Table of contents
Installer reference guide
2
RXTM-R_RXTP-R_ARXTP-R_RXTA-B
R32 split series
4P518023-11H – 2021.03
Table of contents
1 About the documentation 4
1.1 About this document ...................................................................................................................................................... 4
1.1.1 Meaning of warnings and symbols ................................................................................................................ 5
2 General safety precautions 7
2.1 For the installer............................................................................................................................................................... 7
2.1.1 General ........................................................................................................................................................... 7
2.1.2 Installation site ............................................................................................................................................... 8
2.1.3 Refrigerant — in case of R410A or R32.......................................................................................................... 11
2.1.4 Electrical ......................................................................................................................................................... 12
3 Specific installer safety instructions 15
4 About the box 21
4.1 Overview: About the box................................................................................................................................................ 21
4.2 Outdoor unit ................................................................................................................................................................... 21
4.2.1 To unpack the outdoor unit ........................................................................................................................... 21
4.2.2 To handle the outdoor unit............................................................................................................................ 21
4.2.3 To remove the accessories from the outdoor unit........................................................................................ 22
5 About the unit 23
5.1 Identification ................................................................................................................................................................... 23
5.1.1 Identification label: Outdoor unit .................................................................................................................. 23
6 Unit installation 24
6.1 Preparing the installation site......................................................................................................................................... 24
6.1.1 Installation site requirements of the outdoor unit........................................................................................ 25
6.1.2 Additional installation site requirements of the outdoor unit in cold climates............................................ 27
6.2 Opening the unit ............................................................................................................................................................. 28
6.2.1 About opening the unit .................................................................................................................................. 28
6.2.2 To open the outdoor unit............................................................................................................................... 28
6.3 Mounting the outdoor unit............................................................................................................................................. 28
6.3.1 About mounting the outdoor unit ................................................................................................................. 28
6.3.2 Precautions when mounting the outdoor unit.............................................................................................. 29
6.3.3 To provide the installation structure ............................................................................................................. 29
6.3.4 To install the outdoor unit ............................................................................................................................. 30
6.3.5 To provide drainage........................................................................................................................................ 30
6.3.6 To prevent the outdoor unit from falling over .............................................................................................. 30
7 Piping installation 32
7.1 Preparing refrigerant piping ........................................................................................................................................... 32
7.1.1 Refrigerant piping requirements.................................................................................................................... 32
7.1.2 Refrigerant piping insulation.......................................................................................................................... 33
7.1.3 Refrigerant piping length and height difference ........................................................................................... 33
7.2 Connecting the refrigerant piping .................................................................................................................................. 33
7.2.1 About connecting the refrigerant piping ....................................................................................................... 33
7.2.2 Precautions when connecting the refrigerant piping.................................................................................... 34
7.2.3 Guidelines when connecting the refrigerant piping ...................................................................................... 35
7.2.4 Pipe bending guidelines ................................................................................................................................. 36
7.2.5 To flare the pipe end ...................................................................................................................................... 36
7.2.6 Using the stop valve and service port............................................................................................................ 36
7.2.7 To connect the refrigerant piping to the outdoor unit ................................................................................. 38
7.3 Checking the refrigerant piping ...................................................................................................................................... 38
7.3.1 About checking the refrigerant piping........................................................................................................... 38
7.3.2 Precautions when checking the refrigerant piping........................................................................................ 39
7.3.3 To check for leaks........................................................................................................................................... 39
7.3.4 To perform vacuum drying............................................................................................................................. 40
8 Charging refrigerant 42
8.1 About charging refrigerant ............................................................................................................................................. 42
8.2 About the refrigerant...................................................................................................................................................... 43
8.3 Precautions when charging refrigerant.......................................................................................................................... 44
8.4 To determine the additional refrigerant amount .......................................................................................................... 44
8.5 To determine the complete recharge amount .............................................................................................................. 44
8.6 To charge additional refrigerant..................................................................................................................................... 44
8.7 To fix the fluorinated greenhouse gases label ............................................................................................................... 45