Dimplex FX20V Manual


Læs gratis den danske manual til Dimplex FX20V (3 sider) i kategorien Varmeapparat. Denne vejledning er vurderet som hjælpsom af 31 personer og har en gennemsnitlig bedømmelse på 5.0 stjerner ud af 16 anmeldelser. Har du et spørgsmål om Dimplex FX20V, eller vil du spørge andre brugere om produktet?

Side 1/3
Contact Details
Pleasenotethat some contact ofthe details on 
thisPDFdocumentmaynotbe current.
Pleaseuse  the following detailsifyouneedto
contactus:
Telephone:0844 879 3588
Email:customer.services@gdcgroup.co.uk
The widecustomer alsosupportsection websiteofour  features a
rangeof ofinformationwhichmaybe use availabletoyouandis 
24 ahours day.Itincludes:
Operating  and installation instructions
Easy   ‘How to use’ guides for storage heaters
Service  and repairs
Wheretobuyourproducts
Literature downloads
Heating  requirement calculator
 ‐Visit www.dimplex.co.uk/support
A division of GDC Group Ltd
Millbrook House Grange Drive Hedge End Southampton SO30 2DF
www.dimplex.co.uk
Re
g
istered No: 1313016 En
g
land
VAT GB 287 1315 50004
EEE Producer Registration Number
WEE/GE0057TS
Paper from sustainable sources
Downflow Fan Heater
Model : FX 20V
Installation and Operating Instructions
Dimensions
(millimetres)
Model(s) Specification
FX 20V (High Level) 1/2kw + Adjustable Thermostat (internal by installer)
Fig. 1
(IP22)
IMPORTANT SAFETY
ADVICE
WARNING - DO NOT USE THIS HEA
TER IN THE IMMEDIATE
SURROUNDINGS OF A BATH, A SHOWER OR
A SWIMMING POOL.
DO NOT COVER THE APPLIANCE or place material or garments
on it, or obstruct the air circulation around this appliance, for
example with curtains or furniture, as this could cause
overheating and a fire risk.
DO NOT PLACE AEROSOLS OR OTHER CONTAINERS
SUSCEPTIBLE TO HEAT IN THE DIRECT AIRFLOW FROM THE UNIT.
THIS HEATER MUST NOT BE LOCATED IMMEDIATELY BELOW A
FIXED SOCKET OUTLET.
WARNING: Do not operate the heater with the top cover removed.
The appliance is not intended for use by children or other persons
without assistance or supervision if their physical, sensory or
mental capabilities prevent them from using it safely. Children
should be supervised to ensure that they do not play with the
appliance.
WARNING DISCONNECT THE HEATER FROM THE ELECTRICITY
SUPPLY BEFORE UNDERTAKING SERVICE OR REPAIR.
WARNING If the appliance is fitted in a bathroom, a cable outlet
will be necessary with the supply to the unit controlled by a
double pole switch. The switch if inside the bathroom should be
pull cord operated and if outside should be adjacent to the
entrance door. The appliance must be mounted so that no part of
it can be touched by any person using bath or shower.
THIS HEATER MUST NOT BE OPERATED WITHOUT THE COVER
CORRECTLY IN POSITION.
Warning : In order to avoid a hazard due to inadvertent resetting of
the thermal cutout, this appliance must not be supplied through an
external switching device, such as a timer, or connected to a
circuit that is regularly switched on and off by the utility.
General
The heater has a loading of 2KW. It is designed for permanent wall mounting
and is suitable for operation on A.C. electricity supply having the same
voltage as shown on the rating label.
The heater is fitted with an internally mounted selector switch which on
installation of the heater allows a choice of 1kW or 2kW output to suit the
dimensions of the room to be heated.
In rooms of less than 9 – 11 cubic m. (350 - 400 cubic ft.) 1kW output should
be selected, otherwise nuisance tripping of the thermal overload cut-out
may occur.
NOTE : THE SWITCH HAS BEEN FACTORY SET FOR 1kW OPERATION.
IF ADDITIONAL OUTPUT IS REQUIRED, 2kW CAN BE SELECTED ON
INSTALLATION.
SUPPLY CABLE IS NOT SUPPLIED WITH THIS APPLIANCE AND IT
SHOULD THEREFORE BE INSTALLED BY A COMPETENT ELECTRICIAN
IN ACCORDANCE WITH THE LATEST IEE REGULATIONS.
08/15981/6 Issue 6
THESE INSTRUCTIONS SHOULD BE READ CAREFULLY AND RETAINED FOR FUTURE REFERENCE
Controls
The cut-out is a safety device which switches off the heater and fan if for
any reason the appliance overheats - see ‘Safety’.
The thermal fuse link is provided as an added safety feature, and operates
to open circuit if there is abnormal overheating within the appliance. The
operation of these safety devices is described under Safety’.
The pull cord switch operates the ON/OFF switch. (An indicator light
illuminates to show when the heater is ON and does not illuminate when
the heater is OFF) .
The heater is fitted with an adjustable thermostat, which has three different
settings : 1. - Low, 2. - Medium, 3 - High. This gives you an approximate
room temperature range of 18°C - 32°C depending on room size. If internal
switch is set to 2kW, the temperature switches to half heat when the room
warms up. Full heat will be switched on automatically when the room
temperature falls. This can be adjusted by installer, by removing top cover.
The thermostat will only function when 2KW is selected. The thermostat
has been factory set on ‘2’ (Medium).
To adjust the thermostat setting or reset selector switch first remove the top
cover, then adjust thermost
at to required setting, or reset selector switch to
1kW or 2kW as required, then refit top cover. Do not operate the unit with
the top cover removed.
Safety
Cut-Out
For your safety, this appliance is fitted with a thermal cut-out. In the event
that the product overheats, the cut-out switches the heater off automatically.
To bring the heater back into operation, remove the cause of overheating,
then turn off the electrical supply to the heater for a few minutes.
When the heater has cooled sufficiently reconnect and switch on the heater.
Fuse Link
A thermal fuse link is provided as an added safety feature. If the fuse link
operates and opens circuit it is the result of abnormal overheating within
the appliance, and servicing of the appliance by a competent service
engineer will be required in order to ensure the future safe operation of the
heater. Dimplex Customer Services should be contacted (see “After Sales
Service” for details), who will arrange the replacement of any faulty parts
and the fitting of a new fuse link.
Installation
WARNING: Minimum clearences must be adhered to when mounting
the heater.
Before undertaking installation work, ensure the electricity supply is
disconnected from any relevant fixed wiring. Supply cable is not supplied
with this appliance and it should therefore be installed by a competent
electrician in accordance with the latest IEE wiring regulations.
The supply circuit must be adequate for the input of the appliance and
must be protected with a 13A fuse.
A suitable termination to the fixed wiring of the premises must be provided
adjacent to the final position of the appliance through a double pole
switch having a contact separation of at least 3mm in all poles.
250 229
242
109300
MIN
1800
600
MIN
MIN
MIN
floor
ceiling
shelf


