Little Giant WGFP-100 Manual

Little Giant Pumpe WGFP-100

Læs gratis den danske manual til Little Giant WGFP-100 (8 sider) i kategorien Pumpe. Denne vejledning er vurderet som hjælpsom af 3 personer og har en gennemsnitlig bedømmelse på 3.5 stjerner ud af 2 anmeldelser. Har du et spørgsmål om Little Giant WGFP-100, eller vil du spørge andre brugere om produktet?

Side 1/8
1
ENGLISH
ENGLISH
EN
This instruction sheet provides you with the information required
to safely own and operate your Little Giant pump. Retain these
instructions for future reference.
The Little Giant pump you have purchased is of the highest quality
workmanship and material, and has been engineered to give you
long and reliable service. Little Giant pumps are carefully tested,
inspected, and packaged to ensure safe delivery and operation.
Please examine your pump carefully to ensure that no damage
occurred during shipment. If damage has occurred, please
contact the place of purchase. They will assist you in replacement
or repair, if required.
READ THESE INSTRUCTIONS CAREFULLY BEFORE
ATTEMPTING TO INSTALL, OPERATE, OR SERVICE YOUR
LITTLE GIANT PUMP. KNOW THE PUMP’S APPLICATION,
LIMITATIONS, AND POTENTIAL HAZARDS. PROTECT
YOURSELF AND OTHERS BY OBSERVING ALL SAFETY
INFORMATION. FAILURE TO COMPLY WITH THESE
INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/
OR PROPERTY DAMAGE!
DESCRIPTION
This pump has been designed to operate in applications such
as waterfalls, streams, and fountainheads. It can also be used to
circulate the water in your pond. Unique features of this pump
include a non-clogging vortex impeller, auto-resetting thermal
overload protection, stainless steel motor housing, and the ability
to pass solids with diameters up to 1.18”/30mm (WGFP-50) or
1.38”/35mm (WGFP-75, WGFP-100, WGFP-150, and WGFP-200).
CAUTION: To prevent damaging the pump, do not pump
abrasives such as sand or mud.
SAFETY GUIDELINES
Read all instructions and Safety Guidelines thoroughly. Failure
to follow the guidelines and instructions could result in serious
bodily injury and/or property damage.
RISK OF ELECTRICAL SHOCK: This pump is supplied with a
grounding conductor and grounding-type attachment plug. To
reduce the risk of electric shock, be certain that it is connected
only to a properly grounded, grounding-type receptacle. A
separate branch circuit is recommended. Do not remove the third
prong from the plug.
RISK OF ELECTRICAL SHOCK: This pump has not been certified
for use in swimming pool areas where people are present in the
water. Therefore, pump must not be used for this purpose.
WARNING: Do not use to pump flammable or explosive fluids
such as gasoline, fuel oil, kerosene, etc. Pump should only be
used with liquids compatible with pump component materials.
Failure to follow this warning can result in property damage,
personal injury, or death.
The pump motor is equipped with an automatic resetting thermal
protector and may restart unexpectedly.
Do not handle a pump or pump motor with wet hands or when
standing on a wet or damp surface, or in water. Do not stand
in water while changing fuses or insert your finger into the fuse
socket.
Make certain the unit is disconnected from the power source, all
liquids are drained, and all pressure released within the system
before attempting to service the pump.
This appliance has no user-serviceable parts. The motor housing of
the pump is completely sealed and requires no service. Disassembly
of the motor housing or alteration of the power cord will void all
warranties. The power cord on these units cannot be replaced.
Conformity with local and state electric codes is mandatory. The
National Electric Code requires that a ground fault circuit interrupter
(GFCI) be used in the branch circuit supplying sump, utility, effluent
and all fountain pumps, pool pumps and other pond equipment.
All wiring and electrical work should be done by a qualified electrician.
An acceptable motor control switch shall be provided at the time
of installation.
Secure the discharge line before starting the pump. An unsecured
discharge line will whip, possibly causing personal injury and/or
property damage.
Do not run the pump dry. It is designed to be cooled by the fluid it
moves. If the pump is run dry it will become dangerously hot, and
could cause personal injury and/or damage to the pump.
The pump’s motor housing or gear chamber contains a dielectric
oil to aid in bearing lubrication and motor heat dissipation. This
oil is non-toxic to aquatic life, however suffocation can occur if oil
is left on the water surface. If oil escapes, it can be removed from
the surface quickly by placing newspapers on the water surface to
soak up the oil.
Do not lift or carry the pump by the power cord. Use the handle
on top of the pump.
Adhere to the guidelines of the National Electric Code (NEC) or
Canadian Electric Code (CEC) and any other national, state, and
local electric, plumbing, and building codes for ALL installations.
Check with the appropriate agencies or a water systems
professional for information. The installation of this product must
be in accordance with applicable regulations.
MODELS
MODèLES
MODELOS
WGfp-50 • WGfp-75 •
WGfp-100 • WGfp-150 •
WGFP-200
Franklin Electric Co., Inc.
Oklahoma City, OK
1-888.856.0000 Fax: 1-405.440.1469
www.lg-outdoor.com
customerservice@lgpc.com
MODEL
NO.
CATALOG
NO.
DISCH.
SIZE
HP PH VOLTS HZ AMPS WATTS
WGFP-50 566068 2” FNPT 1/2 1 115 60 7 590
WGFP-75 566069 2” FNPT 3/4 1 115 60 8 847
WGFP-100 566070 2” FNPT 1 1 115 60 12 1210
WGFP-150 566071 3” FNPT 1-1/2 1 115 60 11 1210
WGFP-200 566072 3” FNPT 2 1 230 60 9 2085
Table 1 • Tableau 1 • Tabla 1


Produkt Specifikationer

Mærke: Little Giant
Kategori: Pumpe
Model: WGFP-100

Har du brug for hjælp?

Hvis du har brug for hjælp til Little Giant WGFP-100 stil et spørgsmål nedenfor, og andre brugere vil svare dig




Pumpe Little Giant Manualer

Pumpe Manualer

Nyeste Pumpe Manualer

ProFlo

ProFlo PF92305 Manual

15 December 2025
ProFlo

ProFlo PF92370 Manual

15 December 2025
Liberty Pumps

Liberty Pumps CSP-457 Manual

11 December 2025
ProFlo

ProFlo PF93511 Manual

11 December 2025
ProFlo

ProFlo PF92342 Manual

11 December 2025
Liberty Pumps

Liberty Pumps LE41A Manual

11 December 2025
Vevor

Vevor 2KQ-3G Manual

2 December 2025
Vevor

Vevor TL-A5102 Manual

2 December 2025