you press the button, the setting changes.
CLEAN On
FRESH On *1
CLEAN On
FRESH High *2
CLEAN On
FRESH Off
CLEAN Off
FRESH Off
*1 Ventilation is performed at an automatically adjusted airow rate.
*2 Ventilation is performed at a high airow rate.
• “ ”, “ ”, or “ ” is displayed on the LCD.
(These symbols are not displayed while the unit is not operating.)
< To stop the operation >
Press .
< To cancel the setting >
Press and select “Off”.
• “ ”, “ ”, or “ ” disappears from the LCD.
• The operation mode returns to the previous setting.
Note on FLASH STREAMER AIR PURIFYING operation
• When the airow becomes weak during operation, the streamer discharge may stop temporarily to prevent a small amount of ozone
smell coming from the air outlet.
Notes on FRESH AIR SUPPLY VENTILATION operation
• Sounds from outdoors may be heard or odours may be taken in. Also, the unit’s operating sound becomes a little louder.
• The unit’s operating sound may be different depending on the outdoor temperature and humidity.
Useful Functions

25
To consider the environment of use
ECONO operation
ECONO operation enables efcient operation by limiting the maximum
power consumption value.
This function is useful for ensuring a circuit breaker does not trip when
the unit runs alongside other appliances.
OUTDOOR UNIT QUIET operation
OUTDOOR UNIT QUIET operation lowers the noise level of the
outdoor unit by changing the frequency and fan speed on the outdoor
unit. This function is useful when you need to consider minimizing
noise in your neighbourhood, such as during the night.
< To use the operation >
Press during operation and select the setting of
your preference.
• Each time you press the button, the setting changes.
ECONO On
QUIET Off
ECONO Off
QUIET On
BOTH On BOTH Off
• “ ”, “ ”, or “ ” is displayed on the LCD.
< To cancel the operation >
Press and select “Off”.
• “ ”, “ ”, or “ ” disappears from the LCD.
Notes on the settings of ECONO and OUTDOOR UNIT QUIET in each operation mode
Mode ECONO OUTDOOR UNIT QUIET
AUTO /
COOLING / DRY COOLING /
HEATING / HUMID HEATING
“SARARA” DRY
–
“URURU” HUMIDIFY / FAN ONLY – –

26
Notes on ECONO operation
< Image of running current and power consumption in ECONO operation >
Time
Maximum during normal operation
Maximum during ECONO operation
Normal
operation
ECONO
operation
From start up until set temperature is reached
The maximum running current and power consumption of
the air conditioner in ECONO operation vary with the
connecting outdoor unit.
• Pressing causes the settings to be cancelled, and “ ” disappears from the LCD.
• If the level of power consumption is already low, ECONO operation will not lower the power consumption.
•
POWERFUL and ECONO operation cannot be used at the same time. Priority is given to the function of whichever button is pressed last.
Notes on OUTDOOR UNIT QUIET operation
• POWERFUL operation and OUTDOOR UNIT QUIET operation cannot be used at the same time. Priority is given to the function of
whichever button is pressed last.
•
Even when operation is stopped with or indoor unit ON/OFF switch,
“
”
will remain on the remote controller display unless the
settings are cancelled.
• OUTDOOR UNIT QUIET operation will lower neither the frequency nor fan speed if they have already been lowered enough.
Useful Functions

27
To keep the air conditioner clean
MOLD PROOF / CLEANING FILTER
lamp (green)
MOLD PROOF operation
The inside of the air conditioner is dried to reduce the occurrence of mold and odour.
When COOLING, “SARARA” DRY, or DRY COOLING operation is performed, condensation
may occur inside the air conditioner and may cause mold or odour. It is recommended to dry
the inside of the air conditioner by MOLD PROOF operation.
< To automatically operate: Default “Off” >
Press for about 2 seconds during operation.
• “ ” is displayed on the LCD.
• MOLD PROOF operation automatically dries the inside of the air
conditioner each time after the COOLING, “SARARA” DRY, or DRY
COOLING operation is stopped.
• The MOLD PROOF / CLEANING FILTER lamp (green) lights up.
• The operation stops automatically in 100 minutes.
< To cancel the setting >
Press again for about 2 seconds.
• “ ” disappears from the LCD.
< To manually operate >
Press for about 2 seconds while the unit is not
operating.
• “MOLD PROOF” is displayed on the LCD, and the display
returns to normal after a while.
•
The MOLD PROOF / CLEANING FILTER lamp (green) lights up
during the operation.
• The operation stops automatically in 100 minutes.
< To cancel the operation halfway through >
Press .
• The MOLD PROOF / CLEANING FILTER lamp goes out.
Notes on automatic operation
100 minutes 100 minutes
COOLING / “SARARA” DRY / DRY COOLING operation is running.
MOLD PROOF operation is running.
• After COOLING, “SARARA” DRY, or DRY COOLING
operation stops, the air conditioner starts the MOLD
PROOF operation automatically, and then stops
automatically in 100 minutes.
• Even when COOLING is selected in the AUTO
operation, the AUTO MOLD PROOF operation is
started when the AUTO operation is stopped.
• If the operation is turned off by COUNTDOWN OFF
TIMER or OFF TIMER, AUTO MOLD PROOF is not
performed.

