Daikin RXF50F5V1B Manual


Læs gratis den danske manual til Daikin RXF50F5V1B (76 sider) i kategorien Ikke kategoriseret. Denne vejledning er vurderet som hjælpsom af 19 personer og har en gennemsnitlig bedømmelse på 4.8 stjerner ud af 10 anmeldelser. Har du et spørgsmål om Daikin RXF50F5V1B, eller vil du spørge andre brugere om produktet?

Side 1/76
Installer reference guide
R32 split series
RXF50F5V1B
Table of contents
Installer reference guide
2
RXF50F5V1B
R32 split series
4P769827-16D – 2024.09
Table of contents
1 About the documentation 4
1.1 About this document...................................................................................................................................................... 4
1.1.1 Meaning of warnings and symbols................................................................................................................ 5
2 General safety precautions 7
2.1 For the installer .............................................................................................................................................................. 7
2.1.1 General........................................................................................................................................................... 7
2.1.2 Installation site............................................................................................................................................... 8
2.1.3 Refrigerant — in case of R410A or R32......................................................................................................... 11
2.1.4 Brine ............................................................................................................................................................... 12
2.1.5 Water ............................................................................................................................................................. 13
2.1.6 Electrical......................................................................................................................................................... 13
2.1.7 Gas.................................................................................................................................................................. 15
2.1.8 Gas exhaust.................................................................................................................................................... 16
2.1.9 Local legislation.............................................................................................................................................. 16
3 Specific installer safety instructions 18
4 About the box 24
4.1 Outdoor unit................................................................................................................................................................... 24
4.1.1 To unpack the outdoor unit........................................................................................................................... 24
4.1.2 To handle the outdoor unit ........................................................................................................................... 24
4.1.3 To remove the accessories from the outdoor unit....................................................................................... 25
5 About the unit 26
5.1 Identification .................................................................................................................................................................. 26
5.1.1 Identification label: Outdoor unit.................................................................................................................. 26
6 Unit installation 27
6.1 Preparing the installation site ........................................................................................................................................ 27
6.1.1 Installation site requirements of the outdoor unit ....................................................................................... 28
6.1.2 Additional installation site requirements of the outdoor unit in cold climates ........................................... 30
6.2 Opening the unit ............................................................................................................................................................ 31
6.2.1 About opening the unit.................................................................................................................................. 31
6.2.2 To open the outdoor unit .............................................................................................................................. 31
6.3 Mounting the outdoor unit............................................................................................................................................ 31
6.3.1 About mounting the outdoor unit................................................................................................................. 31
6.3.2 Precautions when mounting the outdoor unit ............................................................................................. 32
6.3.3 To provide the installation structure............................................................................................................. 32
6.3.4 To install the outdoor unit............................................................................................................................. 33
6.3.5 To provide drainage....................................................................................................................................... 33
6.3.6 To prevent the outdoor unit from falling over.............................................................................................. 34
7 Piping installation 36
7.1 Preparing refrigerant piping........................................................................................................................................... 36
7.1.1 Refrigerant piping requirements ................................................................................................................... 36
7.1.2 Refrigerant piping insulation ......................................................................................................................... 37
7.1.3 Refrigerant piping length and height difference........................................................................................... 37
7.2 Connecting the refrigerant piping.................................................................................................................................. 37
7.2.1 About connecting the refrigerant piping ...................................................................................................... 38
7.2.2 Precautions when connecting the refrigerant piping ................................................................................... 38
7.2.3 Guidelines when connecting the refrigerant piping ..................................................................................... 39
7.2.4 Pipe bending guidelines................................................................................................................................. 40
7.2.5 To flare the pipe end ..................................................................................................................................... 40
7.2.6 Using the stop valve and service port ........................................................................................................... 41
7.2.7 To connect the refrigerant piping to the outdoor unit................................................................................. 42
7.3 Checking the refrigerant piping ..................................................................................................................................... 43
7.3.1 About checking the refrigerant piping .......................................................................................................... 43
7.3.2 Precautions when checking the refrigerant piping....................................................................................... 43
7.3.3 To check for leaks .......................................................................................................................................... 44
7.3.4 To perform vacuum drying ............................................................................................................................ 44
8 Charging refrigerant 46
8.1 About charging refrigerant............................................................................................................................................. 46
8.2 About the refrigerant ..................................................................................................................................................... 47
8.3 Precautions when charging refrigerant ......................................................................................................................... 48
8.4 To determine the additional refrigerant amount.......................................................................................................... 48


Produkt Specifikationer

Mærke: Daikin
Kategori: Ikke kategoriseret
Model: RXF50F5V1B

Har du brug for hjælp?

Hvis du har brug for hjælp til Daikin RXF50F5V1B stil et spørgsmål nedenfor, og andre brugere vil svare dig