Produkt Specifikationer

Mærke: Dimplex
Kategori: Varmeapparat
Model: FX20V
Type: Radiator/ventilator
Tænd-/slukkontakt: Ja
Justerbar termostat: Ingen
Varmeevne: 2000 W
Bredde: 229 mm
Dybde: 109 mm
Højde: 242 mm
Vægt: 1100 g
Velegnet til: Indendørs
Placeringsmuligheder: Væg
Produktfarve: Hvid
Strøm: 2000 W
Indikatorlampe: Ja
Kan monteres på væggen: Ja
Varmekilde: Elektrisk
Velegnet til badeværelse: Ja

Har du brug for hjælp?

Hvis du har brug for hjælp til Dimplex FX20V stil et spørgsmål nedenfor, og andre brugere vil svare dig




Varmeapparat Dimplex Manualer

Dimplex

Dimplex DX 521 Manual

13 Januar 2025
Dimplex

Dimplex VFE 20 Manual

13 Januar 2025
Dimplex

Dimplex VFE 30 Manual

13 Januar 2025
Dimplex

Dimplex Mini Cube Manual

30 December 2025
Dimplex

Dimplex DX 425E Manual

30 December 2025
Dimplex

Dimplex DTD4T Manual

30 December 2025
Dimplex

Dimplex MPH500 Manual

8 Oktober 2024
Dimplex

Dimplex ECOT4FT Manual

8 Oktober 2024
Dimplex

Dimplex FUTM2CE Manual

4 Oktober 2024
Dimplex

Dimplex VFM60HY Manual

4 Oktober 2024

Varmeapparat Manualer

Nyeste Varmeapparat Manualer

Lavex

Lavex 761AMLV75 Manual

15 Juni 2025
XPower

XPower A-12 Manual

15 Juni 2025
BEKO

BEKO RHO8323BT Manual

14 Juni 2025
XPower

XPower B-55 Manual

14 Juni 2025
XPower

XPower B-2 Manual

14 Juni 2025
XPower

XPower M-27 Manual

14 Juni 2025