29
Notes on MOLD PROOF operation
• This operation dries the inside of the air conditioner with the FAN ONLY and HEATING operation.
• This operation dries the inside of the air conditioner while streamer discharge is performed to reduce the development of mold and
odour inside the air conditioner. But the function does not remove any adhered dust and mold.
• The HEATING operation will not start when the outdoor temperature is 24°C or higher or the indoor temperature is higher.
• The aps may sometimes close to increase the drying effect inside the air conditioner.
• When the MOLD PROOF / CLEANING FILTER lamp blinks, clean the dust box and reset the dust box cleaning indicator.
Page 37
Notes on CLEANING FILTER operation
• In this operation, dust is collected in the dust box.
• In an environment where oil or nicotine is attached to the air lter, the lter may not be completely cleaned by the CLEANING FILTER
operation, and you may need to clean the air lter by yourself.
• You can remove the air lters and clean them manually as well. Page 38
• When the indoor temperature is lower than 10°C, the CLEANING FILTER operation will not start to protect the air lters.
• The CLEANING FILTER operation after the “URURU” HUMIDIFY, HUMID HEATING, or FRESH AIR SUPPLY VENTILATION operation
may become longer than usual to protect the air conditioner.
• If the AUTO CLEANING FILTER is set to “Off”, the lter may not be completely cleaned unless you perform the CLEANING FILTER
operation on a daily basis.
• When the MOLD PROOF / CLEANING FILTER lamp blinks, clean the dust box and reset the dust box cleaning indicator.
Page 37
< Relation between CLEANING FILTER operation and the indoor unit lamp >
Air conditioner CLEANING FILTER operation MOLD PROOF / CLEANING FILTER lamp
Operating Automatic “On” Goes out *1 *2
Automatic “Off” Goes out *2
Not operating
Automatic “On”, operating Lights up
Automatic “Off”, operating Lights up
Automatic “On / Off”, not operating Goes out
*1 When AUTO CLEANING FILTER operation is started after the unit has continued to operate for 24 hours or longer, the
MOLD PROOF / CLEANING FILTER lamp will light up.
*2 If the AUTO MOLD PROOF is set to “On”, the lamp will light up.
To keep the air conditioner clean

30
To know the status of your room and air conditioner
INFORMATION
The indicator displayed on the LCD gives information about temperature, power consumption,
and so on.
The indicated indoor and outdoor temperatures are measured near the indoor and outdoor
units.
The indicator should be used as a guide only.
< To see the information >
Direct the remote controller toward the indoor unit and
press .
• Keep directing the remote controller toward the indoor unit for about
2 seconds.
A signal is received from the indoor unit.
• Each time you press the button, the information changes.
LCD example
When the indoor temperature is 30°C during DRY COOLING operation.
Indoor temperature
Indoor humidity
Outdoor
temperature
Current power
consumption
Total power consumption
Notes on INFORMATION
• The total power consumption is displayed up to 9,999kWh. When the total power consumption exceeds 9,999kWh, the indicator shows
0kWh. Also, if the total number of days that the unit is used exceeds 999, the indicator shows 0 days. (The displayed number of days is
the total time that the power to the unit is on.) Please use these indications as a guide.
• The power consumption is displayed in increments of 0.1kWh up to 50kWh and in increments of 1kWh after 50kWh.
• The indoor and outdoor temperatures are indicated by estimating the temperatures near the indoor and outdoor units based on the
temperatures detected by the sensor attached to the indoor and outdoor units.
• If the signals from the remote controller do not properly reach the indoor unit, the setting displayed on the LCD may be different from the
actual operation of the indoor unit. If you press in that condition, the operation of the indoor unit will be changed according to the
setting on the remote controller.
• If is pressed when the outdoor temperature cannot be detected such as when the unit is stopped, the outdoor temperature is
displayed as “--”. In this case, press again.
• Indoor and outdoor temperatures between –9°C and 39°C can be displayed.
Useful Functions

32
No. Menu Setting Description
1
INTELLIG.EYE
AIRFLOW
Focus The INTELLIGENT EYE sensor detects an area where there is a person and adjusts the
horizontal air ow direction to blow air directly on the person.
Comfort * The INTELLIGENT EYE sensor detects an area where there is a person and adjusts the
horizontal air ow direction to avoid blowing air directly on the person.
< Note >
Focus
• The vertical air ow direction is adjusted so that the maximum air ow rate is achieved.
Comfort
• The unit blows air upward in the COOLING operation and downward in the HEATING operation. COOLING
HEATING
2AUTO OFF
time
1 HR *
Sets the time for stopping the operation to after 1 hour or after 3 hours.
• This function is not activated during the following operations.
MOLD PROOF, QUICK HEATING TIMER and
CLEANING FILTER operation
This function will be activated after the end of each operation.
• This function is not totally activated if the 24 HOUR FRESH AIR SUPPLY VENTILATION is
set.
3 HR
< Note >
• This function changes the set temperature +2°C in COOLING / –2°C in HEATING and the operation stops after the preset time
elapses if it is judged that no one is in the room.
• 3 minutes before the operation stops, the OPERATION lamp blinks to lower the air ow rate. After that, the operation stops.
• In this mode, the operation stops automatically. It is recommended to set the AUTO OFF operation to “Off” if a small child or a sick
person is in the room. (If a person does not move much, the sensor judges that no one is in the room and the air conditioner may
be stopped.)
• If the operation has been stopped by AUTO OFF operation, the LCD will not show “OFF.”
3BREEZE
AIRFLOW
Auto * Sets the BREEZE AIRFLOW rate to “Auto”.
Low Sets the BREEZE AIRFLOW rate to “Low”.
< Note >
• This function sets the air ow rate when the vertical air ow direction is set to “BREEZE”.
If you are disturbed by the unit's operating sound, set it to “Low”.
4HUMIDIFY
AIRFLOW
Auto * Sets the humidi ed air ow rate to “Auto”.
High Sets the humidi ed air ow rate to “High”.
Low Sets the humidi ed air ow rate to “Low”.
< Note >
• This function sets the humidi ed air ow rate in the “URURU” HUMIDIFY and HUMID HEATING operations.
To increase the humidi ed air ow rate, set it to “High” and if you are disturbed by the sound of the humidifying operation, set it to
“Low”.
* Default setting
Useful Functions

33
To change the default settings
No. Menu Setting Description
5CONTINUE
DRY
On * CONTINUE DRY operation is performed.
Off CONTINUE DRY operation is not performed.
< Note >
• When the indoor temperature or humidity falls far below the preset value, the fans of indoor and outdoor units are stopped to keep
the room comfortable.
This operation is activated in the COOLING, “SARARA” DRY, and DRY COOLING operations.
• When the CONTINUE DRY is set to “On”, starting the COOLING, “SARARA” DRY, or DRY COOLING operation triggers the
deodorising function which reduces any unpleasant odour coming from the indoor unit and the unit does not blow air for
40 seconds.
• Before the outdoor unit operates, the indoor temperature may be higher than the set temperature.
6INSTALLED
POSITION
*Oblong centre *
The horizontal air ow direction blows air evenly to the right and left.
Oblong right corner
The horizontal air ow direction blows air to the left.
Oblong left corner
The horizontal air ow direction blows air to the right.
Horizontal centre
The horizontal air ow direction blows air evenly to the right and left.
Horizontal right corner
The horizontal air ow direction blows air to the left.
Horizontal left corner
The horizontal air ow direction blows air to the right.
< Note >
• Air ow direction is properly controlled by inputting data on the room shape and installation position of the indoor unit in the remote
controller. Set oblong or horizontal according to the room shape.
•
If you do not set the right corner and left corner correctly, the air ow direction may not be properly controlled in some air ow settings.
• The air ow direction range at the horizontal air ow setting (air ow direction that can be selected with ) will change according
to the settings for the installation position.
< Setting guides >
When the distance is 2 to
50cm, set to the left corner.
When the unit is installed in
the centre, set to centre.
When the distance is 2 to
50cm, set to the right corner.
7
RESET USED
POWER
Reset with
APPLY Resets the total power consumption to 0kWh.
< Note >
• This function resets the total power consumption.
• To check the power consumption, press .
8SOUND
VOLUME
High The volume is high.
Low * Normal volume.
Off The volume is off.
< Note >
• This function sets the volume of the receiving tone of the indoor unit.
* Default setting

34
No. Menu Setting Description
9CONTRAST 1 to 5
• You can set the contrast between 1 and 5.
The default setting is “3”.
• The higher the gure, the darker the indicator.
< Note >
• This function sets the contrast of the LCD.
10 24 HOUR
FRESH AIR
Push APPLY
2sec. On
Starts 24 HOUR FRESH AIR SUPPLY VENTILATION operation.
Push APPLY
2sec. Off *
Stops 24 HOUR FRESH AIR SUPPLY VENTILATION operation.
< Note >
• Even if you stop the air conditioner with the remote controller, it continues ventilation for 24 hours until you change the setting to
“Off”.
• The 24 HOUR FRESH AIR SUPPLY VENTILATION starts itself when the circuit breaker has been turned on.
(The OPERATION lamp of the unit is off during the operation. No display is shown on the remote controller.)
• When the 24 HOUR FRESH AIR SUPPLY VENTILATION is solely operated, the streamer discharge cannot be started.
• When the AUTO CLEANING FILTER is set to “On” and the normal operation of the air conditioner stops for 24 hours or longer, the
24 HOUR FRESH AIR SUPPLY VENTILATION is terminated and the CLEANING FILTER operation starts (and lasts for about 11
minutes). After the lter has been cleaned, the 24 HOUR FRESH AIR SUPPLY VENTILATION restarts. Page 28
11 RC
ADDRESS
Push APPLY
2sec. 1 *
The default setting is “1” for both the indoor unit and remote controller.
< To set the address to “2” >
1. Open the front panel, and turn on the circuit breaker.
2. Press .
3. Press to select “RC ADDRESS” and press .
4. Press to select “2”.
5. Press for 2 seconds and send a signal to the indoor unit. The OPERATION lamp
(green) blinks for about 1 minute. (This is not an error blink.)
6. Press the indoor unit ON/OFF switch while the OPERATION lamp is blinking.
If you cannot set the address while
the OPERATION lamp is blinking,
redo this procedure from the rst step.
Push APPLY
2sec. 2
< Note >
• This function sets the address when you install 2 indoor units in the same room and do not want to operate them with 1 remote
controller.
When you set one of the indoor units and one of the 2 remote controllers to “2”, the set remote controller can send a signal only to
the set indoor unit.
12 CHILD
LOCK
Push APPLY
2sec. On
Press for about 2 seconds to activate the child lock function.
Push APPLY
2sec. Off
Press for about 2 seconds to cancel the child lock function.
< Note >
• This function prevents children from operating the remote controller by mistake.
is displayed and the buttons except is disabled.
* Default setting
Useful Functions

36
CAUTION
• Do not touch the aluminium ns of the indoor unit. (It may cause an injury.)
• Do not use the following to clean the air conditioner. (It may cause deformation, discolouration or scratches.)
– Water hotter than 40°C – Volatile liquid such as benzene, petrol and thinner
– Polishing compound – Rough materials such as scrubbing brush
When?
When the TIMER lamp (orange) blinks or once in a season.
The TIMER lamp blinks to indicate that the streamer unit needs
cleaning when the total operation time of the air conditioner
exceeds 1,800 hours. Clean (Streamer unit cleaning indicator)
the streamer unit.
Streamer discharge is disabled while the lamp is blinking.
How?
1) Soak the streamer unit in lukewarm water or cold water (for
about 1 hour).
2) Use a cotton bud or soft cloth to clean the unit.
(Wear rubber gloves.)
3) Wash the unit with running water and drain it thoroughly.
4) Dry the unit in a well-ventilated shady area (for about 1 day).
Reset the indicator after cleaning.
Turn on the circuit breaker, and press while and then
the air conditioner is not operating. Page 8
• The streamer unit cleaning indicator goes out.
If dust adheres to the needles
Gently wipe the dust from the needles with a soft material such as
a cotton bud, moistened with water or neutral liquid detergent.
When wiping dust off, be careful not to deform the needles.
A deformed needle will lower the deodorisation ability.
Dust Cotton bud
Wipe the needles gently
from the root to the tip.
Removing the streamer unit
Hold the grip of the streamer unit and
pull it toward yourself.
Grip
Streamer unit
Attaching the streamer unit
Insert the streamer unit all the way in.
Attention
• If you cannot remove dirt or dust completely, add neutral
liquid detergent to lukewarm water or cold water and soak
the lter in it.
• Follow the instructions regarding neutral liquid detergent
when you use it. Wash the streamer unit thoroughly with
water after using detergent to remove any residue.
• Be careful not to leave any lint on the streamer unit. (Lint
may cause the unit to malfunction.)
• Do not disassemble the streamer unit.
Streamer unit
Cleaning

37
Cleaning (for service personnel)
Dust box / Dust brush
When?
When the MOLD PROOF / CLEANING FILTER lamp (green)
blinks.
The MOLD PROOF / CLEANING FILTER lamp blinks to indicate
that the dust box needs cleaning when there is dust in the dust
box or when the dust brush gets dirty with the CLEANING FILTER
operation (automatic or manual). ( ) Dust box cleaning indicator
Clean the dust box.
CLEANING FILTER operation cannot be performed while the lamp
is blinking.
How?
• Use a vacuum cleaner to remove dust or wash with water.
• If you have washed the dust box with water, dry it well in the
shade.
Reset the indicator after cleaning.
Turn on the circuit breaker, and press while and then
the air conditioner is not operating. Page 8
• The dust box cleaning indicator goes out.
Removing the dust box
1. Slide the right and left xing tabs
(blue) inwards and slowly pull the
dust box out with both hands.
Fixing tab
Fixing tab Dust box
2. Open the dust box.
2) Turn the cover to open
the dust box.
OPEN
1) Slide the cover (dark grey) to
the direction and release
the lock.
Cover
Cover
Do not direct the
body downward, as
dust is collected
there. Body
< Removing or attaching the dust brush >
1) Pull the centre of the dust brush.
2) Take out the dust brush from the right-side and left-side shaft
holes.
3) Pull out the dust brush.
For installation, attach the dust brush to the shaft holes, and
push it in the dust box.
Dust brush
Shaft hole
Do not touch the
sharp top of the
bristles.
CAUTION
Con rm that the dust brush is securely attached.
Otherwise, the dust brush may not rotate and the
CLEANING FILTER operation may not be performed.
Attaching the dust box
1. Close the dust box, and then slide the
cover to lock the dust box.
OPEN
Slide the cover in
the opposite
direction to .
2. Hold the dust box with both hands
and attach it in the unit so that the
dust brush faces the air conditioner
side.
3. Slide the xing tabs at both ends
outwards.
CLEANING FILTER operation will not be correctly
performed if the tabs are not securely locked.
Produkt Specifikationer
Mærke: | Daikin |
Kategori: | Klimaanlæg |
Model: | FTXZ50NV1B |
Har du brug for hjælp?
Hvis du har brug for hjælp til Daikin FTXZ50NV1B stil et spørgsmål nedenfor, og andre brugere vil svare dig
Klimaanlæg Daikin Manualer

10 April 2025

10 April 2025

10 April 2025

10 April 2025

10 April 2025

10 April 2025

10 April 2025

10 April 2025

10 April 2025

10 April 2025
Klimaanlæg Manualer
- Klimaanlæg Element
- Klimaanlæg Handson
- Klimaanlæg Nedis
- Klimaanlæg Suntec
- Klimaanlæg Inventor
- Klimaanlæg Koldfront
- Klimaanlæg SVAN
- Klimaanlæg Khind
- Klimaanlæg APC
- Klimaanlæg Heiko
- Klimaanlæg Telair
- Klimaanlæg Eldom
- Klimaanlæg D-Let
- Klimaanlæg TecLime
- Klimaanlæg Xiaomi
Nyeste Klimaanlæg Manualer

8 Juni 2025

8 Juni 2025

8 Juni 2025

8 Juni 2025

8 Juni 2025

8 Juni 2025

8 Juni 2025

8 Juni 2025

8 Juni 2025

8 Juni 